BXBDR - SHOOTERS CHOICE BLACK POWDER CLEANING GEL

  • MSDS: BXBDR
  • Manufacturer: VENCO INDUSTRIES INC
  • Product Name: SHOOTERS CHOICE BLACK POWDER CLEANING GEL
  • National Stock Number: 7930-00N058096
Product Identification

Product ID:SHOOTERS CHOICE BLACK POWDER CLEANING GEL
MSDS Date:11/04/1991
FSC:7930
NIIN:00N058096
MSDS Number: BXBDR

Responsible Party
VENCO INDUSTRIES INC
16770 HILLTOP PK PLACE
CHAGRIN FALLS, OH 44022
US

Emergency Phone: 216-543-8808

Info Phone: 216-543-8808

Cage: 0KCW1

Contractor
VENCO INDUSTRIES, INC
CHAGRIN FALLS, OH 44022 US

Telephone: 216-543-8808

Cage: 0KCW1

Ingredients

ETHANOL, 2-BUTOXY-; (ETHANOL, 2-BUTOXY)

CAS: 111-76-2

RTECS: KJ8575000

Fraction By Weight: 5-20%

OSHA PEL 50 PPM

ACGIH TLV: 25 PPM


BENZIN; (NAPTHA (AROMATIC SOLVENT BLEND))

CAS: 8030-30-6

RTECS: DE3030000

Fraction By Weight: 35-50%

OSHA PEL 500 PPM (MFR)

ACGIH TLV: 100 PPM (MFR)


9-OCTADECANOIC ACID (Z)-, AMMONIUM SALT

CAS: 544-60-5

RTECS: RG3700000

Fraction By Weight: 1-15%

OSHA PEL N/K

ACGIH TLV: N/K


NON-HAZARDOUS INGREDIENTS OR <1%

Fraction By Weight: BALANCE

OSHA PEL N/K

ACGIH TLV: N/K


CONTENTS MAY BE HARMFUL/FATAL. AS PREC, EXPOSURE TO

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:HDCH, DIZZ, NAUS FROM INHAL OF VAPS;
SKIN & EYE IRRIT. ASPIR OF MATL INTO LUNGS MAY CAUSE CHEM PNEUM,
WHICH MAY BE FATAL. CHRONIC:"ANIMAL STUDIES CLEARLY DEMONSTRATED
DOSE-RELATED ADVERSE EFTS ON CNS, HEMATOPOIETIC TISS, BLOOD,
KIDNEYS & LIVER, ASSOC W/ADMIN OF ETHYLENE GLYCOL MONO BUTYL ETHER
(EGBE). (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS:(EXTRACTED FROM DHHS (NIOSH)
PUBLICATION NO 90-118) . HLTH STUDIES HAVE SHOWN THAT MANY PETROL
HYDROCARBS & SYNTHETIC LUBRICANTS POSE HUMAN HLTH RISKS WHICH MAY
VARY FROM PERSON TO PER SON. PRLNGD OVEREXPOS TO OTHER COMPONENTS
IN PROD MAY CAUSE TRANSIENT DECREASE IN RED BLOOD CELL COUNT, &
(SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES:FLUSH WITH RUNNING WATER FOR AT LEAST 15 MINUTES,
HOLDING LIDS OPEN TO EXPOSE SURFACE, CONTACT PHYSICIAN. SKIN:REMOVE
CONTAMINATED CLOTHING AND SHOES. WASH WITH MILD SOAP AND WATER,
APPLY SKIN CR EAM FOR IRRITATION. INHAL:REMOVE TO FRESH AIR AT
ONCE. APPLY ARTIFICIAL RESPIRATION IF NECESSARY, CONTACT PHYSICIAN
IMMEDIATELY. INGEST:DO NOT INDUCE VOMITING, CONTACT PHYSICIAN
IMMEDIATELY.

Fire Fighting

Flash Point Method:COC
Flash Point:140F,60C
Lower Limits:0.9%
Upper Limits:10.6%
Extinguishing Media:FOAM, DRY CHEMICAL, CO*2.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT . WATER IS NOT SUITABLE AS AN EXTING MEDIA,
BUT MAY BE USED FOR COOLING NEARBY CONTAINERS.
Unusual Fire/Explosion Hazard:PRESSURE MAY DEVELOP IN CLOSED CONTAINERS
IF OVERHEATED.

Accidental Release

Spill Release Procedures:REMOVE IGNITION SOURCES. DIKE AND TAKE UP WITH
ABSORBENT MATERIAL. ENSURE ADEQUATE VENTILATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CONTAINERS CLOSED WHEN NOT IN
USE. DO NOT STORE OR HANDLE NEAR HEAT, SPARKS, FLAME OR STRONG
OXIDIZERS. ALWAYS MAINTAIN ADEQUATE VENTILATION.
Other Precautions:AVOID BREATHING VAPORS OR MISTS; PROLONGED OR
REPEATED SKIN CONTACT.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED SCBA OR APPROVED
HYDROCARBON VAPOR RESPIRATOR WHENEVER EXPOSURE LEVELS EXCEED
ESTABLISHED STANDARDS.
Ventilation:MAINTAIN LEVEL BELOW STANDARDS. LOCAL EXHAUST:YES. RATE:>60
FPM. MECHANICAL (GENERAL):NO.
Protective Gloves:CHEMICAL RESISTANT.
Eye Protection:ANSI APPROVED SAFETY GLASSES .
Other Protective Equipment:NONE REQUIRED IN NORMAL USE.
Work Hygienic Practices:BASIC GOOD HOUSEKEEPING.
Supplemental Safety and Health
EFTS OF OVEREXP:INCREASED FRAGILITY OF RED BLOOD CELLS. ADDNLY, IN
ANIMAL TERATOLOGY STUDIES W/BUTYL CELLOSOLVE, ADVERSE EFTS WERE
SEEN IN OFFSPRING AT LEVELS THAT WERE NOT MATERNALLY TOX. RPTS HAVE
A SSOC PRLNGD & RPTD OCCUP OVEREXP TO SOLVS W/PERM BRAIN & NERV SYS
DMG. INTENTIONAL MISUSE BY DELIB CONC & INHAL (ING 5)

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
Vapor Pres:<1
Spec Gravity:0.92
Solubility in Water:NIL
Appearance and Odor:AMBER LIQUID, PETROLEUM ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS LIKE CHLORINE OR CONCENTRATED O*2.
Stability Condition to Avoid:HEAT, SPARKS, OPEN FLAME.
Hazardous Decomposition Products:VARIOUS OXIDES OF CARBON.

Disposal

Waste Disposal Methods:COMPLY WITH ALL APPLICABLE LOCAL, STATE AND
FEDERAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.