BNBWW - 052-611 (1383W15-P003)
- MSDS: BNBWW
- Manufacturer: CENTRY INDUSTRIES INC
- Product Name: 052-611 (1383W15-P003)
- National Stock Number: 6135-01-309-5765
Product Identification
Product ID:052-611 (1383W15-P003)
MSDS Date:07/15/1987
FSC:6135
NIIN:01-309-5765
MSDS Number: BNBWW
Responsible Party
PLANO, TX 75086-1918
US
Emergency Phone: 214-424-1900 OR 312-981-4820
Info Phone: 214-424-1900
Cage: 0EYR5
Contractor
Telephone: 214-424-1900
Cage: 0EYR5
Ingredients
LITHIUM METAL
CAS: 7439-93-2
RTECS: OJ5540000
THIONYL CHLORIDE
CAS: 7719-09-7
RTECS: XM5150000
OSHA PEL C 1 PPM
ACGIH TLV: C 1 PPM; 9192
ALUMINUM CHLORIDE, ANHYDROUS
CAS: 7446-70-0
RTECS: BD0525000
LITHIUM CHLORIDE
CAS: 7447-41-8
RTECS: OJ5950000
Hazards
LD50 LC50 Mixture:LC50 INHAL RAT 500 PPM/1HR.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:VAPORS VERY IRRITATING TO SKIN, EYES
AND MUCOUS MEMBRANES. OVEREXPOSURE CAN CAUSE SYMPTOMS OF
NONFIBROTIC LUNG INJURY.
Effects of Overexposure:EYE AND MUCOUS MEMBRANE IRRITATION.
Medical Cond Aggravated by Exposure:ASTHMA, OTHER RESPIRATORY
DISORDERS, SKIN ALLERGIES, ECZEMA.
First Aid
First Aid:EYE: FLUSH WITH RUNNING WATER FOR AT LEAST 15 MINUTES. HOLD
EYELIDS APART. SEEK IMMEDIATE MEDICAL TREATMENT. SKIN: RINSE WITH
LARGE AMOUNTS OF RUNNING WATER. IF BURNS DEVELOP, SEEK MEDICAL
TREATMENT. INHALATION: REMOVE TO FRESH AIR. IF BREATHING IS
DIFFICULT, ADMINISTER OXYGEN AND SEEK MEDICAL TREATMENT. INGESTION:
N/R.
Fire Fighting
Flash Point:NONE
Extinguishing Media:DRY LITHIUM CHLORIDE, GRAPHITE POWDER, PYRENE G-1,
LITH-X
Fire Fighting Procedures:COVER WITH DRY LITHIUM CHLORIDE OR LITH-X
POWDER. DO NOT USE WATER, MOIST SAND, CARBON DIOXIDE OR SODA-ACID
EXTINGUISHER. WEAR SCBA.
Unusual Fire/Explosion Hazard:DO NOT SHORT CIRCUIT, RECHARGE,
OVERDISCHARGE, PUNCTURE, CRUSH OR EXPOSE TO TEMPERATURES ABOVE
150C.
Accidental Release
Spill Release Procedures:DO NOT BREATHE VAPORS OR TOUCH LIQUID WITH
BARE HANDS.
Neutralizing Agent:SODA LIME
Handling
Handling and Storage Precautions:DO NOT SHORT CIRCUIT, RECHARGE,
OVERDISCHARGE, PUNCTURE, CRUSH OR EXPOSE TO TEMPERATURES ABOVE 150
DEG C ( 302F)
Other Precautions:DO NOT STORE BATTERIES IN HIGH HUMIDITY ENVIRONMENTS
FOR LONG PERIODS.
Exposure Controls
Respiratory Protection:NIOSH APPROVED ACID GAS FILTER MASK.
Ventilation:LOCAL EXHAUST RECOMMENDED
Protective Gloves:BUTYL RUBBER GLOVES
Eye Protection:CHEMICAL WORKER SAFETY GLASSES
Other Protective Equipment:CHEMICAL APRON
Supplemental Safety and Health
PHYSICAL CHARACTERISTICS ARE FOR THIONYL CHLORIDE.
Chemical Properties
HCC:F8
Boiling Pt:B.P. Text:171F,77C
Melt/Freeze Pt:M.P/F.P Text:-157F,-105C
Decomp Temp:Decomp Text:302F,150C
Vapor Pres:92
Vapor Density:4.1
Spec Gravity:1.63
Solubility in Water:DECOMPOSES
Appearance and Odor:LITHIUM BATTERY. THIONYL CHLORIDE IS COLORLESS TO
PALE YELLOW; SHARP ODOR.
Percent Volatiles by Volume:0
Stability
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:TEMPERATURES IN EXCESS OF 150C. HIGH
HUMIDITY FOR EXTENDED PERIODS OF TIME.
Hazardous Decomposition Products:SULFUR DIOXIDE, HYDROGEN CHLORIDE
Disposal
Waste Disposal Methods:NEUTRALIZE SPILL WITH SODA LIME, SEAL LEAKING
BATTERY AND SODA LIME IN PLASTIC BAG AND DISPOSE OF AS HAZARDOUS
WASTE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,