BSBTG - STATIC ALL SPRAY, ST10S-5

  • MSDS: BSBTG
  • Manufacturer: CAIG LABORATORIES INC
  • Product Name: STATIC ALL SPRAY, ST10S-5
  • National Stock Number: 6850-00N042935
Product Identification

Product ID:STATIC ALL SPRAY, ST10S-5
MSDS Date:04/01/1992
FSC:6850
NIIN:00N042935
MSDS Number: BSBTG

Responsible Party
CAIG LABORATORIES INC
16744 W BERNARDO DR
RANCHO BERNARDO, CA 92127-1904
US

Emergency Phone: 619-451-1799;800-356-3129

Info Phone: 800-441-3637

Cage: 55403

Contractor
CAIG LABORATORIES INC
POWAY, CA 92064 US

Telephone: 858-486-8388

Cage: 55403

Ingredients

2.1

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: 68%

OSHA PEL 400 PPM;500 STEL

ACGIH TLV: 400 PPM;500 STEL


ETHANE, 1,1-DIFLUORO-; (DIFLUOROETHANE)

CAS: 75-37-6

RTECS: KI1410000

Fraction By Weight: 30%

OSHA PEL N/K

ACGIH TLV: N/K


WATER

CAS: 7732-18-5

RTECS: ZC0110000

OSHA PEL N/K

ACGIH TLV: N/K


AMMONIA

CAS: 7664-41-7

RTECS: BO0875000

OSHA PEL 35 PPM STEL

ACGIH TLV: 25 PPM;35 PPM STEL

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


SURFACTANT

OSHA PEL N/K

ACGIH TLV: N/K


INTERVENTION IS INDICATED AS CMPD IS NOT

RTECS: 9999999ZZ


OF EXCESSIVE QTY MAY CAUSE IRRIT OF DIGESTIVE TRACT

RTECS: 9999999ZZ


SOAP & WATER. IF IRRIT PERSIST SEEK MED

RTECS: 9999999ZZ


SWALLOWED, & SYMPS DEVELOP, SEEK MED ATTN. NOTE TO

RTECS: 9999999ZZ


RESIDUE W/ANY STANDARD SOAP OR DETERGENT

RTECS: 9999999ZZ


HANDS AFTER USE.

RTECS: 9999999ZZ


MUST BE USED.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: ING 1: INHAL: HAS A LOW DEGREE
OF TOX, BRTHG HIGH CONC OF VAPS/MISTS MAY CAUSE IRRIT OF NOSE &
THROAT & SIGNS OF NERV SYS DEPRESS (E.G. HDCH, DROW, DIZZ). RESP
SYMPS ASSOC W/PRE- EXISTING LUNG DISORDERS (E.G., ASTHMA-LIKE
CNDTNS) MAY BE AGGRAVATED BY EXPOS. ING 2: VAP IS HVR/AIR & CAN
CAUSE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: ASPHY BY REDUCING OXYGEN AVAIL FOR
BRTHG. BRTHG HIGH CONC OF VAP MAY CAUSE LT-HEAD, DIZZ, SHORT OF
BRTH, & MAY LEAD TO NARCOS, CARDIAC IRREG, UNCON/DEATH. EYE: IS AN
IRRITANT. DIRECT CONT W/ LIQ/EXPOS TO VAPS/MISTS MAY CAUSE STING,
TEAR, RED & SWELL. SKIN: MAY CAUSE MILD IRRIT. INGEST: NO SPEC (ING
6)
Medical Cond Aggravated by Exposure:RESP SYMPS ASSOC W/PRE-EXISTING
LUNG DISORDERS (E.G., ASTHMA-LIKE CONDITIONS).

First Aid

First Aid:INHAL: MOVE AWAY FROM SOURCE OF EXPOS & INTO FRESH AIR. IF
SYMPS PERSIST, SEEK IMMED MED ATTN. IF NOT BRTHG, BEGIN ARTF RESP.
IF BRTHG DFCLTYS DEVELOP, OXYGEN SHOULD BE ADMINISTERED, SEEK MED
ATTN. EY E: IF IRRIT/RED DEVELOPS, FLUSH W/CLEANWATER & SEEK MED
ATTN. FOR DIRECT CONT, HOLD LIDS APART & FLUSH AFFECTED EYE(S)
W/CLEAN WATER FOR @ LST 15 MIN. SKIN: CLEANSE AFFECTED AREA(S)
W/MILD (ING 8)

