BNBLP - N-450-9 THINNER/CLEANER
- MSDS: BNBLP
- Manufacturer: HAARTZ MASON INC
- Product Name: N-450-9 THINNER/CLEANER
- National Stock Number: 8010-00N028839
Product Identification
Product ID:N-450-9 THINNER/CLEANER
MSDS Date:12/01/1989
FSC:8010
NIIN:00N028839
MSDS Number: BNBLP
Responsible Party
WATERTOWN, MA 02172
US
Emergency Phone: 201-694-0845;800-645-8265
Info Phone: 201-694-0845;617-926-2300
Cage: IO136
Contractor
Telephone: 617-926-2300
Cage: 84697
Ingredients
XYLENE
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: 50.0%
OSHA PEL 100 PPM;150 PPM STEL
ACGIH TLV: 100 PPM;150 PPM STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
2-BUTANONE; (METHYL ETHYL KETONE)
CAS: 78-93-3
RTECS: EL6475000
Fraction By Weight: 50.0%
OSHA PEL 200 PPM;300 PPM STEL
ACGIH TLV: 200 PPM;300 PPM STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: VAPORS MAY BE AN IRRITANT.
DIRECT LIQUID CONTACT CAUSES SEVERE IRRITATION & INJURY. SKIN: MAY
CAUSE IRRITATION AND DERMATITIS UPON PROLONGED OR REPEATED USE.
INHAL: RESPIRATORY TRACT IRRITANT AN D ANESTHETIC. MAY CAUSE
NARCOSIS IN HIGH CONC. CAUSES CNS DEPRESSION. INGEST: MAY CAUSE
LIVER (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: AND/OR KIDNEY DAMAGE.
Medical Cond Aggravated by Exposure:ANY ALLERGY, ECZEMA, SKIN
CONDITION, PREEXISTING HEART OR LUNG DISORDER. PREEXISTING LIVER OR
KIDNEY DISORDER.
First Aid
First Aid:EYES: FLUSH WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15 MIN.
CONSULT PHYS. SKIN: WASH THOROUGHLY WITH SOAP AND WATER. INHAL:
REMOVE TO FRESH AIR. IF BREATHING STOPS, APPLY ARTIFICIAL
RESPIRATION AND C ONSULT PHYS. INGEST: CONSULT PHYS. NEVER GIVE
ANYTHING BY MOUTH TO AN UNCON PERSON.
Fire Fighting
Flash Point Method:SCC
Flash Point:32.0F,0.0C
Lower Limits:1.0%
Upper Limits:11.5%
Extinguishing Media:USE FOAM, CO2 OR DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:SOLVENT VAPORS MAY TRAVEL CONSIDERABLE
DISTANCES AND FLASH BACK FROM SOURCE OF IGNITION.
Accidental Release
Spill Release Procedures:ABSORB ON SUITABLE INERT MATERIAL. REMOVE ALL
SOURCES OF IGNITION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP AND STORE IN COOL, DRY PLACE AWAY
FROM SOURCES OF IGNITION. GROUND DURING TRANSFER.
Other Precautions:REPEATED AND PROLONGED OVEREXPOSURE TO SOLVENTS MAY
CAUSE BRAIN AND NERVOUS SYSTEM DAMAGE. CONCENTRATING AND INHALING
CONTENTS MAY BE HARMFUL OR FATAL.
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED CARTRIDGE RESPIRATOR
UNLESS AIR MONITORING DEMONSTRATES THAT VAP/MIST LEVELS ARE WITHIN
APPLICABLE LIMITS.
Ventilation:MECHANICAL.
Protective Gloves:IMPERMEABLE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:AVAILABILITY OF EYEWASHES AND SAFETY SHOWERS
IS RECOMMENDED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Chemical Properties
HCC:F3
Boiling Pt:B.P. Text:175F,79C
Vapor Pres:>1
Vapor Density:>1
Spec Gravity:0.84
Evaporation Rate & Reference:>1(BUTYL ACETATE=1)
Solubility in Water:PARTIAL
Appearance and Odor:COLORLESS, CLEAR LIQUID WITH CHARACTERISTIC ODOR.
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS, STRONG ACIDS OR BASES, HALOGENS.
Stability Condition to Avoid:SPARKS, OPEN FLAMES OR HOT SURFACES.
Hazardous Decomposition Products:CO AND CO2.
Disposal
Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH APPLICABLE LOCAL,
STATE AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.