BSBWB - KRYLON 9101 GLASS CLEANER
- MSDS: BSBWB
- Manufacturer: BORDEN
- Product Name: KRYLON 9101 GLASS CLEANER
- National Stock Number: 7930-00N044035
Product Identification
Product ID:KRYLON 9101 GLASS CLEANER
MSDS Date:02/04/1987
FSC:7930
NIIN:00N044035
MSDS Number: BSBWB
Responsible Party
COLUMBUS, OH 43215
US
Emergency Phone: 614-431-6600
Info Phone: 614-431-6680
Cage: 9P972
Contractor
Telephone: 614-431-6600/800-848-9400
Cage: 9P972
Ingredients
ISOPROPYL ALCOHOL
CAS: 67-63-0
RTECS: NT8050000
Fraction By Weight: 8.6%
OSHA PEL 400 PPM;500 STEL
ACGIH TLV: 400 PPM;500 STEL
PROPANE, 2-METHYL-; (ISOBUTANE)
CAS: 75-28-5
RTECS: TZ4300000
Fraction By Weight: 5%
OSHA PEL N/K
ACGIH TLV: N/K
W/PROT EQUIP & PRUDENT WORK PRACTICES. MFR RECOM
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: SKIN ABSORP: NO HAZS KNOWN.
INGEST: NOT EXPECTED TO BE HARMFUL UNDER NORM CNDTNS OF USE. INHAL:
MAY BE HARMFUL. LIQ/VAP CAN CAUSE IRRIT OF NOSE, THROAT & LUNGS.
SKIN/EYES: CAUSES IRRIT. ING 1: CAN CAUSE CNS DEPRESS. SIGNS &
SYMPS MAY INCL HDCH, DIZZ, NAUS, VOMIT, UNCON & EVEN ASPHY.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INGEST: IF ACCIDENTLY SWALLOWED, DILUTE BY DRINKING LG QTY OF
WATER. IMMED CONT POIS CTL CTR/HOSP EMER ROOM FOR ANY OTHER ADDNL
TRTMT DIREC. INHAL: REMOVE TO FRESH AIR. IF NOT BRTHG, GIVE ARTF
RESP, P REF MOUTH-TO-MOUTH. IF BRTHG IS DFCLT, GIVE OXYGEN. CALL A
PHYS. SKIN: FLUSH W/WATER. IF IRRIT PERSISTS, CALL A PHYS. EYE:
IMMED FLUSH W/PLENTY OF WATER FOR @ LST 15 MIN. EYELIDS SHOULD BE
(SUPP DATA)
Fire Fighting
Extinguishing Media:IN CASE OF FIRE, WATER SHOULD BE USED TO KEEP FIRE-
EXPOSED CONTAINERS COOL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:CONTENTS UNDER PRESS. EXPOS TO HIGH TEMP
MAY CAUSE BURST. AVOID RADIA, STOVES, DIRECT SUNLIGHT/OTHER HEAT
SOURCE. DO NOT PUNCTURE/INCINERATE CONTAINER.
Accidental Release
Spill Release Procedures:SOAK UP WITH ABSORBENT MATERIAL AND REMOVE TO
A CHEMICAL DISPOSAL AREA. PREVENT ENTRY INTO NATURAL BODIES OF
WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT STORE AT TEMPERATURES OVER
120F. AVOID PRLNGD/RPTD CONT W/EYES/SKIN/CLTHG. AVOID BRTHG
VAP/MIST. USE W/ADEQ VENT.
Other Precautions:HANDLE I/A/W GOOD INDUST HYGIENE & SFTY PRACTICES.
THESE PRACTICES INCL AVOIDING UNNEC EXPOS & REMOVAL OF MATL FROM
EYES, SKIN & CLTHG.
Exposure Controls
Respiratory Protection:WHERE AIR CONTAM CAN EXCEED ACCEPTABLE CRITERIA,
USE NIOSH/MSHA APPRVD RESP PROT EQUIP. RESP SHOULD BE SELECTED
BASED ON FORM & CONC OF CONTAM IN AIR I/A/W OSHA 29 CFR
1910.134/OTHER APPLIC STD/ GUIDE LINES.
Ventilation:IF AIRBORNE CONTAM ARE GENERATED WHEN MATL IS HEATED/HNDLD,
SUFFICIENT VENT IN VOL & PATTERN SHOULD BE (SUPP DATA)
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPR CHEMICAL SAFETY GOGGLES
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
% VOLAT: 100 BY WT. FIRST AID PROC: HELD APART DURING IRRIGATION TO
INSURE WATER CONTACT W/ENTIRE SURFACE OF EYES AND LIDS. CALL A
PHYSICIAN. VENT: PROVIDED TO KEEP AIR CONTAM CONC LEVELS BELOW
ACCEPT ABLE CRITERIA. THE FOLLOWING MAY BE USED: LOC EXHST, ENCLSD
SYS, PROCESS ISOLATION, REMOTE CTL IN COMBINATION (ING 3)
Chemical Properties
Vapor Pres:35PSIG
Vapor Density:HVR/AIR
Spec Gravity:LTR/WATER
Evaporation Rate & Reference:SLOWER THAN BUTYL ACETATE
Solubility in Water:SOLUBLE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:SUPDAT
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:OXIDES OF CARBON.
Disposal
Waste Disposal Methods:INCINERATION WILL CAUSE CONTAINER TO BURST
VIOLENTLY. DISPOSE OF I/A/W LOCAL, STATE, AND FEDERAL REQUIREMENTS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.