BBFLZ - KODAK HYPO CLEARING AGENT; #123 9060

  • MSDS: BBFLZ
  • Manufacturer: EASTMAN KODAK COMPANY
  • Product Name: KODAK HYPO CLEARING AGENT; #123 9060
  • National Stock Number: 6750-00D001817
Product Identification

Product ID:KODAK HYPO CLEARING AGENT; #123 9060
MSDS Date:06/27/1989
FSC:6750
NIIN:00D001817
MSDS Number: BBFLZ

Responsible Party
EASTMAN KODAK COMPANY
343 STATE STREET
ROCHESTER, NY 14650
US

Emergency Phone: 716-722-5151

Info Phone: 716-722-5151

Cage: 19139

Contractor
EASTMAN KODAK CO GOVERNMENT MARKETS CONTRACTS
ROCHESTER, NY 14650-1115 US

Telephone: 716-722-5151/(800) 242-2424

Cage: 19139

Ingredients

SODIUM SULFITE

CAS: 7757-83-7

RTECS: WE2150000

Fraction By Weight: 75-80%


SODIUM METABISULFITE

CAS: 7681-57-4

RTECS: UX8225000

Fraction By Weight: 15-20%

OSHA PEL 5 MG/M3

ACGIH TLV: 5 MG/M3; 9192


TETRASODIUM ETHYLENE DIAMINE TETRAACETATE

CAS: 64-02-8

RTECS: AH5075000

Fraction By Weight: 1-5%


SODIUM CITRATE

CAS: 68-04-2

RTECS: GE8300000

Fraction By Weight: 1-5%

Hazards

LD50 LC50 Mixture:LD50 (ORAL RAT) IS >1600 MG/KG
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: LOW HAZARD FOR RECOMMENDED
HANDLING. EYES: NO SPECIFIC HAZARD KNOWN. MAY CAUSE TRANSIENT
IRRITATION. SKIN: LOW HAZARD FOR RECOMMENDED HANDLING. INGESTION:
EXPECTED TO BE A LOW HAZARD.
Explanation of Carcinogenicity:NONE OF THE COMPOUNDS IN THIS PRODUCT IS
LISTED BY IARC, NTP, OR OSHA AS A CARCINOGEN.
Effects of Overexposure:MAY CAUSE TRANSIENT IRRITATION OF THE EYES.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHALATION: REMOVE TO FRESH AIR. EYES:IMMEDIATELY FLUSH WITH
PLENTY OF WATER FOR 15 MINUTES HOLDING EYELIDS OPEN. SKIN: WASH
WITH SOAP AND WATER. INGESTION: DRINK 1-2 GLASSES OF WATER. SEEK
MEDICAL AT TENTION.

Fire Fighting

Flash Point:NONCOMBUSTIBLE
Extinguishing Media:USE APPROPRIATE AGENT FOR SURROUNDING FIRE.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE.
Unusual Fire/Explosion Hazard:FIRE OR EXCESSIVE HEAT MAY CAUSE
PRODUCTION OF HAZARDOUS DECOMPOSITION PRODUCTS.

Accidental Release

Spill Release Procedures:FLUSH TO AN ACID-FREE SEWER WITH LARGE AMOUNTS
OF WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CONTAINER TIGHTLY CLOSED AND AWAY
FROM ACIDS OR BASES.
Other Precautions:WASH THOROUGHLY AFTER HANDLING.

Exposure Controls

Respiratory Protection:IF VENTILATION DOES NOT MAINTAIN INHALATION
EXPOSURES BELOW PEL(TLV), USE NIOSH/MSHA APPROVED ORGANIC VAPOR
CARTRIDGE AND DUST/MIST PRE-FILTER RESPIRATORS AS PER CURRENT 29
CFR 1910.134, INSTRUCTIONS/ WARNINGS AND NIOSH-RESPIRATOR
SELECTION.
Ventilation:GOOD GENERAL VENTILATION SHOULD BE SUFFICIENT.
Protective Gloves:NONE
Eye Protection:SAFETY GOGGLES WITH OPTIONAL FACE SHIELD
Other Protective Equipment:NONE
Work Hygienic Practices:OBSERVE GOOD PERSONAL HYGIENE PRACTICES AND
RECOMMENDED PROCEDURES. DO NOT WEAR CONTAMINATED CLOTHING OR
FOOTWEAR.
Supplemental Safety and Health
NONE

Chemical Properties

HCC:N1
Vapor Pres:NEG
Spec Gravity:>1
Evaporation Rate & Reference:NEG (BUTYL ACETATE=1)
Solubility in Water:APPRECIABLE
Appearance and Odor:POWDER, ODORLESS
Percent Volatiles by Volume:NEG

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS AND STRONG BASES.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY PRODUCE
OXIDES OF SULFUR.

Disposal

Waste Disposal Methods:DISCHARGE, TREATMENT, OR DISPOSAL SHOULD BE MADE
IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL LAWS AND
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.