BNBSY - FM 123-5 ADHESIVE FILM
- MSDS: BNBSY
- Manufacturer: AMERICAN CYANAMID CO
- Product Name: FM 123-5 ADHESIVE FILM
- National Stock Number: 8040-01-060-3085
Product Identification
Product ID:FM 123-5 ADHESIVE FILM
MSDS Date:06/26/1990
FSC:8040
NIIN:01-060-3085
MSDS Number: BNBSY
Responsible Party
WAYNE, NJ 07470
US
Emergency Phone: 201-835-3100
Info Phone: 201-835-3100
Preparer: MARVIN A. FRIEDMAN
Cage: 06904
Contractor
Telephone: 201-835-3100
Cage: 06904
Ingredients
FIBERGLASS
Fraction By Weight: 0-20%
OSHA PEL 15 MG/M3(TOTAL DUST)
ACGIH TLV: 10 MG/M3 (DUST)
(ORAL
CAS: 78-93-3
RTECS: EL6475000
Fraction By Weight: 0-0.5%
OSHA PEL 200 PPM;300 STEL
ACGIH TLV: 200 PPM;300 STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
METHANE, DICHLORO-;(METHYLENE CHLORIDE) (SARA III).
CAS: 75-09-2
RTECS: PA8050000
Fraction By Weight: 0-0.5%
OSHA PEL 500 PPM;1000 PPM,C
ACGIH TLV: 50 PPM
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
THIS RESPONSE WAS NOT SEEN IN RATS OR HAMSTERS
RTECS: 9999999ZZ
IN DRINKING WATER FOR 2 YEARS SHOWED NO SIGN OF
RTECS: 9999999ZZ
DIFFERS FROM RATS, HAMSTERS & HUMANS AT INHAL CONC OF
RTECS: 9999999ZZ
THESE HIGH EXPOS CONC HAS BEEN ASSOC W/CARC EFTS, AND
RTECS: 9999999ZZ
BIRTH DEFECTS WERE OBSERVED IN ANIMAL STUDIES, &
RTECS: 9999999ZZ
WAS OBSERVED IN RATS EXPOSED TO CONC GREATER THAN 200
RTECS: 9999999ZZ
MATLS HAVE PRODUCED SENSIT OF MYOCARDIUM TO
RTECS: 9999999ZZ
ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE
RTECS: 9999999ZZ
ACUTELY OR CHRONICALLY EXPOSED TO CHLOROCARBONS .
RTECS: 9999999ZZ
CAUSE THE FORMATION OF HCL AND/OR PHOSGENE .
RTECS: 9999999ZZ
FABRICATED AFTER CURING OF MATL MAY CREATE RESP
RTECS: 9999999ZZ
SEE "GUIDE TO INDUSTRIAL RESPIRATORY PROTECTION"
RTECS: 9999999ZZ
SPRAYING OR CURING AT ELEVATED TEMPERATURES.
RTECS: 9999999ZZ
SAFETY SHOWER.
RTECS: 9999999ZZ
DRINKING, OR SMOKING, WASH FACE & HANDS
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:SEE INGREDIENTS.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:BASED ON PHYSICAL FORM OF PRODUCT,
OVEREXP BY INGEST OR INHAL ROUTE UNLIKELY. ALLERGIC SKIN RXNS OR
PRIMARY SKIN IRRIT MAY BE PRODUCED BY PRLNGD/RPTD DERM CNTCT
W/EPOXY RESINS. OVEREXP TO VAP DURING H EAT CURING MAY CAUSE IRRIT
OR INJURY OFRESP TRACT & EYE IRRIT. FIBERGLASS IS CONSIDERED
NUISANCE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE:GROUP 2 (NTP), GROUP
2B (IARC).
Effects of Overexposure:HLTH HAZ:PARTICULATE WHICH WILL NOT CAUSE
ADVERSE HLTH EFTS OTHER THAN RESP CONGESTION/IRRIT. ACUTE OVEREXP
TO 2-BUTANONE (MEK) VAP MAY CAUSE EYE/RESP IRRIT & CNS DEPRESS
RSLTG IN HDCH, NAUS, DIZZ & S TAGGERING GAIT. IF SPLASHED INTO EYE,
MEK IS SEVERE IRRIT, & SKIN CNTCT MAY CAUSE MOD IRRIT. RPTD OVEREXP
TO(SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYE:IMMEDIATELY IRRIGATE WITH PLENTY OF WATER FOR AT LEAST 15
MINUTES. GET MD IF IRRITATION PERSISTS. INHAL:MOVE TO FRESH AIR.
