BLCPD - GREAT DAY I00201 ALUM

Product Identification

Product ID:GREAT DAY I00201 ALUM
MSDS Date:09/28/1990
FSC:8010
NIIN:00N018501
MSDS Number: BLCPD

Responsible Party
ILLINOIS BRONZE PAINT COMPANY
26400 FARGO AVENUE
BEDFORD HTS, OH 44146
US

Emergency Phone: 216-292-7400

Info Phone: 216-292-7400

Cage: 91794

Contractor
ILLINOIS BRONZE PAINT COMPANY
LAKE ZURICH, IL 60047-2580 US

Telephone: 800-228-5635

Cage: 91794

Ingredients

1.0

CAS: 64742-95-6

Fraction By Weight: <5%


2-BUTOXYETHANOL

CAS: 111-76-2

RTECS: KJ8575000

Fraction By Weight: <5%

OSHA PEL S, 50 PPM

ACGIH TLV: S, 25 PPM; 9293


ETHYL TOLUENE

CAS: 25550-14-5

Fraction By Weight: <5%


TOLUENE (SARA III)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 55%

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


1.8

CAS: 75-28-5

RTECS: TZ4300000

Fraction By Weight: 15%

OSHA PEL 1000 PPM (MFR)

ACGIH TLV: 1000 PPM (MFR)


PROPANE

CAS: 74-98-6

RTECS: TX2275000

Fraction By Weight: 15%

OSHA PEL 1000 PPM

ACGIH TLV: ASPHYXIANT; 9192


ALUMINUM (SARA III)

CAS: 7429-90-5

RTECS: BD0330000

Fraction By Weight: <5%

OSHA PEL 15MG/M3 DUST/5 FUME

ACGIH TLV: 10MG/M3 DUST; 9192

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:IN CONFINED AREA VAPS IN HIGH CONC ARE
ANESTHETIC. IRRIT TO SKIN AND UPPER RESP SYSTEM. OVEREXPOS MAY
RESULT IN LIGHT-HEADEDNESS, STAGGERING GAIT, GIDDINESS AND POSS
NAUS. HARMFUL OR FATAL IF SWALLOWE D. CHRONIC: REPORTS HAVE ASSOC
REPEATED& PRLNGD OVREXPS TO SOLVENTS W/PERM BRAIN & NERVOUS SYSTEM
DMG (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HEALTH HAZARDS: AND KIDNEY/LIVER DAMAGE. ANIMAL
STUDIES CLEARLY DEMONSTRATE DOSE-RELATED ADVERSE EFFECTS ON CNS,
HEMOTOPOIETHIC TISSUES, BLOOD, KIDNEYS, LIVER ASSOCIATED WITH
ADMINISTRATION OF EGBE.(N IOSH PUB #90-118).
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. SKIN: WASH
WITH SOAP AND WATER. INHAL: REMOVE PATIENT TO FRESH AIR. INGEST:
CALL PHYSICIAN IMMEDIATELY. DO NOT INDUCE VOMITING.

Fire Fighting

Flash Point Method:TOC
Flash Point:<20F,<-7C
Lower Limits:SEE INGS
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA AND FULL
PROTECTIVE EQUIPMENT. DO NOT SPRAY NEAR OPEN FLAME. EXPOS TO DIRECT
SUNLIGHT/HEAT MAY CAUSE BURSTING.
Unusual Fire/Explosion Hazard:WATER MAY BE INEFFECTIVE. USE WATER TO
KEEP FIRE EXPOSED CONTAINERS COOL.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION, VENTILATE
AVOID BREATHING VAPORS AND REMOVE WITH INERT ABOSRBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 120F. KEEP AT ROOM
TEMPERATURE AS EXPOSURE TO DIRECT SUNLIGHT OR HEAT MAY CAUSE
BURSTING.
Other Precautions:KEEP AWAY FROM CHILDREN. DO NOT PUNCTURE OR
INCINERATE. DO NOT SPRAY NEAR FIRE OR OPEN FLAME.

Exposure Controls

Respiratory Protection:AVOID BREATHING VAPOR/SPRAY MIST. IF EXPOSURE >
APPLICATION LIMITS, WEAR NIOSH/MSHA APPROVED ORGANIC
VAPOR/PARTICULATE RESPIRATOR. WHEN SANDING/ABRADING DRIED FILM,
WEAR NIOSH/MSHA RESPIRATOR FOR APPL ICABLE DUSTS.
Ventilation:PROVIDE LOCAL EXHST VENT IN VOLUME & PATTERN TO KEEP TLV OF
ALL HAZ INGREDIENTS BELOW ACCEPTABLE LIMITS.
Protective Gloves:IMPERVIOUS GLOVES
Eye Protection:CHEMICAL WORKERS GOGGLES
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

HCC:V3
Boiling Pt:B.P. Text:<0F,<-18C
Vapor Density:HVR AIR
Evaporation Rate & Reference:FASTER THAN ETHER
Appearance and Odor:COATINGS
Percent Volatiles by Volume:92 WT

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:DO NOT STORE ABOVE 120F.
Hazardous Decomposition Products:BY OPEN FLAME: CO, CO2

Disposal

Waste Disposal Methods:DO NOT INCINERATE - DISPOSE IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL REGULATIONS REGARDING POLLUTION.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.