BLCVL - STRIP IT

Product Identification

Product ID:STRIP IT
MSDS Date:09/22/1988
FSC:8010
NIIN:00N019476
MSDS Number: BLCVL

Responsible Party
SUNSHINE CHEMICAL SPECIALTIES INC
PENNSAUKEN, NJ 08110
US

Emergency Phone: 609-488-1111

Info Phone: 609-488-1111

Preparer: M HASKELL

Cage: 69114

Contractor
SUNSHINE CHEMICAL SPECIALITIES INC
PENNSAUKEN, NJ 08110 US

Telephone: 609-488-1111

Cage: 69114

Ingredients

METHYLENE CHLORIDE (SARA III)

CAS: 75-09-2

RTECS: PA8050000

Fraction By Weight: 70%

OSHA PEL 500 PPM/C,1000; Z2

ACGIH TLV: 50 PPM, A2; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


SOLVENT NAPHTHA; (AROMATIC PETROLEUM NAPTHA)

CAS: 64742-94-5

RTECS: WF3100000

Fraction By Weight: 20%

ACGIH TLV: 200 PPM (MFR)


PHENOL

CAS: 108-95-2

RTECS: SJ3325000

Fraction By Weight: 5%

OSHA PEL 5 PPM, S

ACGIH TLV: 5 PPM, S

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


NONIONIC DETERGENT

CAS: 68412-54-4

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:(ACUTE) EYE IRRITATION, SKIN
IRRITATION, STOMACH IRRITATION. INHALATION CAN CAUSE BRONCHIAL
IRRITATION. (CHRONIC) REDNESS OF EYES AND SKIN, NAUSEA, DIZZINESS,
DROWSINESS. LIVER AND KIDNEY DISEASE. CHL OROCARBON MATLS HAVE
PRODUCED SENSITIZATION OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS
AND COULD (SEE EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE: IARC GROUP 2B, ACGIH
GROUP A2. NTP KNOWN ANIMAL CARCINOGEN/SUSPECTED HUMAN CARCINOGEN.
Effects of Overexposure:HLTH HAZ: HAVE A SIMILAR EFFECT IN HUMANS.
ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT
FOR LIFE- SUSTAINING USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED
TO CHLOROCARBONS .
Medical Cond Aggravated by Exposure:CONJUNCTIVITIS, DERMATITIS,
DIARRHEA, BRONCHITIS.

First Aid

First Aid:EYES: WASH WITH WATER FOR AT LEAST 15 MINUTES. CALL MD. SKIN:
WASH WITH WATER FOR 10-15 MINUTES. GET MD IF IRRITATION PERSISTS
MORE THAN 24 HOURS. INGEST: GET MD. DO NOT INDUCE VOMITING. INHAL:
GET FR ESH AIR, FOR SEVERE DROWSINESS ADMINISTER ARTIFICIAL
RESPIRATION. GET MD.

Fire Fighting

Flash Point Method:TCC
Flash Point:NONE
Extinguishing Media:NON-FLAMMABLE. USE MEDIA SUITABLE FOR SURROUNDING
FIRE .
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA &
FULL PROTECTIVE EQUIPMENT . KEEP CONTAINERS COOL TO AVOID BURSTING
AND VAPOR ODORS.
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL AND PHOSGENE .

Accidental Release

Spill Release Procedures:VENTILATE AREA, WEAR PROTECTIVE GEAR. CONTAIN
SPILL AND TRANSFER TO SEALABLE CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN COOL AREA. KEEP CONTAINERS
CLOSED.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR
UV RADIATION MAY CAUSE THE FORMATION OF HCL AND/OR PHOSGENE .

Exposure Controls

Respiratory Protection:USE IN WELL VENTILATED AREA. NIOSH/MSHA APPROVED
RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST. VENTILATE TO KEEP ODORS BELOW TLV.
Protective Gloves:CHEMICAL RESISTANT.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:IF SPILLAGE OCCURS, WEAR CHEMICAL RESISTANT
APRON AND BOOTS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

HCC:T4
Boiling Pt:B.P. Text:103F,39C
Vapor Pres:390
Vapor Density:>1
Spec Gravity:1.30+/-0.005
Evaporation Rate & Reference:FASTER THAN WATER
Solubility in Water:EMULSIFIABLE
Appearance and Odor:CLEAR TAN LIQUID, CHLORINATED SOLVENT ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:EXPOSURE TO FLAME OR HIGH HEAT MAY
PRODUCE CO, CH20, HCL. PHOSGENE .

Disposal

Waste Disposal Methods:RE-USE IF POSSIBLE. INCINERATE IN LICENSED
FACILITY. DISPOSE IN LICENSED CHEMICAL LANDFILL. SEND TO LICENSED
RECLAIMER. DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.