SUPPORT BREATHING (GIVE O*2/ARTF RESP) . SKIN:FLUSH WITH COPIOUS AM
OUNTS OF WATER. CALL MD . INGEST:CALL MD IMMEDIATELY .
Fire Fighting
Extinguishing Media:USE WATER, CARBON DIOXIDE OR DRY CHEMICAL TO
EXTINGUISH FIRES.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
& FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL, PHOSGENE .
Accidental Release
Spill Release Procedures:WHERE EXPOS LEVEL NOT KNOWN, WEAR NIOSH/MSHA
APPRVD, POSITIVE PRESS, SCBA. WHERE EXPOS LEVEL KNOWN, WEAR
NIOSH/MSHA APPRVD RESP SUITABLE FOR EXPOS LEVEL. SWEEP UP SPILLS
AND PLACEIN A WASTE DISPOSAL C ONTAINER. FLUSH AREA WITH WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:FOOD, BEVERAGES, & TOBACCO PRODUCTS
SHOULD NOT BE CARRIED, STORED, OR CONSUMED WHERE THIS MATERIAL IS
IN USE. AVOID SKIN CONTACT.
Other Precautions:STREET CLOTHING SHOULD BE STORED SEPARATELY FROM WORK
CLTHG & PROT EQUIP. WORK CLTHG & SHOES SHOULD NOT BE TAKEN HOME. NO
SMKNG IN AREA OF USE. DO NOT USE IN GEN VICIN OF ARC WELDING, OPEN
FLAMES OR H OT SURFS. HEAT &/OR UV RADIA MAY(ING 13)
Exposure Controls
Respiratory Protection:ALL RESPS MUST BE NIOSH/MSHA APPRVD. WHERE EXPOS
ARE BELOW PEL, NO RESP PROT REQ. WHERE EXPOS EXCEED PEL, USE RESP
FOR MATL & LEVEL OF EXPOS. FULL FACEPIECE RESP WILL PROVIDE
EYE/FACE PROT. CUTTING, G RINDING, OR SANDING OF PARTS (ING 14)
Ventilation:WHERE MATL NOT USED IN CLSD SYS, GOOD ENCLOSURE & LOC EXHST
VENT SHOULD BE PROVIDED TO CNTRL EXPOS WHEN (ING 16)
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:CHEM WORK GOGG/FULL LENGTH FSHLD .
Other Protective Equipment:APRON, WORKPANTS, LONG SLEEVE WORK SKIRT OR
DISPOSABLE COVERALLS. BARRIER CREAMS TO BE USED W/GLOVES. EYE WASH
&(ING 17)
Work Hygienic Practices:IT IS REC THAT SHOWER BE TAKEN AFTER WORKSHIFT.
WORK CLTHG SHOULD BE LAUNDERED BEFORE REUSE. BEFORE EATING, (ING
18)
Supplemental Safety and Health
EFTS OF OVEREXP:2-BUTANONE (MEK) VAP MAY CAUSE CNS DEPRESS &
SLEEPINESS. EYE/SKIN CNTCT W/METHYLENE CHLORIDE MAY PRODUCT MOD
IRRIT. ACUTE INHAL OVEREXP TO METHYLENE CHLORIDE VAP CAN CAUSE CNS
DEPRESS. AN INCR IN LUNG CANCER AT 2000 PPM & LIVER CANCER AT 4000
PPM WERE REPORTED IN MICE EXPOSED FOR 2 YEARS, BUT (ING 4)
Chemical Properties
Spec Gravity:1.2
Solubility in Water:NEGLIGIBLE
Appearance and Odor:GREEN, SLIGHTLY TACKY FILM; NO ODOR
Percent Volatiles by Volume:NEG
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, AMINES OR BASIC MATERIALS.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:THERMAL DECOMPOSITION OR COMBUSTION
MAY PRODUCE CO, CO*2, AMMONIA, AND/OR NO*X. HCL, PHOSGENE .
Conditions to Avoid Polymerization:POLYMERIZATION MAY OCCUR SLOWLY AT
ROOM TEMPERATURE. STORE AT OR BELOW 0 F TO PROLONG SHELF LIFE.
Disposal
Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH APPLICABLE
LOCAL, STATE, AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.