BXGHH - EC-117(CURING SOLUTION), CORROSION INHIBITING(SUPDAT)
- MSDS: BXGHH
- Manufacturer: CROWN METRO AEROSPACE COATINGS INC
- Product Name: EC-117(CURING SOLUTION), CORROSION INHIBITING(SUPDAT)
- National Stock Number: 8010-00N058822
Product Identification
Product ID:EC-117(CURING SOLUTION), CORROSION INHIBITING(SUPDAT)
MSDS Date:12/01/1988
FSC:8010
NIIN:00N058822
Kit Part:Y
MSDS Number: BXGHH
Responsible Party
US
Emergency Phone: 803-277-1870
Info Phone: 803-277-1870
Cage: CROME
Contractor
Telephone: 803-277-1870
Cage: CROME
Ingredients
ORGANIC AMINE COMPLEX
Fraction By Weight: <5%
OSHA PEL N/K
ACGIH TLV: N/K
22 @ 20C.
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 5%
OSHA PEL 200 PPM
ACGIH TLV: 50 PPM, S
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
21 @ 20C.
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: 10%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM;150 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
90 @ 20C.
CAS: 67-63-0
RTECS: NT8050000
Fraction By Weight: 15%
OSHA PEL 400 PPM
ACGIH TLV: 400 PPM;500 STEL
2-BUTANONE; (METHYL ETHYL KETONE) (MEK) (SARA 313)
CAS: 78-93-3
RTECS: EL6475000
Fraction By Weight: 10-20%
OSHA PEL 200 PPM
ACGIH TLV: 200 PPM;300 STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
0.6 @ 20C.
CAS: 111-76-2
RTECS: KJ8575000
Fraction By Weight: 10%
OSHA PEL 50 PPM, S
ACGIH TLV: 25 PPM, S
(EXTRACTED FROM DHHS (NIOSH) PUBLICATION
RTECS: 9999999ZZ
WEAR CHEMICAL RESISTANT BOOTS.
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CAN CAUSE IRRIT TO SKIN, EYES & RESP
TRACT. SYMPS MAY BE WATERING OF EYES, DRYNESS OF THROAT, COUGH,
HDCH, TIGHTNESS IN CHEST/BURNING SENSATION. ALLERGIC RXNS MAY OCCUR
IN SOME INDIVIDUALS. HDCH, DIZZ /NAUS MAY BE EXPERIENCED BY SOME AS
RSLT OF EXPOS TO SOLVS. NOTE:TOLUENE APPEARS ON NAVY LIST OF OCCUP
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:CHEM REPRO HAZS. SEEK CONSULTATION
FROM APPROP HLTH PROFESSIONALS CONCERNING LATEST HAZ LIST INFO &
SAFE HNDLG & EXPOS INFO . ANIMAL STUDIES CLEARLY DEMONSTRATED
DOSE-RELATED ADVERSE EF TS ON CNS, HEMATOPOIETIC TISS, BLOOD,
KIDNEYS & LIVER, ASSOC W/ADMIN OF ETHYLENE GLYCOL MONOBUTYL ETHER
(EGBE). (ING 7)
Medical Cond Aggravated by Exposure:PERSONS W/ASTHMATIC TYPE
CONDITIONS, CHRONIC BRONCHITIS OR OTHER CHRONIC RESPIRATORY
DISEASES OR RECURRENT SKIN ECZEMA OR SENSITIZATION SHOULD BE
EXCLUDED FROM WORKING W/THIS PRODUCT.
First Aid
First Aid:EYE:FLUSH W/WATER FOR AT LEAST 15 MINUTES. CONSULT MD.
SKIN:WASH AFFECTED AREA W/SOAP & WATER. REMOVE CONTAMINATED
CLOTHING. CONSULT MD. INHAL:REMOVE TO FRESH AIR. CONSULT MD.
INGEST:DRINK WATER TO DI LUTE. DO NOT INDUCE VOMITING. CONSULT MD.
