BSDFJ - BATTERY, STORAGE
- MSDS: BSDFJ
- Manufacturer: MARATHON POWER TECHNOLOGIES
- Product Name: BATTERY, STORAGE
- National Stock Number: 6140-00-431-6805
Product Identification
Product ID:BATTERY, STORAGE
MSDS Date:12/09/1992
FSC:6140
NIIN:00-431-6805
MSDS Number: BSDFJ
Responsible Party
WACO, TX 75714-8233
US
Emergency Phone: 800-424-9300 (CHEMTREC)
Info Phone: 817-776-0650
Preparer: DSCR-VBA
Cage: 74025
Contractor
Telephone: 254-741-5405
Cage: 74025
Ingredients
CADMIUM (SARA III)
CAS: 7440-43-9
RTECS: EU9800000
OSHA PEL 0.1MG/M3FUME;0.2DUST
ACGIH TLV: 0.05 MG/M3 DUST;9192
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
CADMIUM HYDROXIDE.
CAS: 21041-95-2
OSHA PEL 0.2 MG CD/M3
ACGIH TLV: 0.05 MG CD/M3
NICKEL (SARA III)
CAS: 7440-02-0
RTECS: QR5950000
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3; 9192
NICKEL HYDROXIDE (SARA III)
CAS: 12054-48-7
RTECS: QR7040000
OSHA PEL 0.1 MG NI/M3
ACGIH TLV: 0.1 MG NI/M3; 9192
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
POTASSIUM HYDROXIDE (SARA III)
CAS: 1310-58-3
RTECS: TT2100000
OSHA PEL C, 2 MG/M3
ACGIH TLV: C 2 MG/M3; 9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:IF SEAL BROKEN, CONTACT WITH CONTENT
MAY CAUSE IRRITATION OF THE MUCOUS MEMBRANES, DRYNESS OF MOUTH AND
THROAT, HEADACHE, NAUSEA AND DIZZINESS. INHALATION MAY BE HARMFUL
TO THE LUNG TISSUES.. CHRONIC: LOW LEVEL EXPOSURE IN AIR MAY CAUSE
IRREVERSIBLE LUNG INJURY, KIDNEY DISEASE AND OTHER ADVERSE EFFECTS.
INGESTION MAY CAUSE NAUSEA, VOMITING, DIARRHEA.
Explanation of Carcinogenicity:CONTAINS C [7440-43-9] WHICH IS
LISTED BY NTP AND IARC AND REGULATED BY OSHA AS A CARCINOGEN.
Effects of Overexposure:IF SEAL BROKEN CONTACT WITH INGREDIENTS MAY
CAUSE SKIN SENSITIVITY AND ALLERGIC SKIN RASHES. INHALATION OF
AIRBORNE DUST OR MISTS MAY CAUSE DAMAGE TO UPPER RESP TRACT AND
EVEN TO LUNG TISSUES WHICH CO ULD PRODUCE CHEMICAL PNEUMONIA. THIS
MATERIAL IS DESTRUCTIVE TO SKIN TISSUES, EYE TISSUES AND MOUTH,
THROAT, STOMACH TISSUES.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYE: FLUSH WITH WATER 15 MIN, HOLD LIDS OPEN. SKIN: WASH WITH
SOAP & WATER. REMOVE CONTAMINATED CLOTHING AND LAUNDER BEFORE
REUSE. INHALATION: REMOVE TO FRESH AIR. RESTORE BREATHING IF
NECESSARY. INGE STION: DO NOT INDUCE VOMITING. GIVE 2 LARGE GLASSES
OF MILK OR WATER AND GET IMMEDIATE MEDICAL CARE. NOTHING BY MOUTH
IF UNCONSCIOUS.
Fire Fighting
Flash Point:NONE
Extinguishing Media:USE EXTINGUISHING MEDIA APPROPRIATE FOR SURROUNDING
FIRE.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD WEAR PROPER PROTECTIVE
EQUIPMENT AND SELF-CONTAINED BREATHING APPARATUS WITH FULL
FACE-PIECE OPERATED IN POSITIVE PRESSURE MODE.
Unusual Fire/Explosion Hazard:CONTACT WITH STRONG OXIDIZERS MAY CAUSE
FIRE OR EXPLOSION. CADMIUM FUMES OR VAPORS ARE TOXIC AND CAN CAUSE
DEATH.
Accidental Release
Spill Release Procedures:BATTERY AND CELL CASES WILL NORMALLY CONTAIN
MATERIALS OF CONCERN. USE INDUSTRIAL ABSORBENT TO COLLECT LIQUID
POTASSIUM HYDROXIDE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:AVOID BREAKING, CRUSHING OR OTHERWISE
DESTROYING THE PHYSICAL INTEGRITY OF THE CELL OR BATTERY.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:RESPIRATOR WILL NOT NORMALLY BE NECESSARY. USE
NIOSH/MSHA APPROVED AIR SUPPLIED RESPIRATOR OR RESPIRATOR FOR
ALKALINE DUST/MIST IF EXPOSURE IS ABOVE THE TLV/PEL.
Ventilation:ADEQUATE LOCAL EXHAUST VENTILATION WHEN HANDLING THE LIQUID
IN THE BATTERY.
Protective Gloves:RUBBER GLOVES.
Eye Protection:SAFETY GLASSES OR SPLASH GOGGLES
Other Protective Equipment:CLOTHING TO MINIMIZE SKIN CONTACT.
Work Hygienic Practices:USE GOOD CHEMICAL HYGIENE PRACTICE. AVOID
UNNECESSARY CONTACT. WASH THOROUGHLY BEFORE EATING OR DRINKING.
Supplemental Safety and Health
THE CONTRACTING TECHNICAL DATA FILE INDICATE THIS BATTERY IS
NICKEL-CADMIUM, SEALED CELL, SIZE C.
Chemical Properties
HCC:Z5
Appearance and Odor:BATTERY, 1.2 VOLTS, ALKALINE. HEIGHT=1.959 IN.
DIAMETER=1.034 IN.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, NITRATES, NITRIC ACID
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
Disposal
Waste Disposal Methods:CELLS AND BATTERIES MAY BE RETURNED AT SENDERS
EXPENSE TO MARATHON POWER TECHNOLOGIES. DISPOSAL SHALL BE BY
APPROVED METHODS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.