BSBCM - DRY CHARGE BATTERY

  • MSDS: BSBCM
  • Manufacturer: EXIDE CORP
  • Product Name: DRY CHARGE BATTERY
  • National Stock Number: 6140-00-185-6714
Product Identification

Product ID:DRY CHARGE BATTERY
MSDS Date:09/01/1993
FSC:6140
NIIN:00-185-6714
MSDS Number: BSBCM

Responsible Party
EXIDE CORP
645 PENN ST
READING, PA 19612-4205
US

Emergency Phone: 215-378-0798

Info Phone: 215-378-0798

Cage: 20038

Contractor
JOINT AND CLUTCH SVC INC. DIV OF MIDWAY
UNKNOW READING, PA 19601 US

Telephone: 215-378-0527/800-424-9300(CHEMTREC)

Cage: 5P322

Ingredients

LEAD (SARA III)

CAS: 7439-92-1

RTECS: OF7525000

Fraction By Weight: 53% %

OSHA PEL 0.05 MG/M3;1910.1025

ACGIH TLV: 0.15 MG/M3;DUST 9293

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


ANTIMONY (SARA III)

CAS: 7440-36-0

RTECS: CC4025000

Fraction By Weight: 0.2% %

OSHA PEL 0.5 MG/M3

ACGIH TLV: 0.5 MG SB/M3; 9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ARSENIC (SARA III)

CAS: 7440-38-2

RTECS: CG0525000

Fraction By Weight: 0.003% %

OSHA PEL 0.5 MG/M3 (AS)

ACGIH TLV: 0.01,A1 MG/M3; 9394

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


CALCIUM, METAL

CAS: 7440-70-2

RTECS: EV8040000

Fraction By Weight: 0.02% %


TIN

CAS: 7440-31-5

RTECS: XP7320000

Fraction By Weight: 0.05% %

OSHA PEL 2 MG/M3

ACGIH TLV: 2 MG/M3; 9293


POLYPROPYLENE RUBBER

CAS: 9003-07-0

Fraction By Weight: 5-6% %

Hazards

LD50 LC50 Mixture:150 UG/M3 ACGIH TLV FOR LEAD
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:HAZARDOUS EXPOSURE TO LEAD COMPOUNDS
CAN OCCUR ONLY WHEN PRODUCT IS HEATED, OXIDIZED OR OTHERWISE
PROCESSED OR DAMAGED TO CREATE DUST, VAPOR OR FUME. INHALATION OF
LEAD DUST MAY CAUSE RESPIRATORY TRAC T IRRITATION. INGESTION MAY
CUASE GASTROINTESTINAL DISTURBANCES. MAY CAUSE EYE IRRITATION.
Explanation of Carcinogenicity:CONTAINS INORGANIC ARSENIC [7440-38-2]
AND LEAD WHICH ARE LISTED BY NTP AND IARC AND REGULATED BY OSHA AS
CARCINOGENS.
Effects of Overexposure:ACUTE: HEADACHE, FATIGUE, ABDOMINAL PAIN, LOSS
OF APPETITE, MUSCULAR ACHES AND WEAKNESS, SLEEP DISTURBANCES AND
IRRITABILITY. CHRONIC: ANEMIA, NEUROPATHY--PARTICULARLY OF THE
MOTOR NERVES WITH WRIST D ROP, KIDNEY DAMAGE, REPRODUCTIVE CHANGES
IN BOTH MALES AND FEMALES.
Medical Cond Aggravated by Exposure:LEAD AND ITS COMPOUNDS CAN
AGGRAVATE SOME FORMS OF KIDNEY, LIVER AND NEUROLOGIC DISEASES.

First Aid

First Aid:INHALATION: REMOVE FROM EXPOSURE. GARGLE, WASH NOSE AND LIPS.
CONSULT PHYSICIAN. INGESTION: CONSULT PHYSICIAN IMMEDIATELY. SKIN:
WASH IMMEDIATELY WITH SOAP AND WATER. EYES: FLUSH IMMEDIATELY WITH
LARG E AMOUNTS OF WATER FOR 15 MINUTES. CONSULT PHYSICIAN.

