BBDQK - #4594867 CALIBRATING GAS : CO/AIR

  • MSDS: BBDQK
  • Manufacturer: NATIONAL DRAEGER INC
  • Product Name: #4594867 CALIBRATING GAS : CO/AIR
  • National Stock Number: 6810-00D000971
Product Identification

Product ID:#4594867 CALIBRATING GAS : CO/AIR
MSDS Date:01/01/1987
FSC:6810
NIIN:00D000971
MSDS Number: BBDQK

Responsible Party
NATIONAL DRAEGER,INC.
101 TECHNOLOGY DRIVE
PITTSBURGH, PA 15230
US

Emergency Phone: 412-787-8383

Cage: 53833

Contractor
NATIONAL DRAEGER INC
PITTSBURGH, PA 15372 US

Telephone: 412-787-8383 OR 412-787-8389

Cage: 53833

Ingredients

CARBON MONOXIDE

CAS: 630-08-0

RTECS: FG3500000

Fraction By Weight: <3%

OSHA PEL 50 PPM

ACGIH TLV: 25 PPM; 9293

Hazards

Effects of Overexposure:CO CAUSES OXYGEN STARVATION OF BODY
CELLS;HEADACHE,MENTAL DULLNESS,DIZZINESS,POSSIBLE COLLAPSE,DEATH

First Aid

First Aid:REMOVE VICTIM FROM AREA OF EXPOSURE.RESTORE BREATHING IF
NECESSARY AND ADMINISTER OXYGEN,GET IMMEDIATE MEDICAL ATTENTION.

Fire Fighting

Extinguishing Media:USE WHAT IS APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:COOL CONTR W. WATER. APPLY FROM DISTANCE.
AVOID END OF TK.
Unusual Fire/Explosion Hazard:DO NOT EXPOSE TO HEAT OR FLAMES.

Accidental Release

Spill Release Procedures:VENTILATE AREA.REMOVE LEAKING CYLINDER TO
EXHAUST HOOD OR SAFE OUTDOORS AREA.ELIMINATE SOURCES OF IGNITION.

Handling

Handling and Storage Precautions:STORE CYLINDERS IN A WELL VENTILATED
AREA.RETURN CYLINDERS WITH POSITIVE PRESSURE.
Other Precautions:MOVE CYLINDER WITH AN ADEQUATE HAND TRUCK.IF
METHYLENE CHLORIDE & CO EXPOSURES OCCUR FOR THE SAME WORKERS,THE
LEVELS OF BOTH MUST BE CONTROLLED BELOW TLV LEVELS.

Exposure Controls

Respiratory Protection:S.C.B.A.
Ventilation:EXPLOSION-PROOF LOCAL EXHAUST.
Protective Gloves:NONE
Eye Protection:SAFETY GLASSES
Other Protective Equipment:SAFETY SHOES.
Supplemental Safety and Health
MSDS DATED 1-9-86.

Chemical Properties

HCC:G3
Vapor Density:1
Solubility in Water:1.87 VOL %.
Appearance and Odor:COLORLESS,ODORLESS GAS

Stability

Stability Indicator/Materials to Avoid:YES
NONE
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:NONE

Disposal

Waste Disposal Methods:ALLOW GAS TO DISCHARGE AT A SLOW RATE.RETURN
DEFECTIVE CYLINDER TO SUPPLIER.WASTE CO CAN BE PIPED TO AN APPROVED
INCINERATOR TO BURN CO TO CO*2 UNDER CONTROLLED CONDITIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.