BRBDS - 713030 CALIBRATION GAS MIXTURE
- MSDS: BRBDS
- Manufacturer: PPG BIOMEDICAL SYSTEMS INC
- Product Name: 713030 CALIBRATION GAS MIXTURE
- National Stock Number: 6830-00F027817
Product Identification
Product ID:713030 CALIBRATION GAS MIXTURE
MSDS Date:02/08/1990
FSC:6830
NIIN:00F027817
MSDS Number: BRBDS
Responsible Party
LENEXA, KS 66219
US
Emergency Phone: 304-843-1300
Info Phone: 800-321-3251, 913-894-7500
Cage: 0ASU5
Contractor
Telephone: 800-321-3251, 913-894-7500
Cage: 0ASU5
Ingredients
FORANE, ISOFLURANE, 1-CHLORO-2,2,2-TRIFLUOROETHYL
CAS: 26675-46-7
RTECS: KN6799000
Fraction By Weight: 1%
OSHA PEL ASPHYXIANT
FLUOTHANE, HALOTHANE
CAS: 151-67-7
RTECS: KH6550000
Fraction By Weight: 1%
OSHA PEL ASPHYXIANT
ACGIH TLV: 50 PPM
CARBON DIOXIDE
CAS: 124-38-9
RTECS: FF6400000
Fraction By Weight: 5%
OSHA PEL 5000 PPM
ACGIH TLV: 5000PPM/30000STEL;93
OXYGEN (GAS)
CAS: 7782-44-7
RTECS: RS2060000
Fraction By Weight: 30%
NITROUS OXIDE, NITROGEN OXIDE, NITROGEN MONOXIDE
CAS: 10024-97-2
RTECS: QX1350000
Fraction By Weight: 62%
OSHA PEL ASPHYXIANT
ACGIH TLV: 1050 MG/CUM
ENFLURANE, ANESTHETIC COMPOUND, ANESTHETIC GAS
CAS: 13838-16-9
RTECS: KN6800000
Fraction By Weight: 1%
OSHA PEL ASPHYXIANT
ACGIH TLV: 75 PPM
Hazards
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: CENTRAL NERVOUS SYSTEM
DEPRESSION, ANESTHESIA, HEADACHE, DIZZINESS, FATIGUE, HEPATIC
NECROSIS, CARDIAC ARREST, HYPOTENSION, RESPIRATORY ARREST, CARDIAC
ARRHYTHMIAS, HYPERPYREXIA, SHIVERING , NAUSEA, & VOMITING.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALATION: NERVOUS SYSTEM, LIVER & KIDNEY
DISEASE, SPONTANEOUS ABORTIONS, FETAL ABNORMALITIES, & MENSTRUAL
IRREGULARITIES.
First Aid
First Aid:INHALATION: REMOVE TO FRESH AIR. IF BREATHING IS DIFFICULT,
ADMINISTER OXYGEN. IF BREATHING STOPS, ADMINISTER ARTIFICIAL
RESPIRATION. EYES: IMMEDIATELY FLUSH W/LARGE AMOUNTS OF TEPID
POTABLE WATER. SK IN: REMOVE CONTAMINATED CLOTHING. OBTAIN MEDICAL
ATTENTION IN ALL CASES.
Fire Fighting
Flash Point:NONE
Extinguishing Media:NON-FLAMMABLE. USE EXTINGUISHING MEDIA APPROPRIATE
FOR MATERIAL FUELING FIRE.
Fire Fighting Procedures:COOL FIRE EXPOSED CONTAINERS W/WATER SPRAY TO
AVOID EXCESSIVE PRESSURE. WEAR SELF-CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:PRESSURE CAN BUILD UP IN CONTAINERS DUE
TO HEAT. CYLINDER MAY EXPLODE IF PRESSURE RELIEF DEVICES SHOULD
FAIL TO RELIEVE PRESSURE.
Accidental Release
Spill Release Procedures:EVACUATE ALL PERSONNEL. VENTILATE UNTIL ALL
TRACES ARE ELIMINATED. SHOULD THE LEAK BE THE USER'S EQUIPMENT,
PURGE & CHECK USING INERT GAS PRIOR TO ATTEMPTING REPAIRS.
Handling
Handling and Storage Precautions:CYLINDERS SHOULD NOT BE DROPPED,
DRAGGED, SLID OR ROLLED. KEEP PROPERLY SECURED & IN UPRIGHT
POSITION TO PREVENT CYLINDERS FROM BEING KNOCKED OVER.
Other Precautions:FULL & EMPTY CYLINDERS SHOULD BE KEPT SEGREGATED.
MATERIAL CAN BE STORED OUTSIDE. TEMPERATURE SHOULD BE KEPT BELOW
125F. USE ONLY IN WELL VENTILATED AREAS. DON'T INHALE GAS FROM
CYLINDER. CYLINDERS MU ST NOT BE RECHARGED.
Exposure Controls
Respiratory Protection:USE SELF-CONTAINED BREATHING APPARATUS IF
VENTILATION IS NOT ADEQUATE TO KEEP BELOW TLV LEVELS
Ventilation:LOCAL MECHANICAL TO KEEP CONCENTRATIONS BELOW RECOMMENDED
LIMITS
Eye Protection:SAFETY GLASSES OR GOGGLES W/SIDE SHIELDS
Other Protective Equipment:SAFETY SHOES
Supplemental Safety and Health
Chemical Properties
Vapor Pres:760
Vapor Density:>1
Appearance and Odor:COLORLESS GAS W/SWEET PUNGENT ODOR
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
STRONG REDUCING AGENTS, COMBUSTIBLES, OIL & GREASE
Hazardous Decomposition Products:ORGANIC CHLORINE & FLUORINE PRODUCTS,
HYDROGEN FLUORIDE & HYDROGEN CHLORIDE
Disposal
Waste Disposal Methods:SLOWLY VENT TO ATMOSHPHERE IN OPEN AIR OR
THROUGH APPROPRIATE GAS SCAVENGING SYSTEM. THIS CYLINDER IS NOT
INTENDED FOR REFILL, DISPOSE OF IN ACCORDANCE W/FEDERAL, STATE &
LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,