BMSZW - 109300-10 INFLATOR ASSEMBLY
- MSDS: BMSZW
- Manufacturer: S TRON
- Product Name: 109300-10 INFLATOR ASSEMBLY
- National Stock Number: 4220-01-302-2560
Product Identification
Product ID:109300-10 INFLATOR ASSEMBLY
MSDS Date:02/20/1992
FSC:4220
NIIN:01-302-2560
MSDS Number: BMSZW
Responsible Party
MOUNTAIN VIEW, CA 94043
US
Emergency Phone: 415-903-4949
Info Phone: 415-903-4949
Cage: 2J495
Contractor
Telephone: 415-903-4949
Cage: 2J495
Ingredients
BLACK POWDER
LEAD STYPHANATE INITIATING EXPLOSIVE
CAS: 15245-44-0
OSHA PEL 0.05 MG/M3 (PB)
ACGIH TLV: 0.15 MG/M3 (PB)
Hazards
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:THE PYROTECHNIC DEVICE IS SEALED IN A
PLASTIC HOUSING, THUS PREVENTING CONTACT AT TIME OF FUNCTION.
Fire Fighting
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM, OR DRY
CHEMICAL.
Fire Fighting Procedures:WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND A
FULL FACED SELF CONTAINED BREATHING APPARATUS. COOL FIRE EXPOSED
CONTAINERS WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:COMBUSTION OR HEAT OF FIRE MAY PRODUCE
HAZARDOUS DECOMPOSITION PRODUCTS AND VAPORS.
Accidental Release
Spill Release Procedures:COLLECT UNITS, AND REPACKAGE.
Handling
Handling and Storage Precautions:AVOID ROUGH HANDLING. DO NOT STORE IN
TEMPERATURES EXCEEDING 160F.
Other Precautions:UNITS WILL ACTIVATE WHEN IMMERSED IN WATER. NO CHANGE
IN EXTERNAL APPEARANCE AFTER ACTIVATION. UNITS CONTAIN ALKALINE
BATTERIES. DO NOT ATTEMPT TO RECHARGE. DISPOSE OF PROPERLY.
Exposure Controls
Respiratory Protection:NONE
Ventilation:NONE
Protective Gloves:NONE
Eye Protection:NONE
Other Protective Equipment:NONE
Work Hygienic Practices:NONE
Supplemental Safety and Health
NONE
Chemical Properties
HCC:E2
Appearance and Odor:RECTANGULAR SHAPE PLASTIC (3.8" X 2.4" X 1.1") WITH
SOME METAL PARTS. NO ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:AVOID FLAMES, TEMPERATURES OVER 160F,
STATIC ENERGY, ELECTRICAL ENERGY. DO NOT DISASSEMBLE.
Disposal
Waste Disposal Methods:NOTIFY YOUR LOCAL ENVIRONMENTAL OFFICER. USE
DISPOSAL METHODS APPROVED FOR PYROTECHNIC DEVICES. ACTIVATION OF
THE DEVICE CAN BE ACCOMPLISHED BY IMMERSION IN WATER. FOLLOW ALL
APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.