BBBMF - REVERSAL COM-PAK FIRST DEVELOPER 1
- MSDS: BBBMF
- Manufacturer: FR CHEMICALS DIV OF CINE MAGNETICS
- Product Name: REVERSAL COM-PAK FIRST DEVELOPER 1
- National Stock Number: 6750-00B060001
Product Identification
Product ID:REVERSAL COM-PAK FIRST DEVELOPER 1
MSDS Date:01/01/1987
FSC:6750
NIIN:00B060001
MSDS Number: BBBMF
Responsible Party
MT. VERNON, NY 10550
US
Emergency Phone: 914 667-1002
Info Phone: 914 667-1002
Cage: DO855
Contractor
Telephone: 914 667-1002
Cage: DO855
Ingredients
HYDROQUINONE (SARA III)
CAS: 123-31-9
RTECS: MX3500000
Fraction By Weight: 5.0%
OSHA PEL 2 MG/M3
ACGIH TLV: 2 MG/M3; 9192
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
SODIUM THIOCYANATE
CAS: 540-72-7
RTECS: WE5600000
Fraction By Weight: 1.0%
SODIUM SULFITE
CAS: 7757-83-7
RTECS: WE2150000
Fraction By Weight: 10%.
CAUSTIC SODA
CAS: 1310-73-2
Fraction By Weight: 3.0%
OSHA PEL 2 MG/M3
ACGIH TLV: C 2 MG/M3; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Effects of Overexposure:MAY CAUSE EYE AND SKIN IRRITATION
First Aid
First Aid:EYE-FLUSH IMMEDIATELY WITH PLENTY OF WATER FOR 15 MIN.CALL
PHYSICIAN.SKIN:FLUSH WITH WATER.
Fire Fighting
Flash Point:NONE
Extinguishing Media:NOT FLAMMABLE
Fire Fighting Procedures:NONE
Unusual Fire/Explosion Hazard:NONE
Accidental Release
Spill Release Procedures:FLUSH TO CHEMICAL SEWER WITH WATER.
Handling
Handling and Storage Precautions:AVOID CONTACT WITH EYES,SKIN AND
CLOTHING.
Other Precautions:DO NOT TAKE INTERNALLY.
Exposure Controls
Ventilation:PROVIDE ADEQUATE VENTILATION.
Protective Gloves:MAY BE WORN
Eye Protection:SAFETY GOGGLES
Supplemental Safety and Health
Chemical Properties
Spec Gravity:1.115
pH:11.84
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR,ODORLESS SOLUTION
Stability
Stability Indicator/Materials to Avoid:YES
Disposal
Waste Disposal Methods:FLUSH TO CHEMICAL OR INDUSTRIAL PROCESS SEWER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.