BSCNQ - ANHYDROUS AMMONIA 82-0-0, C7664417

  • MSDS: BSCNQ
  • Manufacturer: CHEVRON
  • Product Name: ANHYDROUS AMMONIA 82-0-0, C7664417
  • National Stock Number: 6810-00N045154
Product Identification

Product ID:ANHYDROUS AMMONIA 82-0-0, C7664417
MSDS Date:01/12/1991
FSC:6810
NIIN:00N045154
MSDS Number: BSCNQ

Responsible Party
CHEVRON
RICHMOND, CA 94804
US

Emergency Phone: 800-457-2022; 415-233-3737

Info Phone: 800-457-2022; 415-233-3737

Cage: 0AHD1

Contractor
CHEVRON ENVIRONMENTAL HEALTH CENTER INC
4054 RICHMOND, CA 94804 US

Telephone: 800-582-3835

Cage: 0AHD1

Ingredients

IRRIT, SWELLING OF EYELIDS & LIPS, DRY RED MOUTH &

RTECS: 9999999ZZ


DFCLTY BRTHG, SIGNS & SYMP OF LUNG CONGESTION &

RTECS: 9999999ZZ


RESP. CALL MD. SEE MD IMMED. PROMPT ACTION

RTECS: 9999999ZZ


MED ADVICE. DO NOT MAKE PERSON VOMIT UNLESS DIRECTED

RTECS: 9999999ZZ


PERSON & PROD CNTNR TO NEAREST MED EMER TREATEMENT

RTECS: 9999999ZZ


AMMONIA GAS CAN BE CONTROLLED USING WATER FOG.

RTECS: 9999999ZZ


WILL CAUSE LIQ TO BOIL & GENERATE MORE GAS.

RTECS: 9999999ZZ


AMMONIA; (CHEVRON ANHYDROUS AMMONIA 82-0-0) (SARA III)

CAS: 7664-41-7

RTECS: BO0875000

Fraction By Weight: 100%

OSHA PEL 35 PPM STEL

ACGIH TLV: 25 PPM; 35 STEL

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


CONC > 5000PPM MAY CAUSE SUDDEN DEATH FROM

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES:SEV IRRIT & COULD CAUSE PERM DMG
& BLINDNESS. SYMP INCL PAIN, TEARS, SWELLING, REDNESS & BLURRED
VISION. AMMONIA GAS VERY IRRIT. SKIN:CORR. COULD CAUSE PERM INJURY
(INCL SCARRING). EXTENSIVE & PR LNG CNTCT COULD CAUSE SIGNIFICANT
INJURY TO UNDERLYING TISS & DEATH. SYMP INCL PAIN/FEELING OF HEAT,
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:DISCOLORATION, SWELLING & BLISTERING.
AMMONIA GAS MAY CAUSE IRRIT, ESP IF SKIN IS MOIST. LIQ CAN CAUSE
DMG, RSLTING FROM COMBINED FREEZING & CORR ACTION ON SKIN.
INGEST:MAY CAUSE SEV IRRIT/UL CERATION OF DIGEST TRACT WHICH MAY
RSLTIN NAUS, VOMIT, DIARR & IN SEV CASES, COLLAPSE, SHOCK & DEATH.
INHAL: (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES:FLUSH IMMED W/FRESH WATER FOR @ LEAST 15 MIN WHILE
HOLDING EYELIDS OPEN. REMOVE CONTACT LENSES IF WORN. SEE MD FOR
FURTHER TREATMENT AS SOON AS POSS. SKIN:REMOVE CONTAMD CLTHG. WASH
SKIN THORO W/ SOAP & WATER. SEE MD IMMED. DISCARD CONTAMD
NON-WATERPROOF SHOES & BOOTS. WASH CONTAMD CLTHG. CHEM HAZ REQS
IMMED FULL 15 MIN WASHDOWN. INHAL:MOVE TO FRESH AIR. IF BRTHG
STOPPED, APPLY ARTF (ING 5)

Fire Fighting

Lower Limits:16%
Upper Limits:27%
Extinguishing Media:SHUT OFF SUPPLY OF GAS.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:COMBUSTION MAY PRODUCE TOXIC COMPOUNDS OF
NITROGEN OXIDE.

