BFDLH - PM501M1 HARDENER

  • MSDS: BFDLH
  • Manufacturer: PALMER INTERNATIONAL
  • Product Name: PM501M1 HARDENER
  • National Stock Number: 5610-00-541-6719
Product Identification

Product ID:PM501M1 HARDENER
MSDS Date:01/01/1987
FSC:5610
NIIN:00-541-6719
MSDS Number: BFDLH

Responsible Party
PALMER INTERNATIONAL

Emergency Phone: 800-3414408

Cage: 00933

Contractor
PALMER INTERNATIONAL, INC.
WORCESTER, PA 19490 US

Telephone: 610-584-4241

Cage: 00933

Ingredients

XYLENES (O-,M-,P- ISOMERS) (SARA III)

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 18.0%

OSHA PEL 100 PPM/150 STEL

ACGIH TLV: 100 PPM/150STEL;9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ISOBUTYL ALCOHOL (SARA III)

CAS: 78-83-1

RTECS: NP9625000

Fraction By Weight: 4.0%

OSHA PEL 100 PPM

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

Effects of Overexposure:HEADACHE,DIZZINESS,NAUSEA.SKIN:IRRITATION &
DRYING.EYE:MAY CAUSE REDDENING & IRRITATION

First Aid

First Aid:REMOVE TO FRESH AIR.WASH WITH SOAP & WATER.FLUSH EYES WITH
WATER 15 MINUTES.CONSULT PHYSICIAN IF INGESTED.DO NOT INDUCE
VOMITING.CONTACT PHYSICIAN

Fire Fighting

Flash Point:83F PMCC
Lower Limits:1.0
Upper Limits:7.0
Extinguishing Media:CO2,DRY CHEMICAL.POLYMER FOAM FOR LARGE FIRES
Fire Fighting Procedures:USE SELF CONTAINED BREATHING APPARATUS

Accidental Release

Spill Release Procedures:ELIMINATE SOURCES OF IGNITION.PROVIDE ADEQUATE
VENTILATION.SOAK UP WITH ABSORBENT MATERIAL

Exposure Controls

Ventilation:LOCAL EXHAUST SUFFICIENT TO MAINTAIN TLV IS REQUIRED
Protective Gloves:RUBBER
Eye Protection:MONOGOGGLES
Other Protective Equipment:EYE WASH & SAFETY SHOWER
Supplemental Safety and Health

Chemical Properties

HCC:F4
Boiling Pt:B.P. Text:226F
Vapor Pres:8.9
Vapor Density:3.4
Spec Gravity:.95
Evaporation Rate & Reference:.7
Solubility in Water:NEGLIGIBLE
Appearance and Odor:AMBER LIQUID WITH AMINE LIKE ODOR
Percent Volatiles by Volume:25.0

Stability

STRONG ACIDS

Disposal

Waste Disposal Methods:INCINERATE IN A FURNACE OR LANDFILL IN
ACCORDANCE WITH ALL FEDERAL,STATE & LOCAL REQUIREMENTS

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.