BNCLD - RECHARGEABLE BATTERIES

  • MSDS: BNCLD
  • Manufacturer: POWER SONIC CORP
  • Product Name: RECHARGEABLE BATTERIES
  • National Stock Number: 6140-01-174-7249
Product Identification

Product ID:RECHARGEABLE BATTERIES
MSDS Date:01/14/1990
FSC:6140
NIIN:01-174-7249
MSDS Number: BNCLD

Responsible Party
POWER-SONIC CORP
3106 SPRING ST
REDWOOD CITY, CA 94063-3929
US

Emergency Phone: 415-364-5001/FAX 415-366-3662

Info Phone: 415-364-5001/FAX 415-366-3662

Cage: 56309

Contractor
PRECISION CABLE MFG CO INC
1448 ROCKWALL, TX 75087-1448 US

Telephone: 972-771-1233

Cage: 54840

Ingredients

SULFURIC ACID (SARA III)

CAS: 7664-93-9

RTECS: WS5600000

Fraction By Weight: 17% %

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


LEAD (SARA III)

CAS: 7439-92-1

RTECS: OF7525000

Fraction By Weight: 60% %

OSHA PEL 0.05 MG/M3;1910.1025

ACGIH TLV: 0.15 MG/M3;DUST 9192

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


LEAD PEROXIDE

CAS: 1309-60-0

RTECS: OG0700000

Fraction By Weight: 20% %


NON HAZARDOUS INGREDIENT

Fraction By Weight: BALANCE

Hazards

LD50 LC50 Mixture:NOT SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES?SKIN: AVOID CONTACT WITH
ELECTROLYTE FROM SPILLED OR BROKEN BATTERY. ELECTROLYTE IS SULFURIC
ACID - CORROSIVE. BATTERY UNIT IS CONSIDERED NON-SPILLABLE AND
CONTAINS ELECTROLYTE IN A NON- CONDUCTI VE POLYSTYRENE CASING WHICH
SHOULD NOT PRESENT UNDUE HEALTH OR CONTACT HAZARDS UNLESS CASING
LEAKS OR IS BREACHED.
Explanation of Carcinogenicity:PRODUCT CONTAINS NO INGREDIENTS
CURRENTLY CLASSIFIED AS CARCINOGENIC BY NTP, IARC OR OSHA.
Effects of Overexposure:BURNING OR IRRITAION OF EYES/SKIN IF
ELECTROLYTE ESCAPES AND IS CONTACTED.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYE: IMMEDIATELY FLUSH WITH PLENTY OF WATER FOR 15 MINUTES.
GET MEDICAL ATTENTION. SKIN: WASH WITH SOAP AND WATER. INHALATION:
REMOVE TO FRESH AIR. INGESTED: DRINK WATER OR MILK OF MAGNESIA AND
GET IM MEDIATE MEDICAL ATTENTION.

Fire Fighting

Flash Point:NONFLAMMABLE
Lower Limits:NONFLAMMABLE
Upper Limits:NONFLAMMABLE
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM OR DRY CHEMICAL
AS APPROPRIATE FOR SURROUNDINGS
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA
AND FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE
WATER SPRAY TO COOL NEARBY FIRE-EXPOSED CONTAINERS
Unusual Fire/Explosion Hazard:KEEP AWAY FROM OPEN FLAME AND SPARKS.
IMPROPER CHARGING MAAAY RESULT IN THE BUILD UP OF EXPLOSIVE GASES .

Accidental Release

Spill Release Procedures:MOP OR WIPE UP SPILLED ELECTROLYTE CAREFULLY.
AVOID SKIN CONTACT.
Neutralizing Agent:SODIUM BICARBONATE.

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY AREA. PROTECT
BATTERY FROM PHYSICAL DAMAGE. DO NOT INCINERATE.
Other Precautions:NO SPECIAL PRECAUTIONS UNLESS BATTERY IS BROKEN OR IS
LEAKING.

Exposure Controls

Respiratory Protection:IF VENTILATION DOES NOT MAINTAIN INHALATION
EXOSURES BELOW PEL (TLV), USE NIOSH/MSHA APPROVED RESPIRATOR AS PER
CURRENT 29 CFR 1910.134, INSTRUCTIONS/WARNINGS AND NIOSH RESPIRATOR
SELECTION.
Ventilation:MECHANICAL (GENERAL) VENTILATION IS USUALLY ADEQUATE.
Protective Gloves:RUBBER GLOVES
Eye Protection:SAFETY GLASSES/CHEMICAL SPLASH GOGGLES
Other Protective Equipment:SAFETY SHOWER AND EMERGENCY EYEWASH STATION.
RUBBER APRON.
Work Hygienic Practices:WASH WITH SOAP AND WATER AFTER HANDLING PRODUCT
AND BEFORE EATING DRINKING OR SMOKING.
Supplemental Safety and Health
MATERIAL IS A NON-SPILLABLE BATTERY WITH 17% SULFURIC ACID ELECTROLYTE.

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:NOT GIVEN
Melt/Freeze Pt:M.P/F.P Text:NOT GIVEN
Vapor Pres:NOT GIVEN
Vapor Density:NOT GIVEN
Spec Gravity:NOT GIVEN
Evaporation Rate & Reference:NOT GIVEN
Solubility in Water:NOT GIVEN
Appearance and Odor:RECTANGULAR SQUARE IN SHAPE, ORANGE IN COLOR, NO
ODOR

Stability

Stability Indicator/Materials to Avoid:YES
SOLVENTS MAY DISOLVE CASE MATERIAL.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:SEVERE OVERCHARGING AND OVERHEATING
MAY CAUSE HYDROGEN, OXYGEN, AND SULFUR OXIDE FUMES.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL APPLICABLE
FEDERAL, STATE AND LOCAL REGULATIONS. SEND TO BATTERY RECYCLER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.