BSCPR - NICKEL SELENIDE

  • MSDS: BSCPR
  • Manufacturer: CERAC INC
  • Product Name: NICKEL SELENIDE
  • National Stock Number: 9630-00N045356
Product Identification

Product ID:NICKEL SELENIDE
MSDS Date:08/14/1986
FSC:9630
NIIN:00N045356
MSDS Number: BSCPR

Responsible Party
CERAC INC
MILWAUKEE, WI 53201
US

Emergency Phone: 414-289-9800;800-424-9300(CHEMTREC)

Info Phone: 414-289-9800

Cage: FO994

Contractor
CERAC, INCORPORATED
1178 MILWAUKEE, WI 53233 US

Telephone: 414-289-9800

Cage: 67027

Ingredients

0.2 MG/M3 (SE); 1 MG/M3 (NI).

CAS: 1314-05-2

RTECS: QR8926000

Fraction By Weight: 100%

OSHA PEL SEE INGREDIENT NAME

ACGIH TLV: SEE INGREDIENT NAME

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INHAL: INHAL OF SELENIUM CMPNDS CAN
CAUSE IRRIT, METALLIC TASTE & GARLIC ODOR TO THE BREATH. SEVERE
OVEREXP CAN CAUSE SHORTNESS OF BREATH, BRONCHOSPASMS, FEVER,
CHILLS. NICKEL IS AN IRRITANT AND CAN C AUSE PNEUMONITIS IF
EXPOSURE IS SEVERE.CERTAIN INDIVIDUALS MAY DEVELOP RESP SENSIT TO
NICKEL. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NICKEL CMPNDS:IARC MONOGRAPHS ON EVAL OF
CARCIN RISK OF CHEMS TO MAN:GRP 2B. NTP 6TH ANNUAL REPORT ON (SUPP
DATA)
Effects of Overexposure:HLTH HAZ: SKIN/EYE: MILD IRRIT TO SKIN, EYE,
AND MUC MEMBS. (DUST) RPTD CNTCT W/NICKEL CAN CAUSE A FORM OF
DERMATITIS (NICKEL ITCH). SELENIUM CAN ALSO CAUSE DERMATITIS AFTER
REPEATED CONTACT. OTHER: N ICKEL HAS LOW SYSTEMIC TOX BUT
SELENIUMMAY CAUSE PALLOR, WEAKNESS, GI TRACT DISTURBANCES AND
NERVOUSNESS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST: INDUCE VOMITING. INHAL: REMOVE TO FRESH AIR. SKIN:
FLUSH WITH SOAP AND WATER. EYE: FLUSH WITH PLENTY OF WATER FOR AT
LEAST 15 MIN.

Fire Fighting

Extinguishing Media:AGENTS FOR METAL FIRES (LIKE G-1 POWDER, MET-L-X,
OR TEC).
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:SWEEP OR SCOOP UP AND REMOVE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CONTAINER CLOSED.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED AIR PURIFYING
RESPIRATOR, IF DUST OR FUMES ARE BEING GENERATED.
Ventilation:LOCAL EXHAUST: TO MAINTAIN EXPOSURE BELOW TLV. MECHANICAL
(GENERAL): NOT RECOMMENDED.
Protective Gloves:NEOPRENE.
Eye Protection:SAFETY GLASSES.
Other Protective Equipment:NORMAL LABORATORY WEAR.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
CARCIN COMMENTS: CARCINS: 1991: ANTICIPATED TO BE CARCINOGENIC.

Chemical Properties

HCC:T6
Vapor Density:8.46
Solubility in Water:INSOLUBLE
Appearance and Odor:GREY CRYSTALLINE PIECES, NO ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NI AND SE FUME UPON HEATING TO
DECOMPOSITION.

Disposal

Waste Disposal Methods:DISPOSE OF IN APPROVED HAZARDOUS WASTE LANDFILL.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.