BXJPG - PHOSPHATE REAGENT 2, R5199
- MSDS: BXJPG
- Manufacturer: CALGON CORP
- Product Name: PHOSPHATE REAGENT 2, R5199
- National Stock Number: 6850-00N059597
Product Identification
Product ID:PHOSPHATE REAGENT 2, R5199
MSDS Date:08/06/1991
FSC:6850
NIIN:00N059597
MSDS Number: BXJPG
Responsible Party
US
Emergency Phone: 412-777-8000
Info Phone: 412-777-8000
Preparer: PATRICIA A. PACELLA
Cage: 86035
Contractor
Telephone: 412-494-8000
Cage: 86035
Ingredients
2140 MG/KG
CAS: 7664-93-9
RTECS: WS5600000
Fraction By Weight: 7%
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3/3
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:SEE INGREDIENTS
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INGEST:BECAUSE OF CORR NATURE OF
MATL, IF SWALLOWED, PROD WOULD BE EXPECTED TO CAUSE BURNS TO MOUTH,
STOM & GI TRACT, CAUSING NAUS, VOMIT & DIARR. INHAL:MAY CAUSE IRRIT
TO NOSE & THROAT. SKIN:PR OD IS NOT EXPECTED TO PRDCE SYSTEMIC TOX
IF ABSORBED. PROD MAY PRDCE BURNS UPON CONT. SEVERITY OF BURN (EFTS
OF OVEREXP)
Explanation of Carcinogenicity:SULFURIC ACID:IARC MONOGRAPHS ON EVAL OF
CARCIN RISK OF CHEM TO MAN, VOL 54, PG 41, 1992:GROUP 1 ANIMAL:PULM
IRRIT.
Effects of Overexposure:HLTH HAZS:IS GENERALLY DETERM BY CONC OF SOLN &
DURATION OF EXPOS. IT IS NOT EXPECTED THAT CONT W/PROD WOULD PRDCE
SENSIT. EYES:PROD MAY PRDCE BURNS UPON CONT. CHRONIC:REPEATED OR
PROLONGED INHALATION OF SULFURIC ACID MISTS CAN CAUSE INFLAMMATION
OF UPPER RESPIRATORY TRACT LEADING TO CHRONIC BRONCHITIS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES:IMMEDIATELY FLUSH WITH PLENTY OF WATER FOR AT LEAST 15
MINUTES. SEEK MEDICAL AID. SKIN:IMMEDIATELY WASH WITH SOAP AND
PLENTY OF WATER FOR AT LEAST 15 MINUTES WHILE REMOVING CONTAMINATED
CLOTHING. SEEK MEDICAL AID. INGESTION:DO NOT INDUCE VOMITING. GIVE
LARGE QUANTITIES OF WATER. SEEK MEDICAL AID IMMEDIATELY. NEVER GIVE
ANYTHING BY MOUTH TO AN UNCON PERSON. INHALATION:REMOVE TO FRESH
AIR.
Fire Fighting
Flash Point:NONFLAM/COMBUST
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE . THIS PRODUCT
IS NOT FLAMMABLE OR COMBUSTIBLE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT . EXERCISE CAUTION WHEN FIGHTING ANY CHEMICAL
FIRE.
Accidental Release
Spill Release Procedures:DISPOSE OF OIN ACCORDANCE WITH LOCAL, STATE
AND FEDERAL REGS. DIKE AREA TO CONTAIN AS MUCH SPILLED MATL AS
POSSIBLE. REMOVE ANY REMAINING MAT BY ABSORBING ON VERMICULITE OR
OTHER SUITABLE ABSORBING MA TERIAL & PLACE IN SEALED METAL CNTNR
FOR DISP.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DANGER! MAY CAUSE SEVERE EYE AND SKIN
DMG. MAY BE HARMFUL IF SWALLOWED. AVOID BRTHG MISTS & VAPS. DO NOT
GET IN EYES, ON SKIN OR ON CLOTHING.
Other Precautions:KEEP CONTAINER CLOSED WHEN NOT IN USE. USE ONLY IN
WELL-VENTILATED AREAS THAT WILL MAINTAIN AIR LEVELS BELOW LIMITS
ESTABLISHED BY LOCAL, STATE AND FEDERAL REGULATIONS.
Exposure Controls
Respiratory Protection:NOT REQUIRED; HOWEVER, A NIOSH/MSHA APPROVED
RESPIRATOR SHOULD BE USED IF THE RECOMMENDED TLV CONCENTRATIONS ARE
EXCEEDED (SEE INGREDIENTS).
Ventilation:LOC/MECH (GEN):RECOM. USE ONLY IN WELL-VENT AREAS THAT WILL
MAINTAIN AIR LEVELS BELOW LIMS ESTABLISHED BY LOC, (SUP DAT)
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT)
Other Protective Equipment:EMERGENCY EYE WASH & DELUGE SHOWER WHICH
MEET ANSI DESIGN CRITERIA . RUBBER APRON.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
VP:SIMILAR TO WATER. VAP DENS:SIMILAR TO WATER. VENT:STATE AND FEDERAL
REGULATIONS. EYE PROT:AND FULL LENGTH FACE SHIELD .
Chemical Properties
Boiling Pt:B.P. Text:212F,100C
Vapor Pres:SUPP DATA
Vapor Density:SUPP DATA
pH:<1
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR, COLORLESS SOLUTION.
Percent Volatiles by Volume:92
Stability
Stability Indicator/Materials to Avoid:YES
STRONG BASES.
Hazardous Decomposition Products:THERMAL DECOMPOSITION PRODUCTS INCLUDE
HIGHLY TOXIC FUMES OF SULFUR OXIDES.
Disposal
Waste Disposal Methods:DISPOSE OF IN AN APPROVED LANDFILL IN ACCORDANCE
WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS. THIS PRODUCT AS SOLD
MEETS CRITERIA OF CORROSIVITY FOR A RCRA HAZARDOUS WASTE AS DEFINED
IN 40 CFR PART 261.22. EPA HAZ WASTE # FOR CORROSIVITYIS D002.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.