BJDKC - 4817 N

Product Identification

Product ID:4817 N
MSDS Date:07/15/1988
FSC:8030
NIIN:00-919-9204
MSDS Number: BJDKC

Responsible Party
E.I. DUPONT DE NEMOURS & CO. INC. (EMD)
BARLEY MILL PLAZA
WILMINGTON, DE 19898
US

Emergency Phone: 800-441-3637, CANADA 613-348-3616

Info Phone: 800-441-7515, CHEMTREC 800-424-9300

Cage: 19898

Contractor
E.I. DUPONT DE NEMOURS & CO., INC.
1635 NIAGARA FALLS, NY 14302 US

Telephone: 302-892-1227 ?

Cage: 19898

Ingredients

1-METHOXY-2-PROPANOL ACETATE

CAS: 108-65-6

RTECS: AI8925000

Fraction By Weight: 10-50%


N-BUTYL ACETATE (SARA III)

CAS: 123-86-4

RTECS: AF7350000

Fraction By Weight: 10-50%

OSHA PEL 150 PPM/200 STEL

ACGIH TLV: 150 PPM/200STEL;9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


DIBUTYL PHTHALATE (SARA III)

CAS: 84-74-2

RTECS: TI0875000

Fraction By Weight: 0-3%

OSHA PEL 5 MG/M3

ACGIH TLV: 5 MG/M3; 9192

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


SILVER (SARA III)

CAS: 7440-22-4

RTECS: VW3500000

Fraction By Weight: 10-50%

OSHA PEL 0.01 MG/M3

ACGIH TLV: 0.1 MG/M3; 9192

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


ACRYLIC RESIN

Fraction By Weight: 10-50%


PROPRIETARY INGREDIENT(S)

Fraction By Weight: 0-3%

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:IRRITATION OF UPPER RESPIRATORY
PASSAGES; ABNORMAL LIVER FUNCTION AS DETECTED BYLABORATORY TESTS;
ABNORMAL KIDNEY FUNCTION AS DETECTED BY LABORATORY TESTS.
NON-SPECIFIC DISCOMFORT, E.G., NAUSEA, HEADA CHES WEAKNESS. SKIN
PERMEATION CAN OCCURIN AMT CAPABLE OF PRODUCING SYSTEMIC TOXICITY.
ABSORB CONTRIB TO INTERN TOXICITY
Explanation of Carcinogenicity:NO INGREDIENTS OF THIS PRODUCT ARE
DESIGNATED BY IARC, NTP, OSHA, ACGIH OR DUPONT AS POTENTIAL
CARCINOGENS.
Effects of Overexposure:SKIN IRRITATION WITH DISCOMFORT OR RASH; EYE
IRRITATION WITH DISCOMFORT, TEARINGBLURRING OF VISION. NONSPECIFIC
DISCOMFORT, E.G., NAUSEA, HEADACHE OR WEAKNESS. SKIN PERMEATION CAN
OCCUR IN AMOUNTS CAP ABLE OF PRODUCING EFFECTS OF SYSTEMIC
TOXICITY. ABSORPTION MAY CONTRIBUTE SIGNIFICANTLY TO INTERNAL
TOXICITY OF INGRED
Medical Cond Aggravated by Exposure:NK (NOTE TO PHYSICIAN: TO PREPARE
ACTIVATED CHAR-COAL SLURRY, SUSPEND 50G ACTIVATED CHARCOAL IN 400ML
WATER IN PLASTIC BOTTLE & SHAKE WELL. ADMINIS- TER 5 MG/KG, OR 350
ML FOR AN AVERAGE ADULT.)

First Aid

First Aid:SKIN: IMMED WASH WITH SOAP & PLENTY OF WATER. EYE: IMMED
FLUSH WITH PLENTY OF WATER FOR AT LEAST 15 MIN. CALL PHYSICIAN.
INHALE: REMOVE TO FRESH AIR IMMED. IFNO BREATH, GIVE CPR, IF BREATH
DIFF, GIVE OXYGEN, CALL PHYSICIAN. INGESTION: DO NOT INDUCE
VOMITING. IMMED GIVE 2 GLASSES OF WATER OR ACTIVATE CHARCOAL
SLURRY. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONCIOUS PERSON. CALL
PHYSICIAN.

