BXGRH - 97-47 (121890E), AQUAPON BROWN INHIBITIVE (SUP DAT)
- MSDS: BXGRH
- Manufacturer: PPG INDUSTRIES INC
- Product Name: 97-47 (121890E), AQUAPON BROWN INHIBITIVE (SUP DAT)
- National Stock Number: 8010-00N059267
Product Identification
Product ID:97-47 (121890E), AQUAPON BROWN INHIBITIVE (SUP DAT)
MSDS Date:07/01/1992
FSC:8010
NIIN:00N059267
MSDS Number: BXGRH
Responsible Party
ALLISON PARK, PA 15101
US
Emergency Phone: 302-843-1300
Info Phone: 412-492-5555
Cage: 47695
Contractor
Telephone: 1-800-245-2974 (CAL HYPO)
Cage: 47695
Ingredients
SILICA, AMORPHOUS-FUMED
CAS: 112945-52-5
RTECS: VV7310000
Fraction By Weight: 1-2%
OSHA PEL 6 MG/M3
ACGIH TLV: 10 MG/M3
IRON OXIDE
CAS: 1309-37-1
RTECS: NO7400000
Fraction By Weight: 2-5%
OSHA PEL 10 MG/M3 (FE)
ACGIH TLV: 5MG(FE)/M3FUME,B2
TALC (POWDER), CONTAINING NO ASBESTOS FIBERS; (MAGNESIUM
CAS: 14807-96-6
RTECS: WW2710000
Fraction By Weight: 15-20%
OSHA PEL 2 MG/M3 RDUST
ACGIH TLV: 2 MG/M3 RDUST
PHOSPHORIC ACID, ZINC SALT; (ZINC PHOSPHATE)
CAS: 7779-90-0
RTECS: TD0590000
Fraction By Weight: 25-30%
OSHA PEL N/K
ACGIH TLV: N/K
ISOPROPYL ALCOHOL (SARA 313)
CAS: 67-63-0
RTECS: NT8050000
Fraction By Weight: 5-10%
OSHA PEL 400 PPM
ACGIH TLV: 400 PPM/500STEL
XYLENE (SARA 313) (CERCLA)
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: 10-15%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM/150STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
TOLUENE (SARA 313) (CERCLA)
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 5-10%
OSHA PEL 200 PPM; Z-2
ACGIH TLV: 50 PPM, S
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
ETHANOL, 2-PROPOXY-; (ETHYLENE GLYCOL MONOPROPYL ETHER)
CAS: 2807-30-9
RTECS: KM2800000
Fraction By Weight: 2-5%
OSHA PEL N/K
ACGIH TLV: N/K
FILM FORMERS, RESINS, AND ADDITIVES
Fraction By Weight: 15-20%
OSHA PEL N/K
ACGIH TLV: N/K
HAZ. SEEK CONSULTATION FROM APPROP HLTH
RTECS: 9999999ZZ
EYE
RTECS: 9999999ZZ
INDICATIONS THAT SOLV LEVELS ARE TOO HIGH. REDNESS,
RTECS: 9999999ZZ
INDICATE EXCESSIVE EYE CONT. DRYNESS, ITCH,
RTECS: 9999999ZZ
WITH EXCESSIVE SKIN CONTACT.
RTECS: 9999999ZZ
CTR, EMER ROOM/MD IMMED. HAVE MATL SFTY
RTECS: 9999999ZZ
DETERMINE TYPE OF AIRBORNE CONTAMINANTS AGAINST
RTECS: 9999999ZZ
LEL BELOW STATED LIMIT, & TO REMOVE DECOMP PRODS
RTECS: 9999999ZZ
GOGGLES AND FULL FACESHIELD .
RTECS: 9999999ZZ
Fire Fighting
Flash Point Method:PMCC
Flash Point:59.0F,15.0C
Lower Limits:1.5%
Extinguishing Media:NFPA CLASS B EXTING (CO*2, DRY CHEM/UNIVERSAL
AQEOUS FILM FORMING FOAM) DESIGNED TO EXTING NFPA CLASS 1B FLAM LIQ
FIRES.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT . WATER SPRAY MAY BE INEFFECTIVE. IT MAY BE
USED TO COOL CLSD CONTRS TO PREVENT PRESS (SUP DAT)
Unusual Fire/Explosion Hazard:KEEP CONTRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPARKS & OPEN FLAMES. CLSD CONTRS MAY EXPLODE
WHEN EXPOSED TO EXTREME HEAT. DO NOT APPLY ON (SUP DAT)
Exposure Controls
Supplemental Safety and Health
Chemical Properties
Boiling Pt:B.P. Text:>180F,>82C
Vapor Pres:17.7
Vapor Density:HVR/AIR
Spec Gravity:1.45
Evaporation Rate & Reference:153 (BUTYL ACETATE=100)
Solubility in Water:8.4%
Appearance and Odor:VISCOUS LIQUID W/AN ODOR CHARACTERISTIC OF THE
SOLVENTS LISTED IN INGS SECTION
Percent Volatiles by Volume:44.80
Stability
Stability Indicator/Materials to Avoid:YES
AVOID CONT WITH STRONG ALKALIES, STRONG MINERAL ACIDS, OR STRONG
OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.