Fire Fighting
Flash Point Method:TCC
Flash Point:23.0F,-5.0C
Lower Limits:1%
Extinguishing Media:FOAM, CO*2, DRY CHEMICAL, WATER FOG.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
WATER SPRAY MAY BE INEFT. IF WATER IS USED, FOG NOZZS ARE PREF.
WATER MAY BE USED TO COOL CLSD (SUPP DATA)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, SPKS, ELEC EQUIP & OPEN FLAME. CLSD CNTNRS MAY EXPLODE WHEN
EXPOS TO EXTREME HEAT. APPLICATION TO HOT SURFS(SUPDAT)
Accidental Release
Spill Release Procedures:EVACUATE NON-ESSENTIAL PERSONNEL. REMOVE ALL
SOURCES OF IGNITION (SPARKS, FLAMES, HOT SURFACES). VENTILATE AREA.
EQUIP CLEAN-UP CREW W/NIOSH/MSHA APPRVD SCBA. DIKE SPILL. COVER
W/SAWDUST, VERMICULITE, FULLER'S EARTH. COLLECT MATL IN OPEN
CONTAINERS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT STORE ABOVE 100F. STORE LARGE
QUANTITIES ONLY IN BUILDINGS DESIGNED TO COMPLY W/OSHA 1910.106. DO
NOT STORE NEAR HEAT, SPARKS OR FLAMES.
Other Precautions:KEEP ALL CONTAINERS CLOSED & UPRIGHT TO PREVENT
LEAKAGE. AVOID BREATHING SANDING DUST (NIOSH/MSHA APPROVED
RESPIRATOR REQUIRED). AVOID PROLONGED OR REPEATED CONTACT W/VAPOR
OR SPRAY MIST DURING APPLIC ATION OR CURING.
Exposure Controls
Respiratory Protection:IN OUTDOOR/OPEN AREAS USE NIOSH/MSHA APPRVD MECH
FILTER RESPS. IN RESTRICTED VENT AREAS, USE NIOSH/MSHA APPRVD
CHEM/MECH FILTERS TO REMOVE VAP & PARTICULATES. IN CONFINED AREAS
USE NIOSH/MSHA APPRVD A IR LINE TYPE RESPIRATORS OR HOODS.
Ventilation:MUST BE SUFFICIENT IN VOLUME & PATTERN TO KEEP CONTAMINANT
CONCENTRATION BELOW TLV (NIOSH) OR PEL (OSHA).
Protective Gloves:BUTYL RUBBER GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . PROT CREAMS WHERE SKIN CONT IS LIKELY. (ING
8)
Work Hygienic Practices:WASH HANDS BEFORE EATING OR USING BATHROOM.
REMOVE & WASH ANY CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO:PRIMER YELLOW BAC-377, PART B. FIRE FIGHT
PROC:CNTNRS TO PVNT PRESS BUILD-UP & POSS AUTOIGNIT/EXPLO WHEN
EXPOS TO EXTREME HEAT. EXPLO HAZ:REQS SPECIAL PRECS. DURING EMER
CNDTN S, OVEREXP TO DECOMP PRODS MAY CAUSE HLTH HAZ. SYMPS MAY NOT
BE IMMED APPARENT. OBTAIN MED ATTN.
Chemical Properties
Boiling Pt:B.P. Text:>170F,>77C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:1.05
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:65
Stability
Stability Indicator/Materials to Avoid:YES
AVOID CONTACT W/STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:TEMPERATURES ABOVE MAXIMUM STORAGE
TEMPERATURE. AVOID EXPOSURE TO HEAT, SPARKS OR OPEN FLAMES.
Hazardous Decomposition Products:BY FIRE - CO, CO*2 & NITROGEN OXIDES.
Disposal
Waste Disposal Methods:CONFORM TO FEDERAL, STATE & LOCAL REGULATIONS.
EMPTY CONTAINERS MUST BE HANDLED CAREFULLY DUE TO PRODUCT RESIDUE &
FLAMMABLE SOLVENT VAPOR.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.