BFCDX - PRO-SEAL 727 ACCELERATOR
- MSDS: BFCDX
- Manufacturer: ESSEC CHEMICAL CORP
- Product Name: PRO-SEAL 727 ACCELERATOR
- National Stock Number: 8030-00-515-2271
Product Identification
Product ID:PRO-SEAL 727 ACCELERATOR
MSDS Date:01/01/1985
FSC:8030
NIIN:00-515-2271
Kit Part:Y
MSDS Number: BFCDX
Responsible Party
Emergency Phone: 213-537-7600
Cage: LO497
Contractor
Telephone: 310-537-7600
Cage: 83527
Ingredients
LEAD PEROXIDE
Fraction By Weight: 60%
ACGIH TLV: 0.2M9/M3
Hazards
Effects of Overexposure:IF INGESTED-NAUSEA, VOMITING, HEADACHE
First Aid
First Aid:CONSULT PHYSICIAN IMMEDIATELY
Fire Fighting
Flash Point:>230F,>110C
Extinguishing Media:DRY CHEMICAL, FOAM, CO2, WATER
Accidental Release
Spill Release Procedures:CLEAN UP WITH RAGS OR SWEEPING COMPOUND
Handling
Handling and Storage Precautions:AVOID CONTACT AND INGESTION STORE IN
CLOSED CONTAINER BELOW 80F.
Exposure Controls
Ventilation:RECOMMEND LOCAL EXHAUST
Protective Gloves:NEOPRENE
Eye Protection:SAFETY GOGGLES
Other Protective Equipment:COVERALLS, APRON
Supplemental Safety and Health
KEY1:J5.
Chemical Properties
HCC:V4
Spec Gravity:2.2
Appearance and Odor:BROWN PASTE, SLIGHT ODOR
Percent Volatiles by Volume:0
Stability
Stability Indicator/Materials to Avoid:YES
Disposal
Waste Disposal Methods:IN ACCORDING WITH FEDERAL, STATE AND LOCAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.