BBBYB - SIMONIZ (R) CHROME CLEANER

  • MSDS: BBBYB
  • Manufacturer: UNION CARBIDE
  • Product Name: SIMONIZ (R) CHROME CLEANER
  • National Stock Number: 7930-00B210004
Product Identification

Product ID:SIMONIZ (R) CHROME CLEANER
MSDS Date:04/01/1986
FSC:7930
NIIN:00B210004
MSDS Number: BBBYB

Responsible Party
UNION CARBIDE
DANBURY, CT 06817
US

Emergency Phone: 1-800-UCC-HELP

Info Phone: 822-4357

Cage: 07098

Contractor
UNION CARBIDE
EAST HARTFORD, CT 06108 US

Telephone: 800-822-4357

Cage: 07098

Ingredients

KEROSENE

CAS: 8008-20-6

RTECS: OA5500000

ACGIH TLV: 500 PPM


DIATOMACEOUS SILICA

CAS: 7361-86-9


AMMONIUM HYDROXIDE (SARA III)

CAS: 1336-21-6

RTECS: BQ9625000

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


OXALIC ACID

CAS: 144-62-7

RTECS: RO2450000

OSHA PEL 1 MG/M3/2 STEL

ACGIH TLV: 1 MG/M3/2 STEL; 9192

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Health Hazards Acute and Chronic:IF SWALLOWED HAS LITTLE ACUTE
TOXICITY.NAUSEA AND VOMITING MAY OCCUR.ASPIRATION INTO THE LUNGS
MAY OCCUR DURING INGESTION OR VOMITING RESULTING IN LUNG INJURY.IF
INHALED DIZZINESS,DROWSINESS,WEAKNESS, DIFFICULTY IN WALKING AND
COMA.SKIN CONTACT CAUSES MINOR IRRITATION,SEEN AS LOCAL
REDNESS,WITH DRYNESS AND CRACKING.
Effects of Overexposure:EYE CONTACT MAY CAUSE EYE DISCOMFORT WITH
EXCESS TEAR PRODUCTION,EXCESS BLINKING,REDDENING OF THE
CONJUNCTIVA.
Medical Cond Aggravated by Exposure:BECAUSE OF ITS IRRITATING AND
DEFATTING PROPERTIES,THIS MATERIAL MAY AGGRAVATE AN EXISTING SKIN
CONDITION.

First Aid

First Aid:DO NOT INDUCE VOMITING.SEEK MEDICAL ATTENTION,IF
SWALLOWED.FOR SKIN CONTACT REMOVE CONTAMINATED CLOTHING AND WASH
SKIN THOROUGHLY WITH SOAP AND WATER.FOR EYE CONTACT IMMEDIATELY
FLUSH EYES WITH PLENTY OF WATER FOR AT LEAST 15 MIN.IF INHALED
REMOVE TO FRESH AIR.IF BREATHING HAS STOPPED,ADMINISTER ARTIFICIAL
RESPIRATION.IF BREATHING IS DIFFICULT GIVE OXYGEN.SEEK MEDICAL
ATTENTION.

Fire Fighting

Flash Point:192F TOC
Extinguishing Media:WATER SPRAY,DRY CHEMICAL,ALCOHOL FOAM,OR CARBON
DIOXIDE
Fire Fighting Procedures:FOR FIRE FIGHTING,USE NIOSH/MSHA APPROVED
SELF-CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:AT FIRE TEMPERATURES DECOMPOSITION
PRODUCTS MAY INCLUDE CARBON MONOXIDE AND CARBON
DIOXIDE.INCOMPATIBLE WITH HIGHLY OXIDIZING CHEMICALS.

Accidental Release

Spill Release Procedures:WEAR APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT
AND REMOVE ALL SOURCES OF IGNITION.COLLECT MATERIAL FOR DISPOSAL IN
A CONTAINER SUITABLE FOR FLAMMABLE WASTE.

Handling

Handling and Storage Precautions:AVOID PROLONGED INHALATION OF
FUMES.KEEP AWAY FROM EXCESSIVE HEAT AND OPEN FLAME.

Exposure Controls

Respiratory Protection:NONE REQUIRED FOR NORMAL USE.FOR OPERATIONS
WHERE PEL MAY BE EXCEEDED USE NIOSH/MSHA APPROVED SELF-CONTAINED
BREATHING APPARATUS.
Ventilation:GENERAL VENTILATION IS ADEQUATE FOR NORMAL HANDLING.WHERE
PEL MAY BE EXCEEDED,LOCAL EXHAUST VENTILATION IS RECOMMENDED.
Protective Gloves:NEOPRENE GLOVES FOR BULK HANDLING.
Eye Protection:CHEMICAL SAFETY GOGGLES
Other Protective Equipment:EYE WASH,SAFETY SHOWER
Supplemental Safety and Health

Chemical Properties

Boiling Pt:B.P. Text:760 MM HG,F
Vapor Pres:MM HG 68F
Vapor Density:AIR=1
Evaporation Rate & Reference:BUTYL ACETATE=1
Solubility in Water:% BY WT.
Appearance and Odor:CHARACTERISTIC,AMMONIATED

Stability

Stability Indicator/Materials to Avoid:YES
HIGHLY OXIDIZING CHEMICALS
Hazardous Decomposition Products:IN CASE OF FIRE,MAY FORM CARBON
MONOXIDE AND CARBON DIOXIDE

Disposal

Waste Disposal Methods:WASTE MATERIAL IS A RCRA HAZARDOUS WASTE DUE TO
IGNITABILITY.INCINERATION OR LANDFILLING SHOULD BE CARRIED OUT IN
ACCORDANCE WITH APPLICABLE RCRA FEDERAL,STATE AND LOCAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.