BJCZN - A24 A 11 MEDIUM GRAY ACRYLIC LATEX FLOOR EN
- MSDS: BJCZN
- Manufacturer: SHERWIN WILLIAMS COMPANY
- Product Name: A24 A 11 MEDIUM GRAY ACRYLIC LATEX FLOOR EN
- National Stock Number: 8010-00F012458
Product Identification
Product ID:A24 A 11 MEDIUM GRAY ACRYLIC LATEX FLOOR EN
MSDS Date:04/04/1988
FSC:8010
NIIN:00F012458
MSDS Number: BJCZN
Responsible Party
CLEVELAND, OH 44115
Emergency Phone: (216) 566-2917
Info Phone: (216) 566-2902
Cage: 54636
Contractor
Telephone: 800-251-2486/216-566-2242
Cage: 54636
Ingredients
2-(2-BUTOXYETHYOXY)-ETHANOL, DIETHYLENE GLYCOL MONOBUTYL
CAS: 112-34-5
RTECS: KJ9100000
Fraction By Weight: <5%
ETHYLENE GLYCOL (SARA III)
CAS: 107-21-1
RTECS: KW2975000
Fraction By Weight: <5%
OSHA PEL C 50 PPM
ACGIH TLV: C 50 PPM,VAPOR; 9192
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
SILICA, CRYSTALLINE - QUARTZ
CAS: 14808-60-7
RTECS: VV7330000
Fraction By Weight: 0-5%
OSHA PEL SEE TABLE Z3
ACGIH TLV: 0.1 MG/M3 RDUST;9293
TITANIUM DIOXIDE
CAS: 13463-67-7
RTECS: XR2275000
Fraction By Weight: 0-20%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST; 9293
3)
CAS: 1308-38-9
RTECS: GB6475000
Fraction By Weight: <5%
OSHA PEL 1 MG/CUM
ACGIH TLV: 0.5 MG/CUM
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: IRRITATION OF THE UPPER
RESPIRATORY SYSTEM, HEADACHE, NAUSEA, & DIZZINESS. SKIN:
IRRITATION, REDNESS, ITCHING, & BURNING SENSATION. EYES:
IRRITATION.
Explanation of Carcinogenicity:CRYSTALLINE SILICA MAY POSSIBLY CAUSE
CANCER.
Effects of Overexposure:INHALATION: IRRITATION OF THE UPPER RESPIRATORY
SYSTEM, HEADACHE, NAUSEA, DIZZINESS, CRYSTALLINE SILICA MAY CAUSE
LUNG DAMAGE (SILICOSIS) & POSSIBLY CANCER, & ADVERSE EFFECTS TO THE
REPRODUCTIVE SYSTE . SKIN: IRRITATION, REDNESS, ITCHING, & BURNING
SENSATION. EYES: IRRITATION.
First Aid
First Aid:INHALATION: REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP
WARM & QUIET. SKIN: WASH AFFECTED AREA THOROUGHLY W/SOAP & WATER.
REMOVE CONTAMINATED CLOTHING & LAUNDER BEFORE RE-USE. EYES: FLUSH
W/WATER FO R 15 MINUTES. GET MEDICAL ATTENTION.
Fire Fighting
Flash Point Method:PMCC
Flash Point:>199F
Extinguishing Media:CO2, DRY CHEMICAL, ALCOHOL FOAM
Fire Fighting Procedures:WEAR SCBA & FULL PROTECTIVE EQUIPMENT. WATER
SPRAY MAY BE INEFFECTIVE. FOG NOZZLES ARE PREFERABLE. USE WATER TO
COOL CLOSED CONTAINERS.
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY EXPLODE DUE TO THE
BUILD-UP PRESSURE WHEN EXPOSED TO EXTREME HEAT.
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE &
REMOVE WITH INERT ABSORBENT.
Handling
Handling and Storage Precautions:KEEP CONTAINER CLOSED WHEN NOT IN USE.
DON'T TAKE INTERNALLY. KEEP OUT OF THE REACH OF CHILDRE USE ONLY
WITH ADEQUATE VENTILATION.
Other Precautions:AVOID BREATHING VAPOR & SPRAY MIST. AVOID CONTACT
W/SKIN & EYES. WASH HANDS AFTER USING. PROTECT AGAINST DUST WHICH
MAY BE GERATED BY SANDING OR ABRADING THE DRIED FILM.
Exposure Controls
Respiratory Protection:WEAR RESPIRATORY DEVICE APPROVED BY NIOSH/MSHA
IF >TLV.
Ventilation:PROVIDE LOCAL EXHAUST VENTILATION TO KEEP
Eye Protection:SAFETY SPECTACLES
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health
ETHYLENE GLYCOL IS CONSIDERED AN ANIMAL TERATOGEN. IF HAS BEEN SHOWN TO
CAUSE BIRTH DEFECTS IN RATS & MICE AT HIGH DOSES WHEN GIVEN IN
DRINKING WATER/GAVAGE. NO EVIDENCE OF BIRTH EFFECTS IN HUMANS. RA
TS EXPOSED TO TITANIUM DIOXIDE DUST DEVELOPED LUNG CANCER, HOWEVER,
SUCH EXPOSURE LEVEL IS NOT ATTAINABLE IN WORKPLACE.
Chemical Properties
Boiling Pt:B.P. Text:212-448F
Vapor Density:>AIR
pH:9.0
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:LIGHT GRAY LATEX GLOOS ENAMEL PAINT
Percent Volatiles by Volume:62-70%
Stability
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:HEAT, SOURCES OF IGNITION
Hazardous Decomposition Products:CO2, CO, OXIDES OF METALS
Disposal
Waste Disposal Methods:WASTE MUST BE TESTED FOR EXTRACTABILITY TO
DETERMINE THE APPLICABLE EPA HAZARDOUS WASTE NUMBERS. INCINERATE IN
APPROVED FACILITY. DON'T INCINERATE CLOSED CONTAINER. DISPOSE OF IN
ACCORDANCE WITH FEDER AL, STATE & LOCAL REGULATIONS
REGARDINGPOLLUTION
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.