BFCXD - BROWN 30277;796-034;LACOQUER LUSTERLESS

  • MSDS: BFCXD
  • Manufacturer: ENMAR
  • Product Name: BROWN 30277;796-034;LACOQUER LUSTERLESS
  • National Stock Number: 8010-00-527-3196
Product Identification

Product ID:BROWN 30277;796-034;LACOQUER LUSTERLESS
MSDS Date:01/01/1987
FSC:8010
NIIN:00-527-3196
MSDS Number: BFCXD

Responsible Party
ENMAR
201 N BERRY ST
BREA, CA 92621-3904
US

Cage: OO111

Contractor
ENMAR
BREA, CA 92621-3904 US

Telephone: (316)-7333-1361

Cage: OO111

Ingredients

ISOPROPYL ALCOHOL (SARA III)

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: 6.08%

OSHA PEL 400 PPM/500 STEL

ACGIH TLV: 400 PPM/500STEL;9192


ISOBUTYL ALCOHOL (SARA III)

CAS: 78-83-1

RTECS: NP9625000

Fraction By Weight: 5.90%

OSHA PEL 100 PPM

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ISOBUTYL ACETATE (SARA III)

CAS: 110-19-0

RTECS: AI4025000

Fraction By Weight: 23.6%

OSHA PEL 150 PPM

ACGIH TLV: 150 PPM; 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


NAPHTHA (PETROLEUM SPIRITS OR BENZIN)

CAS: 8030-30-6

RTECS: SE7555000

Fraction By Weight: 23.3%

OSHA PEL 100 PPM

Hazards

Effects of Overexposure:INH:ANESTHETIC, IRRIT OF RESP TRACT OR ACUTE
CNS DEPRSSN W/HDACHE,DIZ,UNCON,COMA.SKIN & EYE:IRRIT.

First Aid

First Aid:IN CASE OF CONTACT, FLUSH SKIN & EYES W/PLENTY OF WATER WHILE
REMOVING CONTAMINATED CLOTHING. IF INHALED, REMOVE TO FRESH AIR.
CALL A PHYSCIAN IF SYMPTOMS PERSIST.

Fire Fighting

Flash Point:50F TCC
Lower Limits:0.9
Extinguishing Media:SM FIRES:CO*2,DRY CHEM. LG FIRES:POLYMER FOAM
PREFERRED.
Fire Fighting Procedures:USE SELF-CONTAINED BREATHING APPARATUS
Unusual Fire/Explosion Hazard:CLOSED CONTANERS EXPOSED TO HEAT MAY
EXPLODE DUE TO PRESSURE BUILD-UP.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION (FLAME, HOT
SURFACES, & ELECTRICAL,STATIC, OR FRICTIONAL SPARKS).AVOID BREATING
VAPORJS. VENTILATE AREA.REMOVE W/INERT ABSORBENT & NON-SPARKING
TOOLS.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 120F.STORE LG QTY
IN BLDG DESIGNED TO STORE NFPA CLASS ONE FLAM LIQ DO NOT TAKE
INTERNALLY. ADD LABEL WARNING.
Other Precautions:GROUND CONTANERS WHEN POURING. AVOID FREE FALL OF LIQ
IN EXCESS OF FEW IN. DO NOT FLAME CUT, BRAZE, OR WELD COATED
MATERIAL W/O APPROVED RESPIRATOR OR APROPRIATE VETILATION. DOT:FLAM
LIQUID

Exposure Controls

Respiratory Protection:RESTRICT VENT:CHEM-MECH FLTR.CLSD:AIR-LINE TYPE
Ventilation:GEN DILTN/LOCAL EXHST TO KEEP TLV/LEL BELOW LIMIT, REMV
FUME
Protective Gloves:YES
Eye Protection:YES FOR SPLASH
Other Protective Equipment:AVOID LONG EXPOSURE TO CONTAM CLOTHINGJ
Supplemental Safety and Health
THIS PRODUCT IS AN OBLITERATING LACQUER.VAPOR PRESSURE:3.12;VAPOR
DENSITY:HEAVIER THAN AIR. WT PER GALLON 9.0 LBS

Chemical Properties

HCC:F2
Boiling Pt:B.P. Text:175-290F
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:75.7

Stability

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:AVOID FIRES, HEAT &HOT SURFACES

Disposal

Waste Disposal Methods:DO NOT INCINERATE CLOSED CONTANER. DISPOSE IN
ACCORDANCE W/FED., STATE & LOCA REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.