BLBPH - CP-230 CHIL-FIX
- MSDS: BLBPH
- Manufacturer: CHILDERS PRODUCTS CO INC
- Product Name: CP-230 CHIL-FIX
- National Stock Number: 8040-00N016334
Product Identification
Product ID:CP-230 CHIL-FIX
MSDS Date:01/01/1990
FSC:8040
NIIN:00N016334
MSDS Number: BLBPH
Responsible Party
LEVITTOWN, PA 19057
US
Emergency Phone: 800-424-9300 (CHEMTREC)
Info Phone: 215-943-7600
Preparer: ROBERT ANDREWS
Cage: 3K675
Contractor
Cage: 3K675
Ingredients
HEXANE (N-HEXANE)
CAS: 110-54-3
RTECS: MN9275000
Fraction By Weight: 20-25%
OSHA PEL 500 PPM
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
TOLUENE (SARA III)
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 5-8%
OSHA PEL 200 PPM/150 STEL
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE) (SARA III)
CAS: 71-55-6
RTECS: KJ2975000
Fraction By Weight: 0-25%
OSHA PEL 350 PPM/450 STEL
ACGIH TLV: 350 PPM/450STEL;9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
METHYLENE CHLORIDE (SARA III)
CAS: 75-09-2
RTECS: PA8050000
Fraction By Weight: 0-20%
OSHA PEL 500 PPM/C,1000; Z2
ACGIH TLV: 50 PPM, A2; 9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
HYDROCARBON PROPELLANT
CAS: 68476-86-8
Fraction By Weight: 29-33%
EFFECT IN HUMANS. ADRENOMIMETICS (E.G., EPINEPHRINE)MAY BE
RTECS: 9999999ZZ
USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED TO
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: VAP MAY CAUSE HDCH &/DIZZ. LIQ
MAY CAUSE EYE INJURY. CHRONIC: VARIOUS STUDIES HAVE SHOWN A POSS
ASSOC W/EXPOS TO THE SOLV IN THIS PROD & THE FOLLOWING: RESP TRACT
IRRIT/LIVER DAM IN HUMANS/KIDN EY DAM IN HUMANS/NAUS/VOMIT. EYE:
MAY BE AN EYE IRRIT. MAY CAUSE TRANSIENT IRRIT W/CORNEAL
INJURY.(SEE EFTS OF OVEREXP).
Explanation of Carcinogenicity:DICHLOROMETHANE:GROUP 2B(IARC).
Effects of Overexposure:SKIN: MAY CAUSE SKIN IRRIT UPON PRLNG/RPTD
CONT. INHAL: HIGH VAP CONC(GREATER THAN APPROX 1000 PPM) ARE IRRIT
EYES/RESP TRACT & MAY CAUSE HDCH/DIZZ, ARE ANESTH, & MAY HAVE OTHER
CNS EFTS. INGEST: PROD HAS A LOW ORDER OF ACUTE ORL TOXICITY,BUT
MIN AMT ASPIR INTO LUNGS DURING INJEST MAY CAUSE SEVERE PULM
INJURY/DEATH.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYE: FLUSH THOROUGHLY W/H*2O FOR AT LST 15 MIN. CALL MD
IMMED. SKIN: WASH THOROUGHLY W/SOAP/H*2O. INHAL: IF BRTHG
DFCLT/DIZZ/LIM OCCUR WHEN WORK IN AREAS W/HIGH VAP CONC, VICTIM
SHOULD SEEK AIR FREE O F VAP. IF VICTIM CONTINUED BRTH DFCLT,
ADMINISTER O*2 UNTIL MED ASSIST CAN BE RENDERED. CALL MD IMMED. IF
BRTHG STOPS, BEGIN ARTF RESP & SEEK MD IMMED. INGEST: DO NOT INDUCE
VOMIT. SEEK MED ATTN.
Fire Fighting
Flash Point:<0
Lower Limits:1.0%
Upper Limits:8.0%
Extinguishing Media:FOAM, CO*2 DIOXIDE, OR DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT . AVOID SPREADING BURNING LIQUID WITH
WATER USED FOR COOLING PURPOSES.
Unusual Fire/Explosion Hazard:KEEP WORK AREAS FREE OF HOT METAL AND
OTHER SOURCES OF IGNITION. THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL AND PHOSGENE .
Accidental Release
Spill Release Procedures:KEEP SOURCES OF IGNITION ISOLATED FROM THE
SPILL. AVOID SKIN CONTACT AND BREATHING OF VAPORS. VENTILATE AREA.
SCRAPE MATERIAL INTO CLOSED CONTAINERS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP TIGHTLY CLOSED IN
COOL/DRY/VENTILATED AREA. PROTECT FROM STATIC DISCHARGE. NO SMOKING
IN AREA OF USE. DO NOT USE IN GEN VICIN OF (SEE OTHER PROC)
Other Precautions:HNDLG/STOR PREC: ARC WELD, OPEN FLAMES/HOT SURF. HEAT
& UV RADIA MAY CAUSE FORMATION OF HCL AND/OR PHOSGENE . IF BULK OR
LG GAS CYLINDERS: MAY DISPLACE OXYGEN IN ENCLOSED/CONFINED SPACES.
GAS/VA P MAY ACCUMULATE IN LOW AREAS .
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:GEN MECH VENT MAY BE SUFFICIENT TO KEEP PROD VAP CONC W/IN
TIME-WEIGHTED TLV RANGES. IF GEN VENT PROVES (SEE SUPP DATA).
Protective Gloves:IMPERMEABLE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:AVAILABILITY OF EYE WASHES/SAFETY SHOWERS IN
THE WORK AREA IS RECOMMENDED. THE USE OF IMPERMEABLE APRON IS
RECOMMEMDED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
VENT:INADEQ TO MAINTN SAFE VAP CONC,SUPP LOC EXHAUST MAY BE REQD.OTHER
SPEC PREC SUCH AS RESP MASKS OR ENVIRONMENTAL DEVICES MAY BE REQD
IN EXTREME CASES.CHLOROCARBON/CHLOROFLUOROCARBON(CFC) MATERIALS
HAVE PRODUCED SENSITIZATION OF THE MYOCARDIUM TO EPINEPHRINE IN LAB
ANIMALS AND COULD HAVE A SIMILAR (SEE ING 6).
Chemical Properties
HCC:V3
Boiling Pt:B.P. Text:156
Spec Gravity:<1
Solubility in Water:NEGLIGIBLE
Appearance and Odor:AMBER COLOR-STRONG SOLVENT ODOR.
Percent Volatiles by Volume:67
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:THIS PRODUCT IS INCOMPATIBLE WITH
OXIDIZING AGENTS, STRONG ACIDS AND BASES, AND SELECTED AMINES.
Hazardous Decomposition Products:CARBON MONOXIDE AND/OR CABRON DIOXIDE
AND TRACES OF PHOSGENE. HCL .
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL LOCAL, STATE
AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.