BXJBT - STAINLESS STEEL FIBER

  • MSDS: BXJBT
  • Manufacturer: RIBBON TECHNOLOGY CORP
  • Product Name: STAINLESS STEEL FIBER
  • National Stock Number: 9515-00N058994
Product Identification

Product ID:STAINLESS STEEL FIBER
MSDS Date:10/07/1993
FSC:9515
NIIN:00N058994
MSDS Number: BXJBT

Responsible Party
RIBBON TECHNOLOGY CORP
GAHANNA, OH 43230
US

Emergency Phone: 614-864-5444

Info Phone: 614-864-5444

Cage: 45872

Contractor
RIBBON TECHNOLOGY CORP
30758 GAHANNA, OH 43230 US

Telephone: 614-864-5444

Cage: 45872

Ingredients

IRON (III) OXIDE

CAS: 1309-37-1

RTECS: NO7400000

Fraction By Weight: 60-88%

OSHA PEL 10 MG/M3 (FE)

ACGIH TLV: 5MG(FE)/M3FUME,B2


CHROMIUM (SARA 313) (CERCLA)

CAS: 7440-47-3

RTECS: GB4200000

Fraction By Weight: 10-30%

OSHA PEL 1 MG/M3

ACGIH TLV: 0.5 MG/M3

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


NICKEL (SARA 313) (CERCLA)

CAS: 7440-02-0

RTECS: QR5950000

Fraction By Weight: 0-27%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3


MANGANESE (SARA 313)

CAS: 7439-96-5

RTECS: OO9275000

Fraction By Weight: <6%

OSHA PEL C 5 MG/M3 DUST

ACGIH TLV: 5 MG/M3 DUST 9495


MOLYBDENUM (SARA 313)

CAS: 7439-98-7

RTECS: QA4680000

Fraction By Weight: <6%

OSHA PEL 5 MG(MO)/M3

ACGIH TLV: 5 MG(MO)/M3


COPPER (SARA 313) (CERCLA)

CAS: 7440-50-8

RTECS: GL5325000

Fraction By Weight: <6%

OSHA PEL 0.1MG/M3 FUME/1 DUST

ACGIH TLV: 0.2 MG/M3 FUME

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


TITANIUM

CAS: 7440-32-6

RTECS: XR1700000

Fraction By Weight: <6%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


CARBON PRODUCTS

Fraction By Weight: <2%

OSHA PEL 3.5 MG/M3

ACGIH TLV: 3.5 MG/M3


PHOSPHORUS (WHITE) (SARA 302)

CAS: 7723-14-0

RTECS: TH3500000

Fraction By Weight: <2%

OSHA PEL N/K

ACGIH TLV: N/K

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


SULFUR (SARA 302)

CAS: 7704-34-9

RTECS: WS4250000

Fraction By Weight: <2%

OSHA PEL 5 PPM

ACGIH TLV: 2 PPM/5 STEL


SILICON

CAS: 7440-21-3

RTECS: VW0400000

Fraction By Weight: <2%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


COBALT (SARA 313)

CAS: 7440-48-4

RTECS: GF8750000

Fraction By Weight: <2%

OSHA PEL 0.1 MG/M3

ACGIH TLV: 0.02 MG/M3


NIOBIUM

CAS: 7440-03-1

RTECS: QT9900000

Fraction By Weight: <2%

OSHA PEL N/K

ACGIH TLV: N/K


NITROGEN

CAS: 7727-37-9

RTECS: QW9700000

Fraction By Weight: <2%

OSHA PEL N/K

ACGIH TLV: ASPHYXIANT


TIN

CAS: 7440-31-5

RTECS: XP7320000

Fraction By Weight: <2%

OSHA PEL 2 MG/M3

ACGIH TLV: 2 MG/M3


CONGESTION AND EDEMA. ARC OR SPARK GENERATED

RTECS: 9999999ZZ


FOR COMBUSTIBLE AND FLAMMABLE MATERIALS.

