BCCCY - 186 8637, PREHARDNER,PROCESS E-4, PART B

  • MSDS: BCCCY
  • Manufacturer: EASTMAN KODAK COMPANY
  • Product Name: 186 8637, PREHARDNER,PROCESS E-4, PART B
  • National Stock Number: 6750-00K001059
Product Identification

Product ID:186 8637, PREHARDNER,PROCESS E-4, PART B
MSDS Date:05/30/1985
FSC:6750
NIIN:00K001059
Kit Part:Y
MSDS Number: BCCCY

Responsible Party
EASTMAN KODAK COMPANY
343 STATE STREET
ROCHESTER, NY 14650
US

Emergency Phone: 716-722-5151

Info Phone: 716-722-5151

Cage: 19139

Contractor
EASTMAN KODAK CO GOVERNMENT MARKETS CONTRACTS
ROCHESTER, NY 14650-1115 US

Telephone: 716-722-5151/(800) 242-2424

Cage: 19139

Ingredients

FORMALDEHYDE (SARA III)

CAS: 50-00-0

RTECS: LP8925000

Fraction By Weight: 12.5%

OSHA PEL SEE 1910.1048

ACGIH TLV: C 0.3 PPM; A2; 9293

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


METHYL ALCOHOL (METHANOL) (SARA III)

CAS: 67-56-1

RTECS: PC1400000

Fraction By Weight: <5.0%

OSHA PEL S,200PPM/250STEL

ACGIH TLV: S,200PPM/250STEL; 93

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ACETIC ACID (SARA III)

CAS: 64-19-7

RTECS: AF1225000

Fraction By Weight: 07.5%

OSHA PEL 10 PPM

ACGIH TLV: 10 PPM/15 STEL; 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


WATER (75-80)

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 77.5%

Hazards

LD50 LC50 Mixture:LD50 = 800 MG/KG (RAT)
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Explanation of Carcinogenicity:FORMALDEHYDE IS LISTED AS A CARCINOGEN
BY ALL OF 3 ABOVE AGENCIES.
Effects of Overexposure:INH:VAP CAUSES IRRIT;EYES:LIQ/VAP CAUSES
IRRIT;SKIN:PROLNGD/REPEATD LIQ CONTCT CAUSES IRRIT/ALLERGY.

First Aid

First Aid:INH:REMOVE FROM EXPOSURE.GIVE CPR/OXY IF NEEDED & GET MED
ATTN;EYES:FLUSH IMMED W/WATER FOR AT LEAST 15 MIN.GET MED
HELP;SKIN:FLUSH IMMED W/PLENTY OF WATER FOR 15 MIN.FOR BURNS GET
MED ATTN.

Fire Fighting

Flash Point Method:PMCC
Flash Point:185F/85C
Extinguishing Media:CO*2,DRY CHEM,WATER
Fire Fighting Procedures:USE SELF-CONTND BRTHG APP;COOL EXPSD CONT
W/WATER SPRAY
Unusual Fire/Explosion Hazard:SPILL/RUNOFF MAY CAUSE POLLUTION,FIRE OR
EXPLOSION HAZARD.

Accidental Release

Spill Release Procedures:ELIM IGN SOURCES.USE PROTECTV EQUIP,PROVIDE
VENT.STOP LEAK W/O RISK.DIKE LG SPILL & PUMP INTO COVRD
DRUMS;ABSORB/CONTAIN SMALL SPILL IN CONTNR PENDING DISPOSL;MFR
RECOMMENDS,NEUTRLZ W/SOD BICARBONATE THEN FLUSH TO SEWER W/LG AMT
H*2O IAW EXISTG REGS.

Handling

Handling and Storage Precautions:STORE IN COOL,DRY,WELL VENTILATED
AREA.KEEP CONTNRS TIGHTLY CLOSED.PROTECT CONTNRS FROM PHYSICAL
DAMAGE.
Other Precautions:AVOID PROLONGED/REPEATED CONTACT W/PRODUCT.REMOVE &
WASH CONTAMINATED CLOTHING.WASH HANDS AFTER USE.APPROX PH OF
PRODUCT:3.5

Exposure Controls

Respiratory Protection:NONE REQD IN NORMAL CONDITIONS.
Ventilation:MECHANICAL(GEN)/LOCAL EXHAUST SUGGESTED BY MANUFACTURER
Protective Gloves:IMPERVIOUS/RUBR
Eye Protection:SAFETY GLASSES/GOGGLES
Other Protective Equipment:AS NECESSARY TO PREVENT SKIN CONTACT.
Supplemental Safety and Health
KEY1:C3. THIS IS PART B OF A TWO PART KIT. THIS PRODUCT HAS A KODAK
SOLUTION NUMBER:3884.

Chemical Properties

HCC:C3
Boiling Pt:B.P. Text:>212F/>100C
Vapor Pres:32
Vapor Density:0.78
Spec Gravity:1.06
pH:5.3
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS LIQUID,FORMALDEHYDE ODOR.
Percent Volatiles by Volume:99%

Stability

Stability Indicator/Materials to Avoid:YES
PER MFR:STRONG ALKALIS;HOWEVER KEEP AWAY FM FLAMM/OXIDZERS
Hazardous Decomposition Products:CO,CO*2,ETC.

Disposal

Waste Disposal Methods:KEEP IN COVERD CONTNRS PENDING DISPOSAL.SHIP
WASTE TO NEUTRALZNG/DISPOSAL AREA IAW DOT/EPA REGS.HANDLE/DISPOSE
OF IAW FED,STATE/LOCAL REGS;MFR SUGGESTS:NEUTRALZ W/SODIUM
BICARBONATE THEN FLUSH TO SEWE R W/LG AMT H*2O.FED STATE/LOCAL LAWS
TAKE PRECDNCE

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.