Product Identification

Product ID:7811 MACHINERY GRAY, FAST DRY ACRYLIC ENAME
MSDS Date:06/01/1991
FSC:8010
NIIN:00N028934
MSDS Number: BNBND

Responsible Party
MARTIN-SENOUR CO
101 PROSPECT AVE NW
CLEVELAND, OH 44115
US

Emergency Phone: 216-566-2917

Info Phone: 216-566-2902

Cage: MART2

Contractor
SHERWIN-WILLIAMS CO THE
CLEVELAND, OH 44115-1042 US

Telephone: 800-251-2486/216-566-2242

Cage: 54636

Ingredients

FILM, WEAR PARTICULATE RESPIRATOR FOR PROTECTION

RTECS: 9999999ZZ


AUTOIGNITION OR EXPLOSIO WHEN EXPOSED TO

RTECS: 9999999ZZ


LIMITS. REFER TO OSHA STANDARDS 1910.94, 1910.107,

RTECS: 9999999ZZ


760.

CAS: 74-98-6

RTECS: TX2275000

Fraction By Weight: 13%

OSHA PEL 1000 PPM

ACGIH TLV: SIMPLE ASPHYXIANT


760

CAS: 75-28-5

RTECS: TZ4300000

Fraction By Weight: 14%


TOLUENE (SARA III)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 12%

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


7.1.

CAS: 100-41-4

RTECS: DA0700000

Fraction By Weight: 4%

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


5.9.

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 16%

OSHA PEL 100 PPM;150 PPM STEL

ACGIH TLV: 100 PPM;150 PPM STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


3.8.

CAS: 64742-95-6

Fraction By Weight: 2%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM


180

CAS: 67-64-1

RTECS: AL3150000

Fraction By Weight: 21%

OSHA PEL 1000PPM

ACGIH TLV: 750PPM/1000STEL;9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


TITANIUM OXIDE;(TITANIUM DIOXIDE)

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: 5%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


RADIATORS, STOVES, HOT WATER & OTHER HEAT SOURCES

RTECS: 9999999ZZ


USE ONLY WITH ADEQUATE VENTILATION. AVOID BREATHING

RTECS: 9999999ZZ


INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING &

RTECS: 9999999ZZ


CAS 108-88-3 APPEARS ON THE NAVY LISTING OF OCCUP

RTECS: 9999999ZZ


PROFESSIONAL CONCERN LATEST HAZ LIST INFO AND SAFE

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:ALCOHOLS & ACETATES CAN BE
ABSORBED THRU SKIN. IRRITAITON OF EYES, SKIN & RESP SYS. MAY CAUE
NERV SYS DEPRESS. EXTREME OVEREXP MAY RSLT IN UNCON, & POSS DEATH.
HDCH, DIZZ, NAUS, & LOSS OF COORD ARE INDICATIONS OF EXCESSIVE
EXPOS TO VAPS/SPRAY MISTS. REDNESS/ ITCHING OR BURNING SENSATION
MAY (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:INDICATE EYE OR EXCESSIVE SKIN EXPOS.
CHRONIC:PRLNGD OVEREXP TO SOLV INGREDS MAY CASUE ADVERSE EFTS TO
LIVER, URINARY, BLOOD FORMING, CNS/REPROD SYS. RATS EXPOSED TO
TITANIUM DIOXIDE DUST AT 250 MG/M3 DEVELOPED LUNG CANCER, BUT SUCH
LEVELS ARE NOT ATTAINABLE IN WORKPLACE. RPTS HAVE ASSOC RPTD/PRLNGD
(SUPDAT)
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.

First Aid

First Aid:INHAL:MOVE FROM EXPOSURE. RESTORE BREATHING. KEEP WARM &
QUIET. SKIN:WASH THOROUGHLY WITH SOAP & WATER. REMOVE CONTAMINATED
CLOTHING AND LAUNDER BEFORE RE-USE. EYE:FLUSH WITH LARGE AMOUNTS OF
WATER FO R AT LEAST 15 MINUTES. GET MD. INGEST:NEVER GIVE ANYTHING
BY MOUTH TO AN UNCONSCIOUS PERSON. DO NOT INDUCE VOMITING. GIVE
SEVERAL GLASSES OF WATER. GET MD.

Fire Fighting

Flash Point Method:PMCC
Flash Point:<0F,<-18C
Lower Limits:0%
Upper Limits:6%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. WATER SPRAY MAY BE INEFTIVE BUT MAY BE USED TO COOL CLSD CNTNRS
TO PVNT PRESS BUILD-UP & POSS (ING 16)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPARKS, & OPEN FLAME. CLSD CNTNRS MAY EXPLODE
WHEN EXPOSED TO EXTREME HEAT. APPLIC TO HOT (SUPP DATA)

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:CONTENTS UNDER PRESSURE. DO NOT
PUNCTURE, INCINERATE OR EXPOSE TO TEMPS ABOVE 120F. KEEP AWAY FROM
HEAT, SPARKS, & OPEN FLAME.
Other Precautions:VAPS WILL ACCUMULATE & IGNITE EXPLO. DURING USE &
UNTIL ALL VAPS ARE GONE:KEEP AREA VENT-DO NOT SMOKE-EXTING ALL
FLAMES, PILOT LIGHTS, & HEATERS-TURN OFF STOVES, ELEC TOOLS &
APPLIANCES & ANY OTHER IG NIT SOURCES. USE APPRVD (SUPP DATA)

Exposure Controls

Respiratory Protection:ALL RESPS MUST BE NIOSH/MSHA APPRVD. IF PERS
EXPOS CANNOT BE CNTRLD BELOW APPPLIC LIMITS BY VENT, WEAR A
PROPERLY FITTED NIOSH/MSHA APPRVD ORGANIC VAP/PARTICULTE RESP. WHEN
SANDING, WIREBRUSHING, ABRA DING, BURNING OR WELDING DRIED (ING 15)
Ventilation:LOCAL EXHAUST PREFERRABLE. GENERAL EXHAUST ACCEPTABLE IF
EXPOS TO INGREDS IS MAINTAINED BELOW APPLIC EXPOS (ING 14)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
MFR PT#/TRADE NAME:7800/N1. EXPLO HAZ: SURFACES REQUIRES SPECIAL
PRECAUTIONS. DURING EMERGENCY CONDITIONS OVEREXPOSURE TO DECOMP
PRODUCTS MAY CAUSE A HLTH HAZ. SYMPS MAY NOT BE IMMED APPARENT. GET
MD. EFTS OF OVEEXP:OVEREXP TO SOLVS W/PERMBRAIN & NERV SYS DMG.
OTHER PREC:BONDING/GROUNDING PROC. HEAT FROM (ING 9)

Chemical Properties

HCC:V3
Boiling Pt:B.P. Text:<360F,<182C
Vapor Density:HVR/AIR
Evaporation Rate & Reference:FASTER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:>75

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY FIRE:CO, CO2, OXIDES OF METALS IN
INGREDIENTS SECTION.

Disposal

Waste Disposal Methods:WASTE MAY BE HAZ AS DEFINED UNDER RCRA 40 CFR
261. WASTE MUST BE TESTED FOR IGNIT TO DETERMINE APPLIC EPA HAZ
WASTE NUMBERS. DO NOT INCINERATE. DEPRESSURIZE CONTAINER. DISPOSE
OF I/A/W FEDERAL, STATE, AND LOCAL REGULATIONS REGARDING
POLLUTION.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.