Fire Fighting

Flash Point:NONFLAMMABLE
Lower Limits:4.1 % (H2)
Upper Limits:74.2% (H2)
Extinguishing Media:CARBON DIOXIDE, FOAM, DRY CHEMICAL
Fire Fighting Procedures:WEAR FULL BODY PROTECTIVE CLOTHING AND SELF-
CONTAINED BREATHING APPARATUS WITH POSITIVE PRESSURE AND FULL
FACEPIECE.
Unusual Fire/Explosion Hazard:HIGHLY FLAMMABLE HYDROGEN GAS (H2) IS
GENERATED DURING CHARGING AND OPERATION. TO AVOID RISK, KEEP
IGNITION SOURCES AWAY FROM BATTERIES.

Accidental Release

Spill Release Procedures:LEAD DUST SHOULD BE VACUUMED OR WET-SWEPT. USE
CONTROLS WHICH MINIMIZ
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE BATTERIES IN COOL, DRY,
WELL-VENTILATTED AREAS WITH IMPERVIOUS SURFACES AND ADEQUATE
CONTAINMENT IN THE EVENT OF SPILLS.
Other Precautions:BATTERIES SHOULD BE STORED UNDER ROOF FOR PROTECTION
AGAINST ADVERSE WEATHER CONDITIONS. SEPARATE FROM INCOMPATIBLE
MATERIALS. STORE AND HANDLE ONLY IN AREAS WITH ADEQUATE WATER
SUPPLY AND SPILL CONTR OL. AVOID DAMAGE TO CONTAINERS.

Exposure Controls

Respiratory Protection:NONE REQUIRED UNDER NORMAL CONDITIONS.
Ventilation:STORE AND HANDLE IN WELL-VENTILATED AREA.
Protective Gloves:RUBBER OR PLASTIC ACID-RESISTANT
Eye Protection:CHEMICAL GOGGLES/FACE SHIELD
Other Protective Equipment:COVERALLS OR FULL-BODY COVERING DURING USE.
WHEN FILLING BATTERIES USE ACID RESISTANT APRON.
Work Hygienic Practices:HANDLE BATTERIES CAUTIOUSLY TO AVOID SPILLS.
MAKE CERTAIN VENT CAPS ARE ON SECURELY. AVOID CONTACT WITH INTERNAL
PARTS.
Supplemental Safety and Health
DO NOT ALLOW METALLIC MATERIALS TO SIMULTANEOUSLY CONTACT NEGATIVE AND
POSITIVE TERMINALS OF CELLS AND BATTERIES. FOLLOW MANUFACTURER'S
INSTRUCTIONS FOR INSTALLATION AND SERVICE.

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:>2516F,>138
Melt/Freeze Pt:M.P/F.P Text:NOT GIVEN
Vapor Pres:NOT GIVEN
Vapor Density:NOT GIVEN
Spec Gravity:9.6 TO 11.3
Evaporation Rate & Reference:NIL
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BLUSIH GRAY METAL; NO APPARENT ODOR
Percent Volatiles by Volume:0 %

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS, BASES, HALIDES, HALOGENATES, POTASSIUM NITRATE,
PERMANGANATE, PEROXIDES, REDUCING AGENTS, NASCENT HYROGEN
Stability Condition to Avoid:PROLONGED OVERCHARGE, SOURCES OF IGNITION
Hazardous Decomposition Products:TOXIC METAL FUME/VAPOR/DUST; CONTACT
WITH STRONG ACID IN PRESENCE OF NASCENT HYDROGEN MAY GENERATE
ARSINE GAS.

Disposal

Waste Disposal Methods:SEND SPENT BATTERIES TO SECONDARY LEAD SMELTER
FOR RECYCLING. PLACE NEUTRALIZED SLURRY INTO SEALED CONTAINERS AND
DISPOSE OF AS HAZARDOUS WASTE AS APPLICABLE. WASTE SHOULD BE
MANAGED IN ACCORDANCE WIT H APPROVED LOCAL, STATE AND FEDERAL
REQUIREMENTS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.