RTECS: 9999999ZZ


WELDING, SAWING, BRAZING & GRINDING MAY RELEASE

RTECS: 9999999ZZ


ANNUAL REPORT ON CARCINOGENS, 1994

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: SHORT TERM EXPOS TO FUMES/DUST
MAY PRODUCE IRRIT OF EYES & RESP SYS. INHAL OF HIGH CONCS OF
FRESHLY FORMED OXIDE FUMES/IRON, MANGANESE & COPPER MAY CAUSE METAL
FUME FEVER CHARACTERIZED BY A MET ALLIC TASTE IN MOUTH, DRYNESS &
IRRIT OF THROAT & INFLUENZA-LIKE SYMP. CHRONIC: INHAL OF HIGH CONCS
OF (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NICKEL: IARC MONO ON EVALUATION OF
CARCINOGENIC RISK OF CHEM TO MAN, VOL 49, PG 257, 1990: GROUP 2B.
NTP 7TH (ING 19)
Effects of Overexposure:HLTH HAZ: IRON OXIDE FUMES/DUST MAY LEAD TO A
BENIGN PNEUMOCONIOSIS (SIDEROSIS). INHAL OF HIGH CONCS OF FERRIC
OXIDE MAY POSS ENHANCE RISK OF LUNG CANCER DEVELOPMENT IN WORKERS
EXPOSED TO PULM CARCINO GENS. CHROMIUM & NICKEL & THEIR CMPDS ARE
LISTED IN THE 3RD ANNUAL REPORT ON CARCINOGENS, AS PREPARED BY THE
(SUP DAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR. SEEK MD AID IMMEDIATELY. EYES:
FLUSH WITH WATER FOR AT LEAST 15 MINUTES. SKIN: FLUSH WITH COPIOUS
AMOUNTS OF WATER. SEE MD . INGEST: CALL MD IMMEDIATELY .

Fire Fighting

Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT . STEEL PRODUCTS IN THE SOLID STATE PRESENT NO
FIRE OR EXPLOSION HAZARD.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:THIS MATERIAL MAY BE RECLAIMED FOR REUSE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:IN WELDING, PREC SHOULD BE TAKEN FOR AIRBORNE
CONTAMINANTS WHICH MAY ORIGINATE FROM COMPONENTS OF WELDING ROD.
PLASMA ARC CUTTING/WELDING CAN GENERATE OZONE. OVEREXP CAN RSLT IN
MUC MEMB IRRIT AS WELL AS PULM CHANGES INCL IRRIT, (ING 16)

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED DUST AND FUME RESPIRATOR
TO AVOID EXCESSIVE INHALATION OF PARTICULATES WHEN EXPOSURE EXCEEDS
TLV.
Ventilation:LOC EXHAUST VENT SHOULD BE UTILIZED WHEN WELDING, BURNING,
SAWING, BRAZING, GRINDING/MACHINING WHEN EXPOS EXCEEDS TLV.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:OTHER PROTECTIVE EQUIPMENT SHOULD BE
UTILIZED AS REQUIRED BY THE WELDING STANDARDS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP: NATIONAL TOXICOLOGY PROGRAM (NTP). EXPOS TO HIGH CONCS
OF DUST & FUMES CAN CAUSE SENSIT, DERM, INFLAMM &/ULCERATION OF
UPPER RESP TRACT & POSS CANCER OF NASAL PASSAGES & LUNGS. NOTE:
STEEL PROD IN NATURAL STATE DO NOT PRESENT INHAL, INGEST/CONT HAZ.
HOWEVER, OPERATIONS SUCH AS BURNING, (ING 18)

Chemical Properties

Melt/Freeze Pt:M.P/F.P Text:>2500F,>137
Spec Gravity:7
Appearance and Odor:GRAY-BLACK SOLID, ODORLESS

Stability

Stability Indicator/Materials to Avoid:YES
REACTS WITH STRONG ACIDS TO PRODUCE HYDROGEN GAS.
Stability Condition to Avoid:NOT APPLICABLE.
Hazardous Decomposition Products:METALLIC DUST OR FUMES MAY BE PRODUCED
DURING WELDING, BURNING, GRINDING AND POSSIBLE MACHINING. REFER TO
ANSI Z49.1.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE &
FEDERAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.