BSBST - PENN-RAY ADHESIVE

  • MSDS: BSBST
  • Manufacturer: CAMIE CAMPBELL INC
  • Product Name: PENN-RAY ADHESIVE
  • National Stock Number: 8040-00N040924
Product Identification

Product ID:PENN-RAY ADHESIVE
MSDS Date:10/01/1985
FSC:8040
NIIN:00N040924
MSDS Number: BSBST

Responsible Party
CAMIE-CAMPBELL INC
9225 WATSON INDUSTRIAL PARK
ST LOUIS, MO 63126
US

Emergency Phone: 314-968-3222

Info Phone: 314-968-3222

Cage: 31868

Contractor
CAMIE CAMPBELL
ST. LOUIS, MO 63126 US

Telephone: 314-968-3222

Cage: 31868

Ingredients

BENZIN; (COMMERCIAL HEXANE)

CAS: 8030-30-6

RTECS: DE3030000

Fraction By Weight: 27%


METHANE, DICHLORO-; (METHYLENE CHLORIDE)

CAS: 75-09-2

RTECS: PA8050000

Fraction By Weight: 40%

OSHA PEL 500 PPM;1000 PPM, C

ACGIH TLV: 50 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


PROPANE

CAS: 74-98-6

RTECS: TX2275000

Fraction By Weight: 20%

OSHA PEL 1000 PPM

ACGIH TLV: SIMPLE ASPHYXIANT

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INHALATION OF VAPORS MAY PRODUCE
DIZZINESS IN HIGH CONCENTRATION, UNCONSCIOUSNESS AND EVEN DEATH.
MAY IRRITATE EYES, CAUSING REDNESS AND BLURRED VISION. ABSORBED
THROUGH SKIN, CAUSING DEFATTING. CHLOR OCARBON MATERIALS HAVE
PRODUCED SENSITIZATION OF MYOCARDIUM TO EPINEPHRINE IN LABORATORY
ANIMALS AND (EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE: GRP 2B (IARC VOL
SUP7, P194, '87), ANTIC TO BE CARCIN (NTP 6TH ANN RPT, '91).
Effects of Overexposure:HEALTH HAZARDS: COULD HAVE SIMILAR EFFECT IN
HUMANS. ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE CONTRAINDICATED
EXCEPT FOR LIFE-SUSTAINING USES IN HUMANS ACUTELY OR CHRONICALLY
EXPOSED TO CHLOROCARBONS .
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYE: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. SEE PHYSICIAN
IF IRRITATION PERSISTS. SKIN: FLUSH WITH WATER FOR 15 MINUTES. SEE
PHYSICIAN IF IRRITATION PERSISTS. INHALATION: REMOVE TO FRESH AIR,
ADMIN ISTER OXYGEN. IF BREATHING HAS STOPPED,GIVE ARTIFICIAL
RESPIRATION AND CALL PHYSICIAN. INGESTION: DO NOT INDUCE VOMITING.
CALL PHYSICIAN.

Fire Fighting

Flash Point Method:COC
Flash Point:0F,-18C
Lower Limits:2.2%
Upper Limits:9.5%
Extinguishing Media:FOAM, CARBON DIOXIDE OR DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT . KEEP SURROUNDING AREAS COOL WITH
WATER.
Unusual Fire/Explosion Hazard:CHARACTERISTIC OF AEROSOLS-KEEP AWAY FROM
HEAT, SPARKS OR OPEN FLAME. THERMAL DECOMPOSITION PRODUCT MAY
INCLUDE HCL AND PHOSGENE .

Accidental Release

Spill Release Procedures:VENTILATE AREA WELL. REMOVE ADHESIVE BY
SCRAPING, THEN SCRUB WITH SOLVENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP AWAY FROM SPARKS, OPEN FLAME,
HEAT AND OXIDIZING AGENTS. USE ADEQUATE VENTILATION.
Other Precautions:DO NOT PUNCTURE, INCINERATE OR STORE ABOVE 120F OR IN
DIRECT SUNLIGHT.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED CHEMICAL VAPOR RESPIRATOR
MAY BE WORN.
Ventilation:LOCAL EXHAUST. MECHANICAL (GENERAL) SUFFICIENT.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:ANSI APRV CHEM WORK GOGG .
Other Protective Equipment:APRON OR LAB COAT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPECIFIC GRAVITY: 0.75-1.32 (H*2O=1).

Chemical Properties

Boiling Pt:B.P. Text:>103F,>39C
Vapor Density:HVR/AIR
Spec Gravity:SUPP DATA
Evaporation Rate & Reference:6.9 (BUTYL ACETATE=1)
Solubility in Water:NIL
Appearance and Odor:CREAM WHITE (SHARP ODOR CHARACTERISTIC).
Percent Volatiles by Volume:87

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZERS.
Stability Condition to Avoid:HIGH TEMPERATURES AND PRESSURES.
Hazardous Decomposition Products:CARBON MONOXIDE, PHOSGENE, HCL.

Disposal

Waste Disposal Methods:DISPOSE ACCORDING TO LOCAL, STATE AND FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.