BCDCV - NYLON XT-301EXPERIMENTAL/E13030-127E
- MSDS: BCDCV
- Manufacturer: E I DUPONT DE NEMOURS AND COMPANY INC
- Product Name: NYLON XT-301EXPERIMENTAL/E13030-127E
- National Stock Number: 9390-00K001552
Product Identification
Product ID:NYLON XT-301EXPERIMENTAL/E13030-127E
MSDS Date:01/01/1985
FSC:9390
NIIN:00K001552
MSDS Number: BCDCV
Responsible Party
Emergency Phone: (302) 774-2421
Cage: DO229
Contractor
Telephone: 800-441-7515
Cage: DO229
Ingredients
POLYOLEFIN MODIFIED POLYAMIDE
Fraction By Weight: 100%
Hazards
Effects of Overexposure:NONE NOTED BY MFR. LOW TOXICITY & LOW HAZARD TO
HEALTH.
First Aid
First Aid:IF MOLTEN POLYMER CONTACTS SKIN,COOL RAPIDLY WITH COLD WATER
& OBTAIN MEDICAL ATTENTION FOR THERMAL BURN.
Fire Fighting
Flash Point:APPROX 750F
Extinguishing Media:CO*2, FOAM, DRY CHEM.
Fire Fighting Procedures:NONE
Unusual Fire/Explosion Hazard:NONE
Accidental Release
Spill Release Procedures:USE PROTECTIVE EQUIPMENT SUCH AS GLOVES/SAFETY
GLASSES.SWEEP UP TO PREVENT SLIPPINGK HAZARD ON POLYMER
GRANULES.PLACE IN CLOSED CONTAINERS FOR LATER DISPOSAL.
Handling
Handling and Storage Precautions:DRY STORAGE.KEEP CONTAINERK CLOSED TO
PREVENT CONTAMINATION BY MOISTURE ABSORPTION.
Other Precautions:WEAR GLOVES WHEN NYLON IS HOT;USE SAFETY GLASSES
DURING PROCESSING.
Exposure Controls
Respiratory Protection:NONE UNDER NORMAL PROCESSING
Ventilation:LOCAL EXHAUST AT MOLDING MACHINE
Protective Gloves:SEE OTHER PRECA
Eye Protection:SEE OTHER PRECAUTIONS
Other Protective Equipment:NONE
Supplemental Safety and Health
MFR SPECIFIED FLASH POINT 750F IS ESTIMATED BASED ON OTHER NYLONS USING
ASTM D-1929 METHOD;ITEM FORMERLY KNOWN AS E13030-127E (SUPER TUF)
Chemical Properties
HCC:N1
Spec Gravity:1.01
Evaporation Rate & Reference:UNKNOWN(NIL)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:OFF-WHITE GRANULES;NO ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS & OXIDIZING AGENTS.
Stability Condition to Avoid:AVOID HEATING ABOVE 625F
Hazardous Decomposition Products:AMMONIA & CARBON MONOXIDE.
Disposal
Waste Disposal Methods:MFR SPECIFIES INCINERATION OR LANDFILL IN
COMPLIANCE W/LOCAL STATE & FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.