Fire Fighting

Flash Point Method:TCC
Flash Point:53.6F,12.0C
Lower Limits:2%
Upper Limits:12%
Extinguishing Media:DRY CHEM, CARBON DIOXIDE, HALON, POLAR/ALCOHOL
FOAM/ WATER SPRAY IS RECOM. WATER MAY BE INEFFECTIVE.
Fire Fighting Procedures:NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP. MOVE
UNDMGD CONTRS FROM FIRE AREA IF IT CAN BE DONE W/OUT RISK. AVOID
SPREADING BURNING LIQ W/WATER (SUPP DATA)
Unusual Fire/Explosion Hazard:MATL IS FLAMM & MAY BE IGNITED BY HEAT,
SPARKS, FLAME/OTHER SOURCES OF IGNIT (E.G. STATIC ELEC, PILOT
LIGHTS, MECH/ ELEC EQUIP). VAPS MAY TRAVEL (SUPP DATA)

Accidental Release

Spill Release Procedures:FLAMM.KEEP AWAY FROM ALL SOURCES OF IGNIT &
HOT SURF. SPILLED MATL MAY BE ABSORBED INTO ANY ABSORB MATL. WEAR
APPROP PROT EQUIP INCL RESP PROT AS CNDTNS WARRANT. VENT AREA
UNTILL ODOR IS GONE. AFTER I PA HAS BEEN REMOVED BY VENT, CLEAN UP
OILY(ING 10)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT EXPOSE ANY AEROSOL CAN TO
SUNLIGHT/ TEMP ABOVE 120F TO PVNT POSS BURSTING. ALL AEROSOL
CAUTIONS APPLY-USE IN WELL VENTD AREAS.
Other Precautions:USE & STORE IN COOL, DRY, WELL VENTD AREAS AWAY FROM
HEAT, HOT SURF & ALL SOURCES OF IGNIT. PROTECT CONTRS FROM PHYSICAL
DAM. INDOOR STOR SHOULD MEET OSHA STD & APPROP CODES. AS W/ANY CHEM
PREPARATION - USE ONLY AS DIRECTED & WASH (ING 11)

Exposure Controls

Respiratory Protection:NOT NECESSARY UNLESS USED IN AN UNVENTILATED
AREA OR IN HIGH CONCENTRATIONS. USE NIOSH/MSHA APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:KEEP EXPOS BELOW LIM. KEEP WINDOWS OPEN. LOC EXHST: WHEN
USED REPEATLY IN QTY. ELEC SYS SAFE FOR SUCH LOCATIONS (ING 12)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPR CHEMICAL SAFETY GOGGLES
Other Protective Equipment:NOT NECESSARY WITH ADEQUATE VENTILATION.
Work Hygienic Practices:AVOID BREATHING VAPORS AND CONTACT WITH SKIN/
EYES, USE ADEQUATE VENTILATION.
Supplemental Safety and Health
SPEC GRAV: 0.786@60F(H2O=1). FIRE FIGHT PROC: USED FOR COOLING
PURPOSES. EXPLO HAZ: CONSIDERABLE DIST TO A SOURCE OF IGNIT WHERE
THERE MAY IGNITE, FLASHBACK/EXPLODE. VAP/AIR EXPLO HAZ INDOORS/OUT
DOOR S/IN SEWERS. VAPS HVR/AIR & MAY ACCUM IN LOW AREAS. IF CONTR
IS NOT PROPERLY COOLED, IT MAY EXPLODE IN HEAT OF FIRE.

Chemical Properties

HCC:V3
Boiling Pt:B.P. Text:180F,82C
Vapor Pres:37
Vapor Density:ING 1
Spec Gravity:SUPP DATA
Evaporation Rate & Reference:1.7(BUTYL ACETATE=1)
Solubility in Water:IPA(100%)
Appearance and Odor:COLOR, CLEAR, SLIGHT ALCOHOL ODOR

Stability

Stability Indicator/Materials to Avoid:YES
ANHYDRIDES, ISOCYANATES, ACETALDEHYDE, CHLORINE, ETHYLENE OXIDE,
HYDROGEN PEROXIDE, ALUMINUM & ORGANOMETALLIC CONTAM.
Stability Condition to Avoid:AVOID OPEN FLAMES AND HIGH TEMPERATURES.
Hazardous Decomposition Products:COMBUSTION MAY YIELD CARBON MONOXIDE
&/OR CARBON DIOXIDE. DO NOT BREATHE SMOKE/FUMES. WEAR APPROP PROT
EQUIP.
Conditions to Avoid Polymerization:WILL NOT OCCUR, HOWEVER, AVOID OPEN
FLAMES AND HIGH TEMPS.

Disposal

Waste Disposal Methods:COMPLY WITH FEDERAL, STATE AND LOCAL LAWS AND
REGULATIONS. EPA HAZARDOUS WASTE #'S F001 & F002 MAY APPLY.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.