BXJSM - 0402-0866, PILOCARPINE HYDROCHLORIDE (SUPP DATA)
- MSDS: BXJSM
- Manufacturer: STERIS LABORATORIES INC
- Product Name: 0402-0866, PILOCARPINE HYDROCHLORIDE (SUPP DATA)
- National Stock Number: 6505-00N059880
Product Identification
Product ID:0402-0866, PILOCARPINE HYDROCHLORIDE (SUPP DATA)
MSDS Date:05/15/1991
FSC:6505
NIIN:00N059880
MSDS Number: BXJSM
Responsible Party
PHOENIX, AR 85043
US
Emergency Phone: 602-278-1400
Info Phone: 602-278-1400
Preparer: JANET MEHTA
Cage: 0BZC5
Contractor
Telephone: 602-278-2400
Cage: 0BZC5
Ingredients
PILOCARPINE, MONOHYDROCHLORIDE; (PILOCARPINE HYDROCHLORIDE)
CAS: 54-71-7
RTECS: TK1450000
Fraction By Weight: 1-6%
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYE, SKIN &/OR RESPIRATORY TRACT
IRRITATION. SWEATING, WATER NASAL DISCHARGE, ERUCTATION,
LACRIMATION, INVOLUNTARY DEFECATION & URINATION, FLUSHING, MIOSIS,
CONJUNCTIVAL CONGESTION, CILIARY SPAS M, HYSTAGMUS, FEAR,
RESTLESSNESS, EXCESSIVE DREAMING, INCREASED BRONCHIAL SECRETION
W/BRONCHO (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:CONSTRICTION, BRADYCARDIA, HYPOTENSION
& COMA. ALSO, DEATH MAY OCCUR DUE TO CARDIAC ARREST, CENTRAL
RESPIRATORY PARALYSIS OR PULMONARY EDEMA. CHRONIC:POSSIBLE
HYPERSENSITIZATION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYE:FLUSH W/WATER FOR AT LEAST 15 MINUTES. SEEK MEDICAL
ADVICE/ATTENTION. SKIN:REMOVE CONTAMINATED CLOTHING. FLUSH W/WATER.
SEEK MEDICAL ADVICE/ATTENTION. INHAL:REMOVE PERSON TO FRESH AIR.
SEEK MEDICA L ATTENTION. INGEST:FLUSH MOUTH W/WATER. SEEK MEDICAL
ADVICE/ATTENTION.
Fire Fighting
Extinguishing Media:WATER SPRAY, DRY CHEMICAL, CARBON DIOXIDE OR FOAM,
AS APPROPRIATE FOR SURROUNDING MATERIALS & FIRE.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:EMITS TOXIC FUMES.
Accidental Release
Spill Release Procedures:WEAR THE RECOMMENDED PERSONAL PROTECTIVE
EQUIPMENT. WIPE WORKING SURFACE TO DRYNESS, THEN WASH W/SOAP &
WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:HANDLE ALL PHARMACEUTICAL PRODUCTS IN
A WAY THAT WILL AVOID CONTACT WITH & INHALATION OF DUST, FUMES,
MISTS &/OR VAPORS ASSOCIATED W/THE PRODUCT.
Other Precautions:STORE IN COOL PLACE (8-27C).
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation:LOCAL EXHAUST RECOMMENDED.
Protective Gloves:DISPOSABLE, SURGICAL LATEX GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . DISPOSABLE PROT APPAREL (PROT EXPOSED SKIN).
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO:OPHTHALMIC SOLUTION, USP. PH:3.5-5.5.
Chemical Properties
Spec Gravity:1.01 (H*2O=1)
pH:SUPDAT
Solubility in Water:SOLUBLE
Appearance and Odor:CLEAR, PRACTICALLY COLORLESS SOLUTION; NO ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
AVOID SILVER NITRATE, MERCURY BICHLORIDE, IODIDES, GOLD SALTS, TANNIN,
CALOMEL, KMNO*4 & ALKALIES.
Stability Condition to Avoid:EXPOSURE TO LIGHT MAY CAUSE DECOMPOSITION.
Hazardous Decomposition Products:EMITS TOXIC FUMES OF HCL & NO*X.
Disposal
Waste Disposal Methods:DISPOSE OF I/A/W FEDERAL, STATE & LOCAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.