BQLRW - TECHNIQUE BASE COAT, 14140-3-4
- MSDS: BQLRW
- Manufacturer: S C JOHNSON WAX
- Product Name: TECHNIQUE BASE COAT, 14140-3-4
- National Stock Number: 6850-00N036091
Product Identification
Product ID:TECHNIQUE BASE COAT, 14140-3-4
MSDS Date:01/23/1992
FSC:6850
NIIN:00N036091
MSDS Number: BQLRW
Responsible Party
RACINE, WI 53403-5011
US
Emergency Phone: 800-228-5635
Info Phone: 414-631-2777;414-631-2488
Preparer: TERRY A. MEYERS
Cage: GO109
Contractor
Telephone: 800-725-6737
Cage: 32204
Ingredients
STYRENE/ACRYLIC POLYMERS
Fraction By Weight: 10-20%
1); (TRIBUTOXYETHYL
CAS: 78-51-3
RTECS: KJ9800000
Fraction By Weight: 1-3%
ETHANOL, 2-(2-ETHOXYETHOXY)-; (GLYCOL ETHER)
CAS: 111-90-0
RTECS: KK8750000
Fraction By Weight: 3-6%
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 70-80%
ZINC OXIDE
CAS: 1314-13-2
RTECS: ZH4810000
Fraction By Weight: 0.2-0.6%
OSHA PEL 15MG/M3 TDUST/5 FUME
ACGIH TLV: 10MG/M3 TDUST; 9293
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:PROLONGED OR REPEATED CONTACT OF
UNDILUTED PRODUCT WITH SKIN MAY CAUSE MINOR IRRITATION. NIOSH
STUDIES INDICATE 2-(2-ETHOXYETHOXY) ETHANOL HAS CAUSED REPRODUCTIVE
DISORDERS IN LABORATORY ANIMALS (RATS OR MICE) AND MAY HAVE
POTENTIAL FOR CAUSING SIMILAR DISORDERS IN HUMANS .
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE KNOWN.
First Aid
First Aid:EYES: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. IF IRRITATION
PERSISTS, SEEK MEDICAL AID. SKIN: WASH SKIN WITH PLENTY OF WATER.
IF IRRITATION PERSISTS, SEEK MEDICAL AID. INHALATION: REMOVE FROM
EXPOSU RE. SUPPORT BREATHING (GIVE ARTIFICIAL RESPIRATION/OXYGEN) .
INGESTION: CALL MD IMMEDIATELY .
Fire Fighting
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL, WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . NORMAL FIRE FIGHTING PROCEDURES MAY BE USED.
Unusual Fire/Explosion Hazard:NO SPECIAL HAZARDS KNOWN.
Accidental Release
Spill Release Procedures:CONTAINS AMMONIA AND ZINC. DO NOT LET SPILLED
OR LEAKING MATERIAL ENTER WATERCOURSES. MAY BE TOXIC TO AQUATIC
LIFE. ABSORB WITH OIL-DRI OR SIMILAR INERT MATERIAL. SWEEP OR
SCRAPE UP AND CONTAINERIZE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN A COOL, DRY PLACE WITH
ADEQUATE VENTILATION. KEEP FROM FREEZING.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:NO SPECIAL REQUIREMENTS UNDER NORMAL USE
CONDITIONS. WEAR NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:GENERAL ROOM VENTILATION ADEQUATE.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:USE GOOD PERSONAL HYGIENE PRACTICES.
Supplemental Safety and Health
VAPOR PRESSURE: SAME AS WATER. VAPOR DENSITY: SAME AS WATER. PH:
8.4-9.2.
Chemical Properties
Boiling Pt:B.P. Text:>200F,>93C
Melt/Freeze Pt:M.P/F.P Text:32F,0C
Vapor Pres:SUPP DATA
Vapor Density:SUPP DATA
Spec Gravity:1.05 (H*2O=1)
pH:SUPDAT
Solubility in Water:COMPLETE
Appearance and Odor:MILKY-WHITE, OPAQUE LIQUID WITH MILD ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:WHEN EXPOSED TO FIRE, PRODUCES NORMAL
PRODUCTS OF COMBUSTION.
Disposal
Waste Disposal Methods:NO SPECIAL METH. OBSERVE ALL APPLIC FEDERAL,
STATE AND LOCAL REGS REGARDING DISPOSAL OF NON-HAZARDOUS MATS.
WASTE FROM NORMAL PRODUCT USE MAY BE SEWERED TO PUBLIC-OWNED
TREATMENT WORKS (POTW) IN COMPL IANCE W/APPLIC FED, ST & LOC
PRETREATMENT REQS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.