BCCLC - 01-R-21 BASE,RED 1186B,STENCIL ENAMEL

  • MSDS: BCCLC
  • Manufacturer: DEFT CHEMICAL COATINGS
  • Product Name: 01-R-21 BASE,RED 1186B,STENCIL ENAMEL
  • National Stock Number: 8010-00K001225
Product Identification

Product ID:01-R-21 BASE,RED 1186B,STENCIL ENAMEL
MSDS Date:01/01/1985
FSC:8010
NIIN:00K001225
Kit Part:Y
MSDS Number: BCCLC

Responsible Party
DEFT CHEMICAL COATINGS
17451 VON KARMAN AVE
IRVINE, CA 92714-6205
US

Cage: EO418

Contractor
DEFT, INC.
IRVINE, CA 92614 US

Telephone: 949-474-0400

Cage: 33461

Ingredients

METHYL ETHYL KETONE (2-BUTANONE) (MEK) (SARA III)

CAS: 78-93-3

RTECS: EL6475000

Fraction By Weight: 17.0%

OSHA PEL 200 PPM/300 STEL

ACGIH TLV: 200 PPM/300STEL 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


2-METHOXYETHANOL (EGME) (SARA III)

CAS: 109-86-4

RTECS: KL5775000

Fraction By Weight: 5.0%

OSHA PEL S, 25 PPM

ACGIH TLV: S, 5 PPM; 9192


N-PROPYL ACETATE

CAS: 109-60-4

RTECS: AJ3675000

Fraction By Weight: 14.0%

OSHA PEL 200 PPM/250 STEL

ACGIH TLV: 200 PPM/250STEL;9192


ISOBUTYL ACETATE (SARA III)

CAS: 110-19-0

RTECS: AI4025000

Fraction By Weight: 6.0%

OSHA PEL 150 PPM

ACGIH TLV: 150 PPM; 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


N-BUTYL ALCOHOL (SARA III)

CAS: 71-36-3

RTECS: EO1400000

Fraction By Weight: 2.0%

OSHA PEL 100 PPM

ACGIH TLV: S, C 50 PPM; 9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

Effects of Overexposure:SKIN/EYES:IRRITATION;INH:IRRIT OF RESP
TRACT/ACUTE NERVOUS SYSTEM DEPRESSION;HEADACHE,DIZZINESS,ETC.

First Aid

First Aid:EYES:IMMED FLUSH W/LG VOLUME OF WATER FOR AT LEAST 15 MIN.GET
MED ATTN;SKIN:WASH AFFECTED AREA W/WATER.REMOVE CONTAMINATED
CLOTHING.GET MED ATTN IF IRRIT OCCURS;INH:REMOVE FROM EXPOSURE
BREATHING BY C PR, KEEP WARM & QUIET.GET MED ATTN.

Fire Fighting

Flash Point:20F(-6.6C)-TCC
Lower Limits:UNK
Extinguishing Media:CARBON DIOXIDE,FOAM OR DRY CHEM.(CLASS B FIRE
EXTINGUISHER)
Fire Fighting Procedures:SELF-CNTND BRTHG APP;USE H*2O SPRAY TO COOL
FIRE EXPSD CNTNR
Unusual Fire/Explosion Hazard:CLOSD CONTNRS MAY EXPLODE IN HEAT OF
FIRE;SPILL/RUNOFF MAYCAUSE POLLUTION,FIRE,&/OR EXPLOSION HAZARD

Accidental Release

Spill Release Procedures:ELIM IGN SOURCES.VENTIALATE AREA.USE PROTECTV
EQUIP.STORP LEAD W/O RISK.SM SPILL:CONTAIN/REMOVE W/INERT ABSROBENT
& NON-SPARKINGTOOLS.PLACE IN COVERED CONTNRS;SPILL:DIKE AREA & PUMP
LIQ TO SALVAGE TAN K. ABSORB REMAINING LIQ & SHOVEL UP INTO
CONTAINR.

Handling

Handling and Storage Precautions:STORE IN COOL,DRY WELL VENTILATED,LOW
FIRE RISK AREA.KEEP CLOSURE TIGHT & CNTNR UPRIGHT.STORE AWAY FM
IGN/HEAT SOURCES.PROTECT FM PHYSICAL DAMAGE.
Other Precautions:PREVENT PROLONGD/REPEATD BREATHING OF VAP OR SPRAY
MIST.CAN CAUSE ALLERGIC REACTION.FOLLOW SPECIAL PRECAUTIONS TO
APPLY ON HOT SURFACES.IF WATER IS USED FOR FIRE,FOG NOZZLES ARE
PREFERABLE.

Exposure Controls

Respiratory Protection:NIOSH APPROVD RESP FOR PAINT,LAQUER,ENAMEL
MISTS,ORGANIC VAPORS,ETC.
Ventilation:ADEQUATE USING EXHAUST FAN OR IAW 29CFR PART 1910.94
Protective Gloves:NEOPRENE/RUBBER
Eye Protection:SAFETY GLASSES W/SIDESHLD
Other Protective Equipment:CLEAN,LONG SLEEVE/LONG LEG PROTECTIVE
CLOTHING.
Supplemental Safety and Health
MSDS DATED: 4/12/83: THIS IS BASE, TWO PART KIT: SEE P/N IND B FOR
CTLST: ALSO CONTAINS: 9% LEAD CHROMATE, 9% TOLUENE, 12%
BUTYLCELLOSLVE, & LO.2% XYLENE, & 26% NON-AQUEOUS SOL HAZ UNK,
UNIDENTIFD. KE Y1: J1.

Chemical Properties

Boiling Pt:B.P. Text:175-340F
Vapor Density:>1.0
Spec Gravity:1.1465
Evaporation Rate & Reference:<1(SLWR THAN ETHR)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:RED PAINT EPOXY-ODOR OF KETONE
Percent Volatiles by Volume:73.8

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZING/CORROSIVE MATL, ACID & BASES
Stability Condition to Avoid:SOURCE OF IGN,HAT,SPARK,ETC.,& ELEVATED
TEMPERATURES.
Hazardous Decomposition Products:CO*2,CO.
Conditions to Avoid Polymerization:ELEVATED TEMPERATURES.

Disposal

Waste Disposal Methods:KEEP IN CLOSED CONTAINERS PENDING
DISPOSAL.DISPOSE ABSORBED LIQ/RESIDUE IN CLOSED CONTNRS BY SANITARY
LANDFILL;INCINERATE LIQ IN APPROVED FACILITY.DO NOT INCINERATE
CLSED CONTAINERS.HANDLE/DISPOSE IN FULL COMPLIANCE W/ALL
FED,STATE,& LOCALREGS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.