BXBGJ - MINERAL OIL, LIGHT, 0121, 01224

  • MSDS: BXBGJ
  • Manufacturer: FISHER SCIENTIFIC CHEMICAL
  • Product Name: MINERAL OIL, LIGHT, 0121, 01224
  • National Stock Number: 9150-00N058174
Product Identification

Product ID:MINERAL OIL, LIGHT, 0121, 01224
MSDS Date:05/17/1994
FSC:9150
NIIN:00N058174
MSDS Number: BXBGJ

Responsible Party
FISHER SCIENTIFIC CHEMICAL
1 REAGENT LANE
FAIR LAWN, NJ 07410
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 201-796-7100

Cage: 1B464

Contractor
FISHER SCIENTIFIC CO. CHEMICAL MFG DIV
FAIRLAWN, NJ 07410-2802 US

Telephone: 201-796-7100

Cage: 1B464

Ingredients

MINERAL OIL, WHITE; (MINERAL OIL, LIGHT & HEAVY, C15-50)

CAS: 8042-47-5

RTECS: PY8047000

Fraction By Weight: 100%

OSHA PEL N/K

ACGIH TLV: N/K


STUDIES EXHIBITED OIL IN LUNG MACROPHAGES.

RTECS: 9999999ZZ


VARIOUS SKIN DISORDERS SUCH AS ECZEMATOUS/CONT DERM,

RTECS: 9999999ZZ


OCCASIONALY LIFTING UPPER & LOWER LIDS,

RTECS: 9999999ZZ


TREAT SYMPTOMATICALLY &

RTECS: 9999999ZZ


HEAD LOWER THAN HIPS TO PREVENT ASPIRATION.

RTECS: 9999999ZZ


BASED ON CONTAM LEVELS FOUND IN WORK PLACE, MUST

RTECS: 9999999ZZ


BY NATIONAL INSTITUTE FOR OCCUPATIONAL SFTY & HLTH &

RTECS: 9999999ZZ


50 MG/M3-ANY SUPP-AIR RESP. ANY SCBA. ANY

RTECS: 9999999ZZ


125 MG/M3-ANY SUPP-AIR RESP OPERATED IN

RTECS: 9999999ZZ


EFFICIENCY PARTICULATE FILTER. 250 MG/M3-ANY

RTECS: 9999999ZZ


PARTICULATE FILTER. ANY POWERED AIR-PURIFYING RESP

RTECS: 9999999ZZ


PARTICULATE FILTER. ANY SUPP-AIR RESP THAT HAS

RTECS: 9999999ZZ


MODE. ANY SCBA W/FULL FACEPIECE. ANY SUPP-AIR RESP

RTECS: 9999999ZZ


OPERATED IN PRESS-DEMAND/OTHER POS-PRESS MODE.

RTECS: 9999999ZZ


EFFICIENCY PARTICULATE FILTER. ANY APPROP

RTECS: 9999999ZZ


ANY SCBA THAT HAS FULL

RTECS: 9999999ZZ


MODE. ANY SUPP-AIR RESP THAT HAS FULL FACEPIECE &

RTECS: 9999999ZZ


COMBINATION W/AUXILIARY SCBA OPERATED IN

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: HAZ IS LOW EXCEPT WHEN
MISTED/HEATED WHICH MAY RESULT IN IRRIT. EYES: GEN, OILS OF THIS
TYPE CAUSE NO MORE THAN MIN IRRIT. INGEST: ALTHOUGH MINERAL OILS
GEN ARE OF A LOW ORDER OF TOXICIT Y, THEY MAY CAUSE GI DISTURB SUCH
AS DIARR. ASPIR & SUBSEQUENT PULM INFILTRATION MAY BE POSS.
CHRONIC: (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: INHAL: PRLNG/RPTD EXPOS TO OIL MISTS
HAS CAUSED LIPOID PNEUM, INFLAMM W/W/OUT PNEUM, FIBROSIS &
PARAFFINOMA. OIL GRANULOMAS HAVE BEEN PRODUCED IN ANIMALS EXPOSED
TO AEROSOLS/MISTS OF PARAFFI NIC WHITE OILS FOR PERIODS OF UP TO
TWOYRS AT CONCS OF 100 MG/M3. ANIMALS EXPOSED TO LEVELS OF 5 MG/M3
IN (ING 2)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL: REMOVE FROM EXPOS AREA TO FRESH AIR IMMED. IF BRTHG
HAS STOPPED, PERFORM ARTF RESP. KEEP PERS WARM & AT REST. TREAT
SYMPTOMATICALLY & SUPPORTIVELY. GET MD ATTN IMMED. SKIN: REMOVE
EXCESS OIL W/ CLEAN, DRY CLOTH. WASH THORO W/MILD DETERGENT & SOFT
BRUSH. AVOID USE OF SOLV, PARAFFIN & STRONG DETERGENTS. GET MD ATTN
IF SKIN IRRIT OCCURS. EYES: WASH IMMED W/LGE AMTS OF WATER/NORM
SALINE, (ING 4)

