BLBKJ - PRO-SEAL 152 PRIMER
- MSDS: BLBKJ
- Manufacturer: PRODUCTS RESEARCH AND CHEMICAL CORP
- Product Name: PRO-SEAL 152 PRIMER
- National Stock Number: 8040-00N015891
Product Identification
Product ID:PRO-SEAL 152 PRIMER
MSDS Date:07/19/1988
FSC:8040
NIIN:00N015891
MSDS Number: BLBKJ
Responsible Party
GLENDALE, CA 91209
US
Emergency Phone: 818-240-2060
Info Phone: 818-240-2060
Preparer: KA
Cage: DO563
Contractor
Telephone: 818-240-2060
Cage: DO563
Ingredients
METHYL ETHYL KETONE (2-BUTANONE) (MEK) (SARA III)
CAS: 78-93-3
RTECS: EL6475000
Fraction By Weight: 20%
OSHA PEL 200 PPM/300 STEL
ACGIH TLV: 200 PPM/300STEL 9192
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ETHYL ACETATE (SARA III)
CAS: 141-78-6
RTECS: AH5425000
Fraction By Weight: 20%
OSHA PEL 400 PPM
ACGIH TLV: 400 PPM; 9192
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ISOPROPYL ALCOHOL (SARA III)
CAS: 67-63-0
RTECS: NT8050000
Fraction By Weight: 10%
OSHA PEL 400 PPM/500 STEL
ACGIH TLV: 400 PPM/500STEL;9192
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE:SEVERE IRRITATION.
SKIN:IRRITATION. INHAL:IRRITATION OF RESPIRATORY TRACT.
INGEST:TOXIC BY INGESTION.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYE:FLUSH W/LUKE WARM WATER FOR AT LEAST 15 MINUTES. CALL MD.
SKIN:WASH W/SOAP & WATER. IF SYMPTOMS PERSIST, CALL MD.
INHAL:REMOVE TO FRESH AIR. IF SYMPTOMS PRESENT, CALL MD.
INGEST:CALL MD.
Fire Fighting
Flash Point Method:TCC
Flash Point:24.0F,-4.4C
Lower Limits:1.8%
Upper Limits:11.5%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:HIGH TEMPERATURES MAY CAUSE PRESSURE
BUILDUP IN CLOSED CONTAINERS.
Accidental Release
Spill Release Procedures:REMOVE ALL IGNITION SOURCES. COVER
W/ABSORBENT. SCOOP INTO CONTAINERS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:PRODUCT CONTAINS TOXIC CHEMICAL/CHEMICALS SUBJECT TO
REPORTING REQUIREMENTS OF SECTION 313 OF TITLE III OF SUPERFUND
AMENDMENTS & REAUTHORIZATION ACT OF 1986 & 40 CFR PART 372.
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN .
Ventilation:GENERAL VENTILATION TO MAINTAIN VAPORS BELOW TLV. WHEN
SPRAYING, APPLYING IN CONFINED AREAS, OR IN OTHER (SUPP DATA)
Protective Gloves:SOLVENT RESISTANT GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES, (SUPP DATA)
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
VENT:CIRCUMSTANCES LIKELY TO PRODUCE AIRBORNE LEVELS OF SOLVENT IN
EXCESS OF TLV, USE NIOSH/MSHA APPROVED ORGANIC VAPOR CARTRIDGE
RESPIRATOR OR AIR-SUPPLIED RESPIRATOR. EYE PROT:MAY ADD FULL LENGTH
FA CESHIELD TO GOGGLES .
Chemical Properties
HCC:F3
Boiling Pt:B.P. Text:170F,77C
Vapor Pres:100
Vapor Density:2.81
Spec Gravity:0.82
Evaporation Rate & Reference:4
Solubility in Water:SLIGHT
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CO*X
Disposal
Waste Disposal Methods:EPA WASTE NO D-001. DISPOSE OF SPILLAGE IN
COMPLIANCE W/FEDERAL AND STATE REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.