BLCBF - CER FLEX MODULES & SHAPES

  • MSDS: BLCBF
  • Manufacturer: C E REFRACTORIES
  • Product Name: CER FLEX MODULES & SHAPES
  • National Stock Number: 5640-00N017135
Product Identification

Product ID:CER FLEX MODULES & SHAPES
MSDS Date:11/01/1985
FSC:5640
NIIN:00N017135
MSDS Number: BLCBF

Responsible Party
C-E REFRACTORIES
VALLEY FORGE, PA 19482
US

Emergency Phone: 215-337-1100

Info Phone: 203-285-9693

Cage: 8C482

Contractor
C-E REFRACTORIES DIV OF COMBUSTION ENGINEERING
KING OF PRUSSIA, PA 19406 US

Telephone: 215-337-1100

Cage: 8C482

Ingredients

CERAMIC FIBER (ALUMINA SILICATE FIBER) TLV IS AS MINERAL

ACGIH TLV: 10 MG/M3 (RDUST)


PERMISSIBLE EXPOS LIMIT(PEL) MAY BE CALCULATED BY

RTECS: 9999999ZZ


FREE SILICA PLUS TWO, AVERAGED OVER AN 8 HOUR WORK

RTECS: 9999999ZZ


(TEAR OUT) DUST GENERATION IS LIKELY. THE USER

RTECS: 9999999ZZ


TO AVOID INHALAITON OF DUST.

RTECS: 9999999ZZ


2.0-5.0 F/CC - NIOSH APPRVD DISPOSABLE DUST


EFFICIENCY FILTER. >50.0 F/CC - NIOSH APPRVD FULL

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: IRRIT OF SKIN/UPPER RESP SYS.
PROD CAN CAUSE IRRIT TO EYES ON CONT/SKIN ON PRLNG CONT. CHRONIC:
CAN OCCUR FROM LONG TERM EXCESS INHAL OF CRYSTALLINE SILICA DUST.
CRYSTALLINE SILICA IN LUNGS CAN PRDC PNEUMOCCONIOSIS, COMMONLY
CALLED SILICOSIS, WHICH IS A SLOWLY DEVELOPING DISEASE. SYMP ARE
(SEE EFTS OF OVEREXP)
Explanation of Carcinogenicity:CRYSTALLINE SILICA: CLASS 2A (IARC).
SILICA FORMS AT TEMPS. OF 1000C. SEE HEALTH HAZARDS.
Effects of Overexposure:HLTH HAZ: USUALLY DELAYED (10 YEARS OR MORE).
SMOKING CAN INCR RISK OF INJURY. CERAMIC FIBER IS UNDER
INVESTIGATION AS A POSS ANIMAL CARCIN. ANIMAL STUDIES TO DATE ARE
INCONCLUSIVE. EXPOS TO DUST FROM PROD SHOULD BE MINIMIZED UNTIL
FURTHERANIMAL & HUMAN STUDIES ARE COMPLETE. PRODUCT IS SUSPECTED TO
BE ANIMAL (SUPDAT)
Medical Cond Aggravated by Exposure:PRE-EXISTING UPPER RESPIRATORY AND
LUNG DISEASES SUCH AS, BUT NOT LIMITED TO, BRONCHITIS, EMPHYSEMA
AND ASTHMA.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR. SUPPORT BRTHG. (GIVE O*2/ARTF
RESP) . INGEST: SEEK MD IMMED . EYES: FLUSH WITH WATER FOR AT LEAST
15 MIN. SKIN: WASH OFF THOROUGHLY USING MILD SOAP/WATER.

Fire Fighting

Flash Point:NON-COMBUSTIBLE
Extinguishing Media:USE EXTINGUISHING MEDIA APPROPRIATE TO SURROUNDING
FIRE CONDITIONS .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:PRODUCT IS A NON-COMBUSTIBLE REFACTORY.

Accidental Release

Spill Release Procedures:NONE SPECIFIED BY MANUFACTURER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NIOSH/MSHA APPRVD RESP SHOULD BE USED
FOR DUST LEVELS LESS THAN 10X PEL. DUST GENERATION SHOULD BE
MINIMIZED BY USE OF DUST CONTROL EQUIP/H*2O SPRAY.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED DUST RESPIRATOR WHERE DUST
LEVELS MAY BE EXCEEDED. AND WHEN AIRBORNE FIBER EXPOSURE LIMITS ARE
EXCEEDED. NIOSH/MSHA APPROVED BREATHING EQUIP MAY BE REQUIRED FOR
NON-ROUTINE AND EME RGENCY USE. (SEE INGRED 6)
Ventilation:PROVIDE ADEQ GEN & LOCAL EXHAUST VENT TO MEET PEL
REQUIREMENTS. VENT SHOULD BE USED TO CONTROL/REDUCE AIRBORNE CONC.
Protective Gloves:NONE SPECIFIED BY MANUFACTURER.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:WEAR PROTECTIVE CLOTHING AND VACUUM CLEAN
PRIOR TO REMOVING CLOTHING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP: CARCIN. TARGET ORGANS: LUNG/SKIN. CRYSTALLINE SILICA
(CRISTOBALITE) WILL FORM AFTER SERVICE AT TEMP 1000C."AFTER
SERVICE" DUSTS WILL TYPICALLY CONTAIN >20% CRISTOBALITE CAS
#144646-46 -1(CRYSTALLINE SILICA) WHICH CAN PRESENT A HLTH HAZ IF
INHALED OVER LONG PERIODS OF TIME. CURRENT OSHA (INGRED 2)

Chemical Properties

HCC:T6
Appearance and Odor:WHITE TO OFF-WHITE FIBER MODULES, NO ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CRYSTALLINE SILICA (CRISTOBALITE) WILL
FORM AFTER SERVICE AT TEMP OF 1000C.

Disposal

Waste Disposal Methods:SOLID WASTE REGULATION APPLY. CONSULT LOCAL,
STATE AND FEDERAL REGULATORY AGENCIES TO DETERMINE BEST DISPOSAL
ALTERNATIVES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.