BXJND - MAGNESIUM STANDARD 1000 PPM, M-122

  • MSDS: BXJND
  • Manufacturer: RED BIRD SERVICE
  • Product Name: MAGNESIUM STANDARD 1000 PPM, M-122
  • National Stock Number: 6810-00N059538
Product Identification

Product ID:MAGNESIUM STANDARD 1000 PPM, M-122
MSDS Date:09/10/1992
FSC:6810
NIIN:00N059538
MSDS Number: BXJND

Responsible Party
RED BIRD SERVICE
205 WESTERN AVE
OSGOOD, IN 47037
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 800-428-3502

Preparer: GENE C FEITH

Cage: 0H0Z7

Contractor
RED BIRD SERVICE
OSGOOD, IN 47037 US

Telephone: 812-689-4040;800-428-3502

Cage: 0H0Z7

Ingredients

NITRIC ACID (SARA 302/313) (CERCLA)

CAS: 7697-37-2

RTECS: QU5775000

Fraction By Weight: <1.0%

OSHA PEL 2 PPM

ACGIH TLV: 2 PPM/4 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


4); (MANGANESE

CAS: 10101-68-5

RTECS: OP1200000

Fraction By Weight: <1.0%

OSHA PEL N/K

ACGIH TLV: N/K


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: BALANCE

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MAY CAUSE IRRITATION TO THE EYES, SKIN
& RESPIRATION TRACT. INGESTION MAY CAUSE BURNING SENSATION,
VOMITING & DIARRHEA. CONTACT LENSES POSE A SPECIAL HEALTH HAZARD;
SOFT LENSES ABSORB AND ALL LENSES C ONCENTRATE IRRITANTS.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYE: FLUSH W/RUNNING WATER FOR AT LEAST 15 MINS, INCLG UNDER
EYELIDS. CONTACT MD. SKIN: WASH EXPOSED AREA W/SOAP & WATER. GET
MED ADVICE IF IRRIT DEVELOPS. INHAL: REMOVE TO FRESH AIR. GET MED
ATTN FOR ANY BREATHING DFCLTY. INGEST: GIVE SEVERAL GLASSES OF
WATER TO DRINK TO DILUTE. IF LARGE AMOUNTS WERE SWALLOWED, GET MED
ADVICE.

Fire Fighting

Flash Point:NON FLAMMABLE
Extinguishing Media:USE THAT WHICH IS APPROPRIATE FOR THE SURROUNDING
FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:NEUTRALIZE SPILL WITH SODIUM BICARBONATE OR
SODA ASH. DO NOT OVER NEUTRALIZE. NEUTRALIZED WASTE MAY BE
CONTAINERIZED & DISP OF IN AN APPROVED WASTE DISPOSAL FACILITY.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP IN A TIGHTLY CLOSED CNTNR, STORED
IN COOL, DRY, VENTILATED AREA. PROTECT AGAINST PHYSICAL DAMAGE.
PROTECT AGAINST FREEZING.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NOT EXPECTED TO REQUIRE A RESPIRATOR. USE
NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN.
Ventilation:GENERAL.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS.
Other Protective Equipment:MAINTAIN EYE-WASH STATIONS & SAFETY SHOWERS
IN THE WORK AREA.
Work Hygienic Practices:LAUNDER ALL CONTAMD CLOTHING BEFORE REUSE.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:32.0F,0.0C
Vapor Pres:14(WATER)
Vapor Density:0.7(WATER)
Spec Gravity:1 (H*2O=1)
Evaporation Rate & Reference:1.1 (WATER)
Solubility in Water:COMPLETE
Appearance and Odor:A CLEAR, COLORLESS LIQUID W/NO ODOR.
Percent Volatiles by Volume:99

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:STABLE UNDER ORDINARY CONDITIONS OF USE
AND STORAGE.
Hazardous Decomposition Products:MAY EMIT TOXIC FUMES OF NO*X, HYDROGEN
NITRATE & SO*X.

Disposal

Waste Disposal Methods:DISPOSAL: FOLLOW ALL STATE, LOCAL & FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.