BXDLC - MT TONER V, EP8602

  • MSDS: BXDLC
  • Manufacturer: MINOLTA CORP
  • Product Name: MT TONER V, EP8602
  • National Stock Number: 6850-00N058708
Product Identification

Product ID:MT TONER V, EP8602
MSDS Date:03/05/1992
FSC:6850
NIIN:00N058708
MSDS Number: BXDLC

Responsible Party
MINOLTA CORPORATION
101 WILLIAMS DRIVE
RAMSEY, NJ 07446
US

Emergency Phone: 201-825-4000

Info Phone: 201-825-4000

Cage: 23736

Contractor
MINOLTA CORPORATION
RAMSEY, NJ 07446 US

Telephone: 201-825-4000

Cage: 23736

Ingredients

STYRENE ACRYLATE COPOLYMER (2 KINDS)

CAS: 25153-46-2

Fraction By Weight: >85%

OSHA PEL N/K

ACGIH TLV: N/K


CARBON BLACK

CAS: 1333-86-4

RTECS: FF5800000

Fraction By Weight: 5-10%

OSHA PEL 3.5 MG/M3

ACGIH TLV: 3.5 MG/M3


ORGANIC PIGMENT

CAS: 32517-36-5

Fraction By Weight: 1-5%

OSHA PEL N/K

ACGIH TLV: N/K


PROPENE POLYMERS; (POLYPROPYLENE)

CAS: 9003-07-0

RTECS: TR5000000

Fraction By Weight: 1-5%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:LD50 (ORAL RAT): >5.0 G/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: MIN RESP TRACT IRRIT MAY OCCUR
AS W/EXPOS TO LGE AMTS OF ANY NONTOXIC DUST. MAY CAUSE COUGH &
RAISE PHLEGM. TONER PRESENTS A LOW HAZ FOR USUAL OCCUPATIONAL
SETTINGS. BASED ON AVAIL DATA, HUMAN EXPOS TO TONER HAS BEEN SHOWN
TO CAUSE MIN RESP TRACT IRRIT AS MAY OCCUR W/LGE AMTS OF ANY
NONTOXIC (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: DUSTS. THE RSLTS OF ONE ANIMAL STUDY
WHERE RATS INHALED TONER THAT WAS TEN TIMES MORE RESPIRABLE THAN
COMMERCIALLY AVAIL TONER WERE OBSERVED TO HAVE NO LUNG CHANGES AT
LOW EXPOS (THE MOST RE LEVANT LEVEL TO POTENTIAL HUMAN EXPOS).AT
HIGHER LEVELS A SLIGHT DEGREE OF LUNG FIBROSIS WAS OBSERVED DUE TO
(SUP DAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL: WASH NOSTRILS, RINSE MOUTH. INGEST: DILUTE STOMACH
CONTENTS WITH SEVERAL GLASSES OF WATER. EYES: FLUSH WITH WATER FOR
AT LEAST 15 MINUTES. SKIN: WASH WITH SOAP AND WATER.

Fire Fighting

Extinguishing Media:WATER, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:AVOID INHALATION OF SMOKE. WEAR NIOSH/MSHA
APPROVED SCBA & FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:IF DISPERSED IN AIR, TONER, LIKE MOST
FINELY DIVIDED ORGANIC POWDERS, MAY FORM AN EXPLOSIVE MIXTURE.

Accidental Release

Spill Release Procedures:SWEEP UP OR VACUUM.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NONE.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NONE REQUIRED WHEN USED AS INTENDED IN MINOLTA
EQUIPMENT. USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP: EXCESSIVE AMTS OF DUST RETAINED IN LUNGS FOR A PRLNG
INTERVAL. CHRONIC: NONE.

Chemical Properties

Melt/Freeze Pt:M.P/F.P Text:>248F,>120C
Spec Gravity:1.2 (H*2O=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BLACK POWDER, WITH FAINT ODOR

Stability

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:PRODUCTS OF COMBUSTION ARE TOXIC.
AVOID BREATHING OF SMOKE.

Disposal

Waste Disposal Methods:WASTE MAY BE DISPOSED OR INCINERATED UNDER
CONDITIONS WHICH MEET ALL FEDERAL, STATE, AND LOCAL ENVIRONMENTAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.