Accidental Release

Spill Release Procedures:MATL TOX TO AQ ORG & SHOULD BE KEPT OUT OF
SEWAGE & DRAINAGE SYS & ALL BODIES OF WATER. IF RELS INTO WORK
AREA, EVAC IMMED. PERSONS ENTERING CONTAMD AREA TO CORRECT PROB &
DETERM IF IT IS SAFE TO RESU ME NORM ACTIVITIES MUST WEAR PROT
EQUIP. (ING 8)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:REFER TO PRODUCT LABEL OR
MANUFACTURERS' TECHNICAL BULLETINS FOR THE PROPER USE AND HANDLING
OF THIS MATERIAL.
Other Precautions:BEFORE ENTRY INTO CONFINED SPACES THAT MAY HAVE
CONTAINED HAZARDOUS MATERIAL, DETERMINE CONCENTRATIONS & TAKE
APPROPRIATE MEASURES FOR PERSONAL PROTECTION. MATERIAL PRESENTS A
HAZARD THAT MAY REQUIRE PERSONAL PROTECTIVE EQUIPMENT FOR ENTRY.

Exposure Controls

Respiratory Protection:WEAR NIOSH/MSHA APPROVED RESPIRATORY PROTECTION
WHEN WORKING WITH THIS MATERIAL. A NIOSH/MSHA APPROVED
AIR-SUPPLYING RESPIRATOR IS RECOMMENDED.
Ventilation:VENT MUST BE DEMONSTRATED TO BE ADEQ TO KEEP AIRBORNE CONC
OF MATL < RECOM EXPOSURE STANDARDS PRIOR TO USING THIS MATL.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:CHEMICAL GOGGLES & FACE SHIELD.
Other Protective Equipment:EMER EYE WASH & DELUGE SHOWER . WEAR
IMPERVIOUS PROT CLTHG INCL GLOVES, APRON, OVERSHOES & COMPLETE
FACIAL PROT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MATLS TO AVOID:W/SILVER & MERCURY. EFTS OF OVEREXP:EXTREMELY IRRIT.
SYMPS INCL NASAL DISCHARGE, SORE THROAT, COUGH, BRONCH, PULM EDEMA
& DFCLTY BRTHG. AMMONIA GAS VERY IRRIT TO MUC MEMB OF NOSE, THROA T
& LUNGS & CAN CAUSE PULM EDEMA. NOTICEABLE @ 100PPM. CONC > 400PPM
MAY DESTROY MUC SURF UPON PRLNG CNTCT. (ING 2)

Chemical Properties

HCC:G5
Boiling Pt:B.P. Text:-27F,-33C
Vapor Pres:SEE ING 1
Vapor Density:0.6
Spec Gravity:0.618 @ 15.6C
Solubility in Water:SOLUBLE
Appearance and Odor:COLORLESS GAS (WATER-WHITE LIQUID WHILE UNDER
PRESS) W/EXTREMELY PUNGENT ODOR.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
MAY REACT W/STRONG ACIDS/STRONG OXIDIZING AGENTS SUCH AS CHLORATES,
NITRATES, PEROXIDES, ETC. FORMS EXPLO CMPDS (SUPDAT)
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NO DATA AVAILABLE.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL,
STATE AND LOCAL REGULATIONS . ALLOW SPILLED AMMONIA TO EVAPORATE,
AS IT IS TOO VOLATILE TO ABSORB. KEEP UNPROTECTED PERSONNEL AWAY
FROM AREA UNTIL IT IS FREE OF AMMONIA.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.