Fire Fighting

Flash Point Method:TCC
Flash Point:72 F/ 22 C
Extinguishing Media:WATER SPRAY, DRY CHEMICAL OR CARBON DIOXIDE.
Fire Fighting Procedures:WEAR FULL PROTECT CLOTHES/FULL FACEPIECE,
POSITIVE PRESS, SCBA; DECONTAM CONTAM CLOTHES & EQUIP W/SOAP &
WATER. DISPOSE OF RESIDUES PER FED, STATE, LOCAL REGS.
Unusual Fire/Explosion Hazard:KEEP AWAY FROM IGNITE SOURCES. VAPORS
HEAVIER THAN AIR MAY TRAVEL ALONG GROUND TO SOURCE OF IGNITE &
FLASHBACK. USE APPROPRIATE NEC CLASS. USE NON-SPARK TOOLS.

Accidental Release

Spill Release Procedures:SM:ABSORB ON RAGS, SAND OR OTHER ABSORB
MATERIAL. LRG: CLEAR AREA OF NON ESSENTIAL PERSONS. IF FLAMMLIQ
PRESENT TURN OFF ELEC DEVICES/OTHER SOURCES OFIGNITE.WEAR PROTECT
EQUIP. USE SUPPIED AIR RSPTR. CONTAIN SPILL, DON'T LET SPREAD OR
FLUSH IN SEWER.

Handling

Handling and Storage Precautions:STORE BELOW 90F TO ENSURE VISCOSITY
STABILITY. DO NOT STORE IN AREAS WHERE VAPOR MAY CONTACT SOURCESOF
HEAT, SPARKS OR OPEN FLAMES.
Other Precautions:ADDITIONAL ENGINEERING CONTROLS, WORK PRACTICES &
TRAINING MAY BE REQUIRED DEPENDING ON EXPOSURE LEVELS. THESE ARE
DISCUSED IN OSHA RESPIRATORY PROTECION STAND-ARD (29 CDR 1910.134)
& OSHA HAZARD COMM UNICATION STANDARD (29 CFR 1910.1200).

Exposure Controls

Respiratory Protection:RESPIRATORY PROTECTION WILL BE NEEDED IF
EXPOSURES CAN NOT BE KEPT BELOW APPLIC-ABLE LIMITS BY OTHER MEANS.
CONSULT ANSI STANDARD Z88.2 FOR DECISION LOGIC TO SELECT
APPROPRIATE NIOSH/MESA APPROVED RES PIRATORS. INCLUDES AIR MONITOR,
TRAINING
Ventilation:LOCAL VENT SHOULD BE USED TO KEEP EXPOSURES BELOW
APPLICABLELIMITS. TOTALLY ENCLOSED HANDLING SYSTEMS ARE ALSO
PREFERRED
Protective Gloves:BUTYL RUBBER RECOMMENDED.
Eye Protection:CHEMICAL SPLASH GOGGLES ARE RECOMMENDED.
Other Protective Equipment:PROTECTIVE OUTER CLOTHES SHOULD BE USED
WHERE POSSIBILITY OFBODY CONTACT. CONTAM WORK CLOTHES SHOULDN'T
LEAVE WORK AREA.
Work Hygienic Practices:AFTER HANDLING PRODUCT, WASH HANDS THOROUGHLY
BEFORE LEAVINGWORK AREA. DON'T SMOKE, CONSUME OR STORE FOOD/DRINKS
IN AREA
Supplemental Safety and Health
PRODUCT IS A PHYSICAL MIXTURE. HEALTH EFFECTS INFORMATION ABOUT PRODUCT
IS BASEDON INDIVIDUAL INGREDIENTS. DATA IN THIS MSDS RELATES ONLY
TO SPECIFIC PRODUCT DESIGNATED HEREIN & DOES NOT RELATE TO ITS USE
IN COMBINATION WITH ANY OTHER MATERIAL OR IN ANY PROCESS.

Chemical Properties

HCC:F2
Solubility in Water:SLIGHT
Appearance and Odor:GREY LIQUID WITH A MILD FRUITY ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
NK
Stability Condition to Avoid:AVOID CONTACT WITH OXIDIZING AGENTS;
ACIDS; POTASSIUM TERT- BUTOXIDE.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
WATER; NITROGEN OXIDES.
Conditions to Avoid Polymerization:THE PRODUCT DOES NOT NORMALLY
POLYMERIZE SIGNIFICANTLY.

Disposal

Waste Disposal Methods:COMPONENTS OF PRODUCT MAY BE CONSIDERED
HAZARDOUS; WASTE PRODUCT MAY BE REFINED TO RECOVER PRECIOUS METAL
CONTENTS. CONTAMINATED CLOTHES & CLEANING MATERIALS, ETC. SHOULD BE
CONSIDERED HAZARDOUS UNTIL PROPERLY DISPOSED OF.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.