Fire Fighting

Flash Point:>360F,>182C
Extinguishing Media:DRY CHEM, CO*2, WATER SPRAY/REGULAR FOAM. FOR
LARGER FIRES USE WATER SPRAY, FOG/REGULAR FOAM (1993 EMERGENCY (SUP
DAT)
Fire Fighting Procedures:MOVE CONTR FROM FIRE AREA IF YOU CAN DO IT
W/OUT RISK. DO NOT SCATTER SPILLED MATL W/HIGH PRESS WATER STREAMS.
DIKE FIRE-CTL WATER FOR LATER DISPOSAL (SUP DAT)
Unusual Fire/Explosion Hazard:SLIGHT FIRE HAZARD WHEN EXPOSED TO HEAT
OR FLAME. OSHA CLASS IIIB.

Accidental Release

Spill Release Procedures:STOP LEAK IF YOU CAN DO SO W/OUT RISK. FOR SML
SPILLS, TAKE UP W/SAND DIATOMACEOUS EARTH, CLAY/OTHER INERT ABSORB
& PLACE IN CONTR FOR LATER DISP. KEEP UNNEC PEOPLE AWAY. ISOLATE
HAZ AREA & DENY ENTRY . KEEP PETRO PRODS OUT OF STREAMS, (SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE AWAY FROM INCOMPATIBLE
SUBSTANCES.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:THE FOLLOWING RESP & MAX USE CONCS ARE RECOM BY
U.S. DEPARTMENT OF HLTH & HUMAN SERVICES, NIOSH POCKET GUIDE TO
CHEM HAZ: NIOSH CRITERIA DOCUMENTS/BY U.S. DEPARTMENT OF LABOR, 29
CFR 1910 SUBPART Z. T HE SPEC RESP SELECTED MUST BE (ING 7)
Ventilation:PROVIDE LOCAL EXHAUST VENTILATION AND/OR GENERAL
VENTILATION TO MEET PUBLISHED EXPOSURE LIMITS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:WEAR OIL IMPERVIOUS CLOTHING. AVOID
PROLONGED OR REPEATED CONTACT WITH SUBSTANCE. AVOID WEARING OIL
SOAKED CLOTHING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXTING MEDIA: RESPONSE GUIDEBOOK, RSPA P 5800.6). FIRE FIGHT PROC:
(1993 EMER RESPONSE GUIDEBOOK, RSPA P 5800.6, GUIDE PAGE 31). USE
AGENTS SUITABLE FOR TYPE OF SURROUND FIRE. AVOID BRTHG HAZ VAPS, KE
EP UPWIND. WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP . SPILL
PROC: WATERWAYS & DRAINAGE SYS.

Chemical Properties

Spec Gravity:0.818-0.905
Solubility in Water:INSOLUBLE
Appearance and Odor:WATER-WHITE OILY LIQUID

Stability

Stability Indicator/Materials to Avoid:YES
CHLORINE, NITRIC ACID, STRONG OXIDIZERS, OXYGEN.
Stability Condition to Avoid:MAY BURN BUT DOES NOT IGNITE READILY.
AVOID CONTACT WITH STRONG OXIDIZERS, EXCESSIVE HEAT, SPARKS, OR
OPEN FLAME.
Hazardous Decomposition Products:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE TOXIC OXIDES OF CARBON.

Disposal

Waste Disposal Methods:OBSERVE ALL LOCAL, STATE & FEDERAL REGULATIONS
WHEN STORING OR DISPOSING OF SUBSTANCE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.