BLBPJ - CP-231 CHIL-FIX MF
- MSDS: BLBPJ
- Manufacturer: CHILDERS PRODUCTS CO INC
- Product Name: CP-231 CHIL-FIX MF
- National Stock Number: 8040-00N016335
Product Identification
Product ID:CP-231 CHIL-FIX MF
MSDS Date:01/01/1990
FSC:8040
NIIN:00N016335
MSDS Number: BLBPJ
Responsible Party
LEVITTOWN, PA 19057
US
Emergency Phone: 800-424-9300 (CHEMTREC)
Info Phone: 215-943-7600
Preparer: ROBERT ANDREWS
Cage: 3K675
Contractor
Cage: 3K675
Ingredients
HYDROCARBON PROPELLANT
CAS: 68476-86-8
Fraction By Weight: 29-33%
HEXANE (N-HEXANE)
CAS: 110-54-3
RTECS: MN9275000
Fraction By Weight: 20-25%
OSHA PEL 500 PPM
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
TOLUENE (SARA III)
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 5-8%
OSHA PEL 200 PPM/150 STEL
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE) (SARA III)
CAS: 71-55-6
RTECS: KJ2975000
Fraction By Weight: 0-25%
OSHA PEL 350 PPM/450 STEL
ACGIH TLV: 350 PPM/450STEL;9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
METHYLENE CHLORIDE (SARA III)
CAS: 75-09-2
RTECS: PA8050000
Fraction By Weight: 0-20%
OSHA PEL 500 PPM/C,1000; Z2
ACGIH TLV: 50 PPM, A2; 9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: VAP MAY CAUSE HDCH &/ DIZZ. LIQ
MAY CAUSE EYE INJURY. CHRONIC: VARIOUS STUDIES HAVE SHOWN A POSS
ASSOC W/EXPOS TO SOLV IN THIS PROD & THE FOLLOWING: RESP TRACT
IRRIT/LIVER DAM IN HUMANS/KIDNEY DAM IN HUMANS/NAUS/VOMIT. EYE:
MAY BE AN IRRIT. MAY CAUSE TRANSIENT IRRIT W/CORNEAL INJURY. SKIN:
(SEE EFTS OF OVEREXP).
Explanation of Carcinogenicity:DICHLOROMETHANE: GROUP 2B(IARC)
Effects of Overexposure:HLTH HAZ: MAY CAUSE SKIN IRRIT UPON PRLNG/RPTD
CONT. INHAL: HIGH VAP CONC(GREATER THAN APPROX 1000 PPM) ARE IRRIT
TO EYES/RESP TRACT, MAY CAUSE HDCH/DIZZ/ANESTH, & MAY HAVE OTHER
CNS EFTS. INGEST: PRO D HAS A LOW ORDER OF ACUTE ORL TOXICITY, BUT
MIN AMT ASPIR INTO LUNGS DURING INJEST MAY CAUSE SEV PULM INJURY OR
DEATH.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYE: FLUSH THOROUGHLY W/H*2O FOR AT LST 15 MIN. CALL MD
IMMED. SKIN: WASH THOROUGHLY W/SOAP/H*2O FOR AT LST 15 MIN. INHAL:
IF BRTHG DFCLT/DIZZ/LT HEAD OCCUR WHEN WORKING IN AREAS W/HIGH VAP
CONC, VICT IM SHOULD SEEK AIR FREE OF VAP. IF VICTIM EXPER
CONTINUED BRTHG, ADMIN O*2 UNTIL MED ASSIST CAN BE RENDRED. IF BRTH
STOPS, BEGIN ARTF RESP & SEEK IMMED MED ATTN. INGEST: IF SWALLOWED,
(SEE SUPP DATA).
Fire Fighting
Flash Point:<0
Lower Limits:1.0%
Upper Limits:8.0%
Extinguishing Media:FOAM,CO*2, OR DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT . AVOID SPREADING BURNING LIQUID WITH
WATER USED FOR COOLING PURPOSES.
Unusual Fire/Explosion Hazard:KEEP WORK AREAS FREE OF HOT METAL AND
OTHER SOURCES OF IGNITION. THERMAL DECOMP PRODUCTS MAY INCLUDE HCL
AND PHOSGENE .
Accidental Release
Spill Release Procedures:KEEP SOURCES OF IGNITION ISOLATED FROM THE
SPILL. AVOID SKIN CONTACT AND BREATHING OF VAPORS. VENTILATE AREA.
SCRAPE MATERIAL INTO CLOSED CONTAINERS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP TIGHTLY CLOSED IN
COOL/DRY/VENTILATED AREA. PROTECT FROM STATIC DISCHARGE. NO SMOKING
IN AREA OF USE. DO NOT USE IN GEN VICIN OF (SEE OTHER PROC)
Other Precautions:HNDLG/STOR PREC: ARC WELD, OPEN FLAMES/HOT SURF. HEAT
& UV RADIA MAY CAUSE FORMATION OF HCL AND/OR PHOSGENE . IF BULK OR
LG GAS CYLINDERS: MAY DISPLACE OXYGEN IN ENCLOSED/CONFINED SPACES.
GAS/VA P MAY ACCUMULATE IN LOW AREA .
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:GEN MECH VENT MAY BE SUFFICIENT TO KEEP PROD VAP CONC W/IN
TIMEWEIGHTED TLV RANGES. IF GEN VENT PROVES (SEE SUPP DATA).
Protective Gloves:IMPERMEABLE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:THE AVAILABILITY OF EYE WASHES & SFTY
SHOWERS IN WORK AREA IS RECOMND. THE USE OF IMPERMEABLE APRONS IS
RECOMMENDED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIR AID PROC:DO NOT INDUCE VOMIT.CALL MD IMMED.VENT:INADEQ TO MAINTN
SAFE VAP CONC, SUPPL LOC EXHAUST MAY BE REQD. OTHER SPEC PREC SUCH
AS RESP MASKS OR ENVRNMNTL DEVICES MAY BE REQD IN EXTREME CASES.
CHLOROCARBON/CHLOROFLUOROCARBON(CFC)MATLS HAVE PRDCED SENSITIZATION
OF THE MYOCARDIUM TO EPINEPHRINEIN LAB (SEE ING 6)
Chemical Properties
HCC:V3
Boiling Pt:B.P. Text:156
Spec Gravity:<1
Solubility in Water:NEGLIGIBLE
Appearance and Odor:AMBER COLOR-STRONG SOLVENT ODOR.
Percent Volatiles by Volume:67
Stability
Stability Indicator/Materials to Avoid:YES
THIS PRODUCT IS INCOMPATIBLE WITH OXIDIZING AGENTS, STRONG ACIDS AND
BASES, AND SELECTED AMINES.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE AND/OR CARBON DIOXIDE
AND TRACES OF PHOSGENE. HCL
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL FEDERAL, STATE
AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.