BXGRV - ENGINE DEGREASER, 5025

  • MSDS: BXGRV
  • Manufacturer: CRC INDUSTRIES
  • Product Name: ENGINE DEGREASER, 5025
  • National Stock Number: 6850-00N059284
Product Identification

Product ID:ENGINE DEGREASER, 5025
MSDS Date:02/12/1993
FSC:6850
NIIN:00N059284
MSDS Number: BXGRV

Responsible Party
CRC INDUSTRIES
885 LOUIS DR
WARMINSTER, PA 18974
US

Emergency Phone: 215-674-4300

Info Phone: 215-674-4300

Preparer: JOHN BROWN

Cage: JO037

Contractor
CRC INDUSTRIES, INC.
WARMINSTER, PA 18974-2820 US

Telephone: 215-674-4300/800-424-9300

Cage: 10136

Ingredients

XYLENE

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 17%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


PETROLEUM MID-DISTILLATE; (PETROLEUM DISTILLATE)

CAS: 68476-34-6

Fraction By Weight: 62%

OSHA PEL 400 PPM (MFR)

ACGIH TLV: N/K


GLYCOLS, POLYETHYLENE, MONO(P-NONYLPHENYL)ETHER;

CAS: 26027-38-3

RTECS: MD0906000

Fraction By Weight: 6%

OSHA PEL N/K

ACGIH TLV: N/K


PROPANE

CAS: 74-98-6

RTECS: TX2275000

Fraction By Weight: 7.61%

OSHA PEL 1000 PPM

ACGIH TLV: ASPHYXIANT


PROPANE, 2-METHYL; (ISOBUTANE)

CAS: 75-28-5

RTECS: TZ4300000

Fraction By Weight: 8%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHALATION:DIZZINESS, NAUSEA,
BREATHING DIFFICULTIES. EYES:MAY BE IRRITATING. SKIN:TENDS TO DEFAT
AND IRRITATE SKIN. CHRONIC:CONTACT DERMATITIS.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:BREATHING DIFFICULTIES.

First Aid

First Aid:INHALATION:REMOVE TO FRESH AIR. APPLY ARTIFICIAL RESPIRATION
IF NECESSARY. EYES:FLUSH WITH LARGE AMOUNTS OF WATER FOR AT LEAST
15 MINUTES. SKIN:WASH WITH LARGE AMOUNTS OF WATER. INGESTION:DO NOT
INDUC E VOMITING. CALL A PHYSICIAN.

Fire Fighting

Flash Point Method:TCC
Flash Point:<20F,<-7C
Extinguishing Media:FOG. CARBON DIOXIDE. FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:INITIAL FLASH POINT DUE TO PROPELLENTS IS
<20F. AEROSOL CANS MAY EXPLODE IF HEATED ABOVE 120F.

Accidental Release

Spill Release Procedures:NOT NORMALLY A PROBLEM WITH AEROSOLS-REMOVE
SOURCES OF IGNITION AND VENTILATE. ABSORB ON INERT MATERIAL AND
PLACE IN A CLOSED CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN COOL, DRY AREA.
Other Precautions:AEROSOL CONTAINERS MAY EXPLODE WHEN HEATED ABOVE
120F.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED SELF CONTAINED BREATHING
APPARATUS FOR CONCENTRATION ABOVE THE TLV.
Ventilation:ADEQUATE TO MAINTAIN VAPOR CONCENTRATION BELOW THE TLV.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED SAFETY GLASSES .
Other Protective Equipment:NOT NORMALLY REQUIRED FOR AEROSOL PRODUCT
USAGE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Boiling Pt:B.P. Text:220F,104C
Vapor Density:>AIR
Spec Gravity:0.857
Evaporation Rate & Reference:SLOW
Solubility in Water:EMULSIFIES
Appearance and Odor:CLEAR, LIGHT AMBER LIQUID.
Percent Volatiles by Volume:68

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:THERMAL-CARBON MONOXIDE.

Disposal

Waste Disposal Methods:ALL USED AND UNUSED PRODUCT SHOULD BE DISPOSED
OF IN CONFORMANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.