BSCFM - MS-300C HARDENER COMPONENT

Product Identification

Product ID:MS-300C HARDENER COMPONENT
MSDS Date:05/08/1991
FSC:8010
NIIN:00N044682
MSDS Number: BSCFM

Responsible Party
AMERICAN SAFETY TECHNOLOGIES INC
565 EAGLE ROCK AVE
ROSELAND, NJ 07068
US

Emergency Phone: 201-403-2600;800-424-9300(CHEMTREC)

Info Phone: 201-403-2600

Cage: AMSAT

Contractor
AMERICAN SAFETY TECHNOLOGIES INC.
ROSELAND, NJ 07068 US

Telephone: 800-424-9300

Cage: AMSAT

Ingredients

1,2-ETHANEDIAMINE,

CAS: 112-57-2

RTECS: KH8585000

Fraction By Weight: 4%

OSHA PEL N/K

ACGIH TLV: N/K


POLYAMIDE RESIN

CAS: 68410-23-1

OSHA PEL N/K

ACGIH TLV: N/K


BUTYL ALCOHOL

CAS: 71-36-3

RTECS: EO1400000

Fraction By Weight: 20%

OSHA PEL 50 PPM, S, C

ACGIH TLV: 50 PPM, S, C

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYES: CAUSES SEVERE
IRRITATION/BURNS. MAY CAUSE PERMANENT VISUAL IMPAIRMENT. SKIN:
CAUSES SEVERE IRRITATION/BURNS. MAY BE ABSORBED THRU SKIN IN
HARMFUL AMTS. INHAL: MAY CAUSE UPPER RESPIRATORY TRACT IRRITATION.
INGEST: MAY CAUSE BURNS OF MOUTH & THROAT. CONTAINS MATERIAL THAT
MAY BE SLIGHTLY TOX.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:IRRITATION, SENSITIZATION AND DERMATITIS.
Medical Cond Aggravated by Exposure:ALLERGY, ECZEMA AND OTHER SKIN
CONDITIONS.

First Aid

First Aid:EYE: FLUSH WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15
MINUTES. GET MEDICAL ATTENTION. SKIN: REMOVE CONTAMD CLTHG. WASH
CONTACT AREA WITH MILD SOAP AND WATER. INHAL: REMOVE TO FRESH AIR.
IF SYMPTOMS P ERSIST CONSULT A PHYSICIAN. INGEST: DO NOT INDUCE
VOMITING. IF CONSCIOUS, GIVE LARGE QTY OF WATER TO DILUTE. GET
MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:PMCC
Flash Point:>100F,>38C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, CHEMICAL FOAM/WATER.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP.
REMOVE ALL IGNIT SOURCES.
Unusual Fire/Explosion Hazard:DECOMPOSITION AND COMBUSTION PRODUCTS MAY
BE TOXIC.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. DIKE SPILL.
ABSORB WITH INERT MATERIAL AND COLLECT FOR DISPOSAL. FLUSH
CONTAMINATED AREA WITH DILUTE (5%) ACETIC ACID AND COLLECT RINSATE
FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID ALL PERSONAL CONTACT. DO NOT
EXCEED 110F/43C IN STORAGE AREAS. GROUND AND BOND METAL CONTAINERS
FOR LIQUID TRANSFER TO AVOID STATIC SPARKS.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR WITH ORGANIC
VAPOR CARTRIDGE IF REQUIRED.
Ventilation:EXPLO-PROOF MECH VENT & LOC EXHST ARE RECOMM. MECH EXHST IS
NOT RECOM AS SOLE MEANS OF CONTROLLING EMPLOYEE EXPOSURE.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:CHEMICAL SPLASH-PROOF GOGGLES.
Other Protective Equipment:IN OPERATIONS WHERE CONT MAY OCCUR
COVERALLS, APRON & IMPERVIOUS FOOT COVERING ARE RECOM. SFTY SHOWER
& (SUPP DATA)
Work Hygienic Practices:IMMED REMOVE AND THOROUGHLY LAUNDER
CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
OTHER PROT EQUIP: EYE WASH FACILITY SHOULD BE AVAILABLE TO EMPLOYEES.

Chemical Properties

HCC:F4
Spec Gravity:0.96
Solubility in Water:PARTIALLY SOLUBLE
Appearance and Odor:AMBER LIQUID, SOLVENT ODOR

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:EXCESSIVE HEAT.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
ALDEHYDES AND OXIDES OF NITROGEN.

Disposal

Waste Disposal Methods:DISPOSE OF I/A/W FEDERAL, STATE AND LOCAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.