BFCYR - 146 4114, KODAK RAPID FIXER, PART B

  • MSDS: BFCYR
  • Manufacturer: EASTMAN KODAK COMPANY
  • Product Name: 146 4114, KODAK RAPID FIXER, PART B
  • National Stock Number: 6750-00-528-0473
Product Identification

Product ID:146 4114, KODAK RAPID FIXER, PART B
MSDS Date:11/08/1995
FSC:6750
NIIN:00-528-0473
Kit Part:Y
MSDS Number: BFCYR

Responsible Party
EASTMAN KODAK COMPANY
343 STATE STREET
ROCHESTER, NY 14650
US

Emergency Phone: 716-722-5151

Info Phone: 800- 242-2424

Cage: 19139

Contractor
EASTMAN KODAK CO US CUSTOMER SERVICE/GOVERNMENT SALES
ROCHESTER, NY 14650-3129 US

Telephone: 800-828-6203

Cage: 5K871

Ingredients

WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 70-75%


ALUMINUM SULFATE

CAS: 10043-01-3

RTECS: BD1700000

Fraction By Weight: 15-20%

OSHA PEL 2 MG/M3

ACGIH TLV: 2 MG/M3; 9596

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


SULFURIC ACID (SARA 302/313) (CERCLA)

CAS: 7664-93-9

RTECS: WS5600000

Fraction By Weight: 10-15%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3/3 STEL; 9596

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:ORAL LD50 (RAT): 0.5-5.0 G/KG
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION-EXPECTED TO BE A LOW
INHALATION HAZARD FOR RECOMMENDED HANDLING. EYE-CAUSES IRRITATION.
SKIN-CAUSES IRRITATION. INGESTION-HARMFUL IF SWALLOWED. MAY CAUSE
BURNS OF THE GASTROINTESTINAL TRACT IF SWALLOWED.
Explanation of Carcinogenicity:IARC HAS DETERMINED THAT OCCUPATIONAL
EXPOSURE TO STRONG ACIDS MAY BE CARCINOGENIC TO HUMANS.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHALATION: IF SYMPTOMATIC, MOVE TO FRESH AIR. GET MEDICAL
ATTENTION IF SYMPTOMS PERSIST. EYES: IMMEDIATELY FLUSH WITH WATER
FOR 15 MINUTES. GET MEDICAL ATTENTION. SKIN: IMMEDIATELY REMOVE
CONTAMINATE D CLOTHING AND WASH WITH SOAP AND WATER.GET MEDICAL
ATTENTION. INGESTION: DO NOT INDUCE VOMITING. GIVE VICTIM A GLASS
OF WATER. SEKK MEDICAL ATTENTION. NEVER GIVE ANYTHING BY MOUTH IF
UNCONSCIOUS.

Fire Fighting

Flash Point:NONFLAMMABLE
Extinguishing Media:USE APPROPRIATE AGENT FOR ADJACENT FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING. FIRE OR EXCESSIVE HEAT MAY PRODUCE HAZARDOUS
DECOMPOSITION PRODUCTS.
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:MAY REQUIRE NEUTRALIZATION. FLUSH TO SEWER IF
ALLOWABLE WITH LARGE AMOUNTS OF WATER. OTHERWISE, ABSORB SPILL WITH
VERMICULITE OR OTHER INERT MATERIAL, THEN PLACE IN A CONTAINER FOR
CHEMICAL WASTE. CLE AN SURFACE TO REMOVE RESIDUAL CONTAMINATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CONTAINER TIGHTLY CLOSED. KEEP
AWAY FROM INCOMPATIBLES.
Other Precautions:DO NOT BREATHE MIST OR VAPOR. AVOID CONTACT WITH
EYES, SKIN AND CLOTHING. USE WITH ADEQUATE VENTILATION. WASH
THOROUGHLY AFTER HANDLING.

Exposure Controls

Respiratory Protection:NONE SHOULD BE NEEDED.
Ventilation:GOOD GENERAL VENTILATION, TYPICALLY 10 AIR CHANGES PER
HOUR, SHOULD BE USED. RATES SHOULD MATCH CONDITIONS.
Protective Gloves:WEAR IMPERVIOUS GLOVES.
Eye Protection:SAFETY GLASSES W/SIDE SHIELDS OR GOGGLES
Other Protective Equipment:EYE BATH, WASHING FACILITIES, SAFETY SHOWER.
WEAR PROTECTIVE CLOTHING APPROPIATE FOR THE RISK OF EXPOSURE.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
KEY1;C1.REFER TO PNIND-D(PT.A);PNIND-W(WORKING SOLUTION FOR
FILM);PNIND-X(WORKING SOLUTION FOR PAPER).

Chemical Properties

HCC:C1
Boiling Pt:>100.C, 212.F
Vapor Pres:18 MMHG
Vapor Density:0.6
Spec Gravity:1.30
pH:1.0
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS LIQUID, SLIGHT SULFUR DIOXIDE ODOR
Percent Volatiles by Volume:70-75%

Stability

Stability Indicator/Materials to Avoid:YES
BASES
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:SULFUR DIOXIDE

Disposal

Waste Disposal Methods:DISCHARGE, TREATMENT OR DISPOSAL MAY BE SUBJECT
TO NATIONAL, STATE OR LOCAL LAWS. MAY REQUIRE NEUTRALIZATION IF PH
< 2.0 OR PH > 12.5. FLUSH TO SEWER WITH LARGE AMOUNTS OF WATER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.