BHCKY - COATING, POLYURETHANE AIRCRAFT BLACK 37038

  • MSDS: BHCKY
  • Manufacturer: PRATT AND LAMBERT INC
  • Product Name: COATING, POLYURETHANE AIRCRAFT BLACK 37038
  • National Stock Number: 8010-01-144-9879
Product Identification

Product ID:COATING, POLYURETHANE AIRCRAFT BLACK 37038
MSDS Date:10/14/1988
FSC:8010
NIIN:01-144-9879
Kit Part:Y
MSDS Number: BHCKY

Responsible Party
PRATT & LAMBERT, INC.
16116 E 13TH ST
WICHITA, KS 67201
US

Preparer: W.A. ELLISON

Cage: FO127

Contractor
PRATT AND LAMBERT INC
22 CLEVELAND, OH 44101-1027 US

Telephone: 216-566-2902

Cage: 61196

Ingredients

PROPYLENE GLYCOL METHYL ETHER ACETATE (VP MM HG @ 20 DEG C

CAS: 108-65-6

RTECS: AI8925000

OSHA PEL NONE ESTABLISHED

ACGIH TLV: NONE ESTABLISHED


TOLUENE (SARA III)

CAS: 108-88-3

RTECS: XS5250000

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


CARBON BLACK

CAS: 1333-86-4

RTECS: FF5800000

OSHA PEL 3.5 MG/M3

ACGIH TLV: 3.5 MG/M3; 9192


METHYL ETHYL KETONE (2-BUTANONE) (MEK) (SARA III)

CAS: 78-93-3

RTECS: EL6475000

OSHA PEL 200 PPM/300 STEL

ACGIH TLV: 200 PPM/300STEL 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


SILICA, CRYSTALLINE - CRISTOBALITE

CAS: 14464-46-1

RTECS: VV7325000

OSHA PEL SEE TABLE Z3

ACGIH TLV: 0.05 MG/M3 RDUST9293


SILICA, CRYSTALLINE - QUARTZ

CAS: 14808-60-7

RTECS: VV7330000

OSHA PEL SEE TABLE Z3

ACGIH TLV: 0.1 MG/M3 RDUST;9293


SILICA, AMORPHOUS, DIATOMACEOUS EARTH, CONTAINING LESS THAN

CAS: 61790-53-2

RTECS: HL8600000

OSHA PEL 20 MPPCF

ACGIH TLV: 10 MG/M3 TDUST; 9293


VOL ORGANIC CMPD 4.3 LB/GL LESS WATER & NPRS* 516 G/L LESS

RTECS: 9999999VO

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Health Hazards Acute and Chronic:SWALLOWING-GASTROINTESTINAL
IRRITATION, ASPIRATION OF MATERIAL INTO LUNG MAY CAUSE CHEMICAL
PNEUMONITIS. EYE AND SKIN-IRRITATION. HIGH CONCENTRATIONS MAY CAUSE
ACUTE CENTRAL NERVOUS SYSTEM DEPRESSION CHARACTERIZED BY HEADACHE,
DIZZINESS, NAUSEA AND CONFUSION.
Explanation of Carcinogenicity:TOLUENE HAS BEEN FOUND TO CAUSE KIDNEY,
LUNG AND SPLEEN DAMAGE IN LABORATORY ANIMALS.
Effects of Overexposure:REPEATED EXPOSURE TO CRYSTALLINE SILICA MAY
CAUSE LUNG DISEASE. (PNEUMOCONIOSIS) OVEREXPOSURE TO TOLUENE MAY
CAUSE LIVER DAMAGE. OVEREXPOSURE TO SOLVENTS WITH PERMANENT
BRAIN/NERVOUS SYSTEM DAMAGE.
Medical Cond Aggravated by Exposure:PREEXISTING RESPIRATORY CONDITIONS
MAY BE AGGRAVATED BY EXPOSURE TO CRYSTALLINE SILICA.

First Aid

First Aid:SWALLOWING-DO NOT INDUCE VOMITING. GET MED ATTN.
INHALATION-REMOVE TO FRESH AIR AND GET MED ATTN. EYE-FLUSH WITH
WATER FOR 15 MIN. GET MED ATTN.SKIN:REMOVE CONTAMINATED CLOTHING,
WASH AFFECTED AREA IF IRRITATION PERSISTS.GET MED ATTN. NOTETO
PHYSICIAN ANY TREATMENT THAT MIGHT BE REQUIRED FOR OVEREXPOSURE
SHOULD BE DIRECTED AT THE CONTROL OF SYMPTOMS AND THE CLINICAL
CONDITIONS.

