BLCDC - OMC HI-VIS GEAR LUBE, 31-250

  • MSDS: BLCDC
  • Manufacturer: CITGO PETROLEUM CORP
  • Product Name: OMC HI-VIS GEAR LUBE, 31-250
  • National Stock Number: 9150-00N017188
Product Identification

Product ID:OMC HI-VIS GEAR LUBE, 31-250
MSDS Date:05/08/1989
FSC:9150
NIIN:00N017188
MSDS Number: BLCDC

Responsible Party
CITGO PETROLEUM CORPORATION
TULSA, OK 74102
US

Emergency Phone: 318-491-6215;800-424-9300(CHEMTREC)

Info Phone: 918-495-5933

Cage: 7X110

Contractor
CITGO PETROLEUM CORP
3758 TULSA, OK 74102 US

Telephone: 918-495-5933

Cage: 7X110

Ingredients

REFINED PETROLEUM OIL(S) MIXTURE CONSISTING OF INGREDIENTS

RTECS: 9999999ZZ

Fraction By Weight: 97-99%


MINERAL OIL, PETRO DISTIL, SOLVENT-REFINED HEAVY PARAFFINIC

CAS: 64741-88-4

RTECS: PY8040500

OSHA PEL 5 MG/M3 (OIL MIST)

ACGIH TLV: 5 MG/M3 (OIL MIST)


REFINED PETROLEUM OIL

CAS: 64742-01-4


EXTREME PRESSURE, OXIDATION AND RUST INHIBITOR (MIXTURE).

Fraction By Weight: 1-4%


VI IMPROVER

Fraction By Weight: <0.1%


IF NOT FAMILIAR WITH TECHNIQUE, SEEK SKILLED

RTECS: 9999999ZZ


SLIGHTLY TOXIC, 1 PT TO 1 QT IS

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:SEE INGREDIENT 07
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: LOW RISK OF INHALATION.
IN ENCLOSED SPACES OR WHEN HOT, VAPORS MAY REACH CONCENTRATIONS
SUFFICIENT TO CAUSE DROW, DIZZ, HDCH, NAUS, OR LUNG IRRITATION.
MISTS ABOVE TLV MAY CAUSE CHEMICAL PNEUMONITIS. SKIN: LOW
IRRITANT. ABSORP: NO PROBABLE ACUTE HAZARD. EYE: MAY BE MILDLY
IRRITATING. (SEE EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: INGEST: GENERALLY LOW TOXICITY. VERY
LARGE AMOUNTS MAY CAUSE GENERALIZED DEPRESSION, HDCH, DROW, NAUS,
VOMIT OR DIARR. SMALL DOSES MAY PRODUCE IRRITATION AND DIARRHEA.
INJECT: ERYTHEMA, EDEM A, IRRITATION. CHRONIC: PROLONGED AND/OR
FREQUENT CONTACT MAY CAUSE DRYING, CRACKING (DERMATITIS) OR
FOLLICULITIS.
Medical Cond Aggravated by Exposure:NONE.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR. RESPIRATORY SUPPORT IF NECESSARY.
SEEK MEDICAL AID. SKIN: WASH WITH SOAP AND WATER. DO NOT WEAR
HEAVILY CONTAMINATED CLOTHING BEFORE LAUNDERING. EYES: FLUSH WITH
LARGE VOLU MES OF WATER. SEE MD IF ANY COMPLICATIONS ARISE. INGEST:
DO NOT INDUCE VOMITING. SEEK MEDICAL AID. INJECT: SUBCUTANEOUS
INJECTION IS A MEDICAL EMERGENCY. SEEK MEDICAL AID IMMEDIATELY.
(SEE SUPP DATA)

Fire Fighting

Flash Point Method:COC
Flash Point:460F,238C
Extinguishing Media:CO*2, DRY CHEMICAL, FOAM, WATER FOG
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:WATER MAY CAUSE FROTHING.

Accidental Release

Spill Release Procedures:REMOVE HEAT/IGNIT SOURCES, PROVIDE ADEQ VENT,
CNTN LEAK. SM SPILLS: ABSORB W/SUITABLE MATL SUCH AS
RAGS/STRAW/SAND. LG SPILLS: CNTN SPILL IN EARTHEN DIKES FOR LATER
RECOVERY. RPT SPILLS AS REQD TO APP ROP AUTH.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE BELOW 150F. DO NOT APPLY HIGH
HEAT OR FLAME TO CONTAINER. KEEP SEPARATE FROM STRONG OXIDIZING
AGENTS.
Other Precautions:EMPTY CNTNRS MAY CNTN PROD RESIDUE WHICH COULD INCL
FLAMM/EXPLO VAPS. CNSLT APPROP FED, STATE & LOCAL AUTH BEFORE
REUSING, RECONDITIONING, RECLAIMING, OR RECYCLING EMPTY CNTNRS
AND/OR WASTE RESIDUES O F PROD. AVOID PRLNG CNTCT W/USED OIL.

Exposure Controls

Respiratory Protection:NORMALLY NONE REQUIRED. IF HIGH VAPOR OR MIST
CONCENTRATIONS EXPECTED, USE RESPIRATOR APPROVED BY NIOSH/MSHA FOR
ORGANIC VAPORS AND MISTS.
Ventilation:USE IN WELL VENTED AREA. CONFINED SPACE: MECH VENT MAY BE
REQD TO KEEP LEVELS OF CERTAIN COMPONENTS BELOW MANDATED STDS.
Protective Gloves:OIL IMPERVIOUS.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:WEAR BODY-COVERING WORK CLOTHES TO AVOID
PROLONGED OR REPEATED EXPOSURE.
Work Hygienic Practices:WASH EXPOSED SKIN THOROUGHLY WITH SOAP AND
WATER. REMOVE AND LAUNDER SOILED WORK CLOTHES BEFORE REUSE.
Supplemental Safety and Health
FIRST AID PROC: NOTE TO MD: IF VISC IS <100 SUS @100F, CAREFUL GASTRIC
LAVAGE W/TIGHT FITTING/CUFFED TUBE IS TO BE PREFERRED OVER EMESIS.
IF VISC IS >100 SUS @100F, EMESIS MAY BE INDUCED FOR LG QTYS.
ASPIR MAY CAUSE CHEM PNEUMIT/LIPOID PNEUMONIA. SUBCUTANEOUS
INJECTION REQS PROMPT SURG DEBRIDEMENT. (SEE INGRED 06)

Chemical Properties

HCC:V6
Boiling Pt:B.P. Text:750F,399C
Vapor Pres:<3 X 10E4
Vapor Density:>1
Spec Gravity:0.89
Evaporation Rate & Reference:<1 (BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:AMBER LIQUID, SLIGHT SULFURIZED ODOR.
Percent Volatiles by Volume:NEGLIG

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:THERMAL: CO*2 (CO UNDER INCOMPLETE
COMBUSTION).

Disposal

Waste Disposal Methods:THE USER MUST DETERMINE IF THE MATL IS A HAZ
WASTE AT THE TIME OF DISP. CHECK BEFORE DISPOSING TO BE SURE YOU
ARE IN COMPLIANCE W/ALL APPLIC LAWS & REGS. CHEMTREC/RCRA EMER
HOTLINE: 800-424-9346. CNSL T APPROP FED, STATE & LOCAL AUTH
BEFOREDISP PROD.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.