BFCDX - PRO-SEAL 727 ACCELERATOR

  • MSDS: BFCDX
  • Manufacturer: ESSEC CHEMICAL CORP
  • Product Name: PRO-SEAL 727 ACCELERATOR
  • National Stock Number: 8030-00-515-2271
Product Identification

Product ID:PRO-SEAL 727 ACCELERATOR
MSDS Date:01/01/1985
FSC:8030
NIIN:00-515-2271
Kit Part:Y
MSDS Number: BFCDX

Responsible Party
ESSEC CHEMICAL CORPORATION

Emergency Phone: 213-537-7600

Cage: LO497

Contractor
ESSEX CHEMICAL CORP PRO-SEAL DIV
COMPTON, CA 90221-5713 US

Telephone: 310-537-7600

Cage: 83527

Ingredients

LEAD PEROXIDE

Fraction By Weight: 60%

ACGIH TLV: 0.2M9/M3

Hazards

Effects of Overexposure:IF INGESTED-NAUSEA, VOMITING, HEADACHE

First Aid

First Aid:CONSULT PHYSICIAN IMMEDIATELY

Fire Fighting

Flash Point:>230F,>110C
Extinguishing Media:DRY CHEMICAL, FOAM, CO2, WATER

Accidental Release

Spill Release Procedures:CLEAN UP WITH RAGS OR SWEEPING COMPOUND

Handling

Handling and Storage Precautions:AVOID CONTACT AND INGESTION STORE IN
CLOSED CONTAINER BELOW 80F.

Exposure Controls

Ventilation:RECOMMEND LOCAL EXHAUST
Protective Gloves:NEOPRENE
Eye Protection:SAFETY GOGGLES
Other Protective Equipment:COVERALLS, APRON
Supplemental Safety and Health
KEY1:J5.

Chemical Properties

HCC:V4
Spec Gravity:2.2
Appearance and Odor:BROWN PASTE, SLIGHT ODOR
Percent Volatiles by Volume:0

Stability

Stability Indicator/Materials to Avoid:YES

Disposal

Waste Disposal Methods:IN ACCORDING WITH FEDERAL, STATE AND LOCAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.