BSBGC - TECHNESCAN SULFUR COLLOID, SYRINGE A

  • MSDS: BSBGC
  • Manufacturer: MALLINCKRODT
  • Product Name: TECHNESCAN SULFUR COLLOID, SYRINGE A
  • National Stock Number: 6810-00N040064
Product Identification

Product ID:TECHNESCAN SULFUR COLLOID, SYRINGE A
MSDS Date:01/01/1992
FSC:6810
NIIN:00N040064
Kit Part:Y
MSDS Number: BSBGC

Responsible Party
MALLINCKRODT
2703 WAGNER PL
MARYLAND HEIGHTS, MO 63043
US

Emergency Phone: 314-344-3800

Info Phone: 314-344-3800

Cage: ZA916

Contractor
MALLINCKRODT MEDICAL, INC
M MARYLAND HEIGHTS, MO 63043 US

Telephone: 314-770-7800

Cage: ZA916

Ingredients

HYDROCHLORIC ACID (0.148N)

CAS: 7647-01-0

RTECS: MW4025000

Fraction By Weight: 100%

OSHA PEL 5 PPM STEL, C

ACGIH TLV: 5 PPM STEL, C

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


APPROPRIATE REGS OF GOVT AGENCY AUTHORIZED TO

RTECS: 9999999ZZ


212F,100C(RECONSTITUTED)

RTECS: 9999999ZZ


32F, 0C(RECONSTITUTED)

RTECS: 9999999ZZ


EYES & CLOTHING.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:THE HAZARDOUS INGREDIENTS FOUND IN
PRODUCT ARE SKIN & EYE IRRITANTS, BUT DUE TO THE SMALL QTY PRESENT
IN EACH CONTAINERS, NO ADVERSE HEALTH EFFECTS ARE EXPECTED TO OCCUR
FROM EXPOSURE. ACUTE: INHAL/IN GEST/SKIN/EYE: NOT EXPECTED TO BE A
HEALTH HAZARD. CHRONIC: NOT EXPECTED TO BE A CHRONIC HEALTH HAZARD.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NO INFORMATION FOUND.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR. SUPPORT BRTHG (GIVE O*2/ARTF
RESP) . INGEST: CALL MD IMMED . SKIN: WASH EXPOSED AREA WITH SOAP
AND WATER. GET MEDICAL ADVICE IF IRRITATION DEVELOPS. EYE: WASH T
HORO WITH RUNNING WATER FOR AT LEAST 15MINUTES. GET MEDICAL ADVICE
IF IRRITATION DEVELOPS.

Fire Fighting

Extinguishing Media:USE ANY MEANS SUITABLE FOR EXTINGUISHING
SURROUNDING FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NOT CONSIDERED TO BE A FIRE AND EXPLOSION
HAZARD.

Accidental Release

Spill Release Procedures:COLLECT NON-RADIOACTIVE SPILLS & DISPOSE OF
MATL IN AN APPRVD FACILITY AS NON-HAZ WASTE. FOR TECHNESCAN SULFUR
COLLOID PREPARTED W/SODIUM PERTECHNETATE TC-99M: IF ANY LOSS/REL OF
RADIOACTIVE CONTENTS OCCURS, NOTIFY YOUR RADIA SFTY DEPT (SUPP
DATA)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DRUG SHOULD BE STORED @ 15C-30C,BOTH
PRIOR TO & FOLLOW RECONSTITUTION W/SODIUM PERTECHNETATE TC-99M &
DISCARDED AFTER 6 HRS FROM TIME OF PREPARATION.
Other Precautions:AFTER PREPARATION, HNDLG TIME SHOULD BE KEPT TO A
MIN, & APPROP SHIELDING SHOULD BE USED. HNDLG DEVICES SUCH AS
SYRINGE SHIELDS & TONGS SHOULD BE USED. STOR & DISP OF PROD SHOULD
BE CONTROLLED IN A MA NNER THAT IS IN COMPLIANCE (SUPP DATA)

Exposure Controls

Respiratory Protection:NOT EXPECTED TO REQUIRE PERSONAL RESPIRATOR
USAGE. USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE
OF CONCERN .
Ventilation:NOT EXPECTED TO REQUIRED ANY SPECIAL VENTILATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APRV CHEM WORK GOGG .
Other Protective Equipment:CLEAN BODY-COVERING CLOTHING.
Work Hygienic Practices:AS PART OF GOOD LAB & PERS HYG & SFTY PROC,
AVOID ALL UNNEC EXPOS TO CHEM SUBS & ENSURE PROMPT REMOVAL FROM
SKIN,(ING 7)
Supplemental Safety and Health
APPEAR/ODOR: CNTNG 1.5 ML CLEAR LIQ. ODORLESS. SPILL PROC: &
MALLINCKRODT @ (314)344-3800. ALL CLEANUP OPERATIONS SHOULD BE
PERFORMED ACCDG TO STD OPERATING PROC (SOPS) ESTABLISHED FOR YOUR
FACILITY. RADIOACTIVE WASTE SHOULD BE DISPOSED OFACCDG TO SOPS
ESTABLISHED BY YOUR RADIA SFTY OFFICER. OTHER PREC: W/ (ING 5)

Chemical Properties

Boiling Pt:B.P. Text:SEE ING 3
Melt/Freeze Pt:M.P/F.P Text:SEE ING 4
Solubility in Water:SOLUBLE
Appearance and Odor:GLASS VIAL (10 ML) CNTNG SM CRYSTALS; SYRINGE A &
SYRINGE B, EACH (SUPP DATA)

Stability

Stability Indicator/Materials to Avoid:YES
NO INFORMATION FOUND.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:SODIUM HYDROXIDE: MAY EMIT TOXIC FUMES
OF SODIUM OXIDE WHEN HEATED TO DECOMPOSITION.

Disposal

Waste Disposal Methods:ENSURE COMPLIANCE WITH LOCAL, STATE AND FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.