Fire Fighting

Flash Point:24F/-4.44C
Extinguishing Media:USE CLASS B FIRE EXTINGUISHERS. POLYMER FOAM IS
PREFERRED FOR LARGE FIRES.
Fire Fighting Procedures:WEAR SELF CONTAINED BREATHING APPARATUS. USE
WATER TO COOL EXPOSED CONTAINERS TO PREVENT POSSIBLE AUTO
IGNITION/EXPLOSION. USE FOG NOZZLES IF WATER IS USED.
Unusual Fire/Explosion Hazard:OVEREXPOSURE TO DECOMPOSITION MAY CAUSE
HEALTH HAZARD. SYMPTOMS MAY NOT BE IMMEDIATELY APPARENT. OBTAIN
MEDICAL ATTENTION. WARNING: FLAMMABLE.

Accidental Release

Spill Release Procedures:ELIMINATE ALL IGNITION SOURCES. DIKE AND
CONTAIN SPILL WITH INERT MATERIAL. RECOVERY OR DISPOSAL IN A
COVERED METAL CONTAINER. USE NON SPARKING TOOLS.PREVENT
CONTAMINATION OF SEWERS,STREAMS,GROUNDWATE R.
Neutralizing Agent:NONE LISTED.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 95F. STORE LARGE
QUANTITIES IN COMPLIANCE WITH OSHA 29CFR1910.106.
Other Precautions:DO NOT TAKE INTERNALLY. CLOSE CONTAINER AFTER EACH
USE. DO NOT BREATH SANDING DUST. DO NOT RE-USE CONTAINER. DO NOT
WELD/BRAZE OR CUT ON EMPTY CONTAINER. NEVER USE PRESSURE TO EMPTY.
CONT GROUNDED AND BONDED TO THE RECEIVING CONTAINER.

Exposure Controls

Respiratory Protection:RESPIRATORS RECOMMENDED WITH THIS PRODUCT DURING
AND AFTER THE ADDITION OF CATALYST: PROPERLY FITTED POSITIVE
PRESSURE (TC 19C NIOSH/MSHA) WHILE EXPOSED. IF NOT AVAILABLE USE
VAPOR PARTICULATE, THAT I S EFFECTIVE FOR ISOCYANATE VAPORS AND
Ventilation:GENEAL DILUTION AND LOCAL EXHAUST VENT IN SUFFICIENT VOLUME
& PATTERN TO MAINTAIN CONCENTRATIONS OF HAZARDOUS SUBSTANCES
Protective Gloves:SOLVENT IMPERMEABLE GLOVES ARE REQUIRED.
Eye Protection:WEAR SAFETY SPECTACLES.
Other Protective Equipment:NOT LIKELY TO BE NEEDED.
Work Hygienic Practices:NONE LISTED.
Supplemental Safety and Health
RESPIRATORY PROTECTION: MISTS. WEAR RESPIRATOR FOR THE WHOLE TIME WHILE
MIX SPRAYING AND UNTIL VAPORS AND MISTS ARE GONE. THIS URETHANE
BASE IS ONE PART OF A TWO COMPONENT MIXTURE. INTENDED TO BE MIXE D
WITH AN ACTIVATOR. THE CONTENTS OF THIS PKG MUST BE BLENDED WITH
OTHER COMPONENTS BEFORE THE PRODUCT CAN BE USED.

Chemical Properties

Boiling Pt:B.P. Text:175F/281F
Vapor Density:>AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:59

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS OR ALKALINE MATERIALS.
Stability Condition to Avoid:AVOID EXCESSIVE HEAT AND SOURCES OF
IGNITION.
Hazardous Decomposition Products:BURNING/WELDING/CUTTING WILL PRODUCE
SMOKE, CARBON MONOXIDE AND CARBON DIOXIDE.
Conditions to Avoid Polymerization:KEEP AWAY FROM HEAT,SPARKS AND
FLAME.

Disposal

Waste Disposal Methods:DISPOSE IAW FED/ST/LOCAL LAWS. INCINERATE ONLY
IN EPA FACILITY. DISPOSE IN A HAZARDOUS WASTE LANDFILL. RCRA
CLASSIFICATION WOULD BE D001. ENVIRONMENTAL HAZARDS NONE KNOWN.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.