BXJTT - 2004 MOSS GREEN, INDUSTRIAL MAINTENANCE & (SUPDAT)

  • MSDS: BXJTT
  • Manufacturer: SHERWIN WILLIAMS CO
  • Product Name: 2004 MOSS GREEN, INDUSTRIAL MAINTENANCE & (SUPDAT)
  • National Stock Number: 8010-00-397-2982
Product Identification

Product ID:2004 MOSS GREEN, INDUSTRIAL MAINTENANCE & (SUPDAT)
MSDS Date:01/04/1993
FSC:8010
NIIN:00-397-2982
MSDS Number: BXJTT

Responsible Party
SHERWIN WILLIAMS CO
101 PROSPECT AVE NW
CLEVELAND, OH 44115-1042
US

Emergency Phone: 216-294-7400

Info Phone: 800-247-3266

Cage: 54626

Contractor
SHERWIN-WILLIAMS CO THE
CLEVELAND, OH 44115-1042 US

Telephone: 800-251-2486/216-566-2242

Cage: 54636

Ingredients

760

CAS: 74-98-6

RTECS: TX2275000

Fraction By Weight: 18%

OSHA PEL 1000 PPM

ACGIH TLV: ASPHYXIANT


7.1

CAS: 100-41-4

RTECS: DA0700000

Fraction By Weight: 1%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM/125STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


6.9

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 7%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM/150STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


180

CAS: 67-64-1

RTECS: AL3150000

Fraction By Weight: 37%

OSHA PEL 1000 PPM

ACGIH TLV: 750PPM/1000STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


2-BUTANONE; (METHYL ETHYL KETONE) (MEK) (SARA 313)

CAS: 78-93-3

RTECS: EL6475000

Fraction By Weight: 12%

OSHA PEL 200 PPM

ACGIH TLV: 200 PPM/300 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


2-PENTANONE, 4-METHYL-; (METHYL ISOBUTYL KETONE) (SARA 313)

CAS: 108-10-1

RTECS: SA9275000

Fraction By Weight: 3%

OSHA PEL 100 PPM

ACGIH TLV: 50 PPM/75 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ACETIC ACID, 2-METHOXY-1-METHYLETHYL ESTER;

CAS: 108-65-6

RTECS: AI8295000

Fraction By Weight: 8%

OSHA PEL N/K

ACGIH TLV: N/K


VOLATILE ORGANIC CONTENT AS A PERCENT BY WT PER BAAQMD RULE

RTECS: 9999999VO

OSHA PEL N/K

ACGIH TLV: N/K


SUNLIGHT, RADIATORS, STOVES, HOT WATER, AND OTHER

RTECS: 9999999ZZ


INTERNALLY. KEEP OUT OF REACH OF CHILDREN.

RTECS: 9999999ZZ


HARMFUL OR FATAL. USE ONLY W/ADEQ VENT. AVOID BRTHG

RTECS: 9999999ZZ


HANDS AFTER USING. THIS COATING MAY CONTAIN MATLS

RTECS: 9999999ZZ


INGREDS WHICH MAY BE PRESENT AT HAZ LEVS ONLY DURING

RTECS: 9999999ZZ


DUSTS ARE LISTED IN INGREDS, APPLIC LIM FOR NUISANCE

RTECS: 9999999ZZ

Fraction By Weight: NO


15 MG/M3) TOTAL DUST; 5 MG/ML (RESPIRABLE FRACTION).

RTECS: 9999999ZZ


GENERATED FROM THIS PROD, UNDERLYING PAINT, OR

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:IRRIT TO EYES, SKIN & RESP SYS.
MAY CAUSE NERV SYS DEPRESS. EXTREME OVEREXP MAY RSLT IN UNCON &
POSSIBLY DEATH. SIGNS & SYMP OF OVEREXP:HDCH, DIZZ, NAUS, & LOSS OF
COORDINATION ARE INDICATIONS O F EXCESS EXPOS TO VAP/SPRAY MISTS.
REDNESS & ITCHING/BURNING SENSATION MAY INDICATE EYE/EXCESS SKIN
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:EXPOS. CHRONIC:PRLNGD OVEREXP TO SOLV
INGREDS MAY CAUSE ADVERSE EFTS TO LIVER, URINARY, BLOOD-FORMING,
CARDIOVASCULAR, & REPROD SYS. METHYL-ETHYL KETONE MAY INCREASE NERV
SYS EFTS OF OTHER SO LV. RPTS HAVE ASSOC RPTD & PRLNGD OVEREXP TO
SOLV W/PERM BRAIN & NERV SYS DAMAGE.
Medical Cond Aggravated by Exposure:NONE.

First Aid

First Aid:INHAL:REMOVE FROM EXPOSURE. RESTORE BRTHG. KEEP WARM & QUIET.
SKIN:WASH AREA THORO W/SOAP & WATER. REMOVE CONTAMD CLTHG & LAUNDER
BEFORE RE-USE. EYES:FLUSH W/LG AMTS OF WATER FOR @ LEAST 15 MINS.
GET MED ATTN. INGEST:GET MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:PMCC
Flash Point:<0F,<-18C
Lower Limits:0.9%
Upper Limits:13.1%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
WATER SPRAY MAY BE INEFTIVE. IF WATER IS USED, FOG NOZZ ARE PREF.
WATER MAY BE USED TO COOL CLSD CNTNRS(SUPDAT)
Unusual Fire/Explosion Hazard:ISOLATE FROM HEAT, ELEC EQUIP, SPARKS &
OPEN FLAME. CLSD CNTNRS MAY EXPLODE WHEN EXPOSED TO EXTREME HEAT.
APPLIC TO HOT SURF REQS SPEC PRECAUT. DURING (SUPDAT)

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE &
REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPARKS & OPEN
FLAME. VAPS WILL ACCUM READILY & MAY IGNITE EXPLOSIVELY. CONSULT
NFPA CODE. USE APPRVD BONDING & GROUNDING PROC.
Other Precautions:DURING USE & UNTIL ALL VAPS ARE GONE KEEP AREA VENT -
DO NOT SMOKE - EXTING ALL FLAMES, PILOT LIGHTS, & HEATERS - TURN
OFF STOVES, ELEC TOOLS & APPLIANCES, & ANY OTHER SOURCES OF IGNIT.
CONTENTS UNDER PRESS. DO NOT PUNCTURE, INCIN, (SUPDAT)

Exposure Controls

Respiratory Protection:IF PERSONAL EXPOS CANNOT BE CONTROLLED BELOW
APPLIC LIM BY VENT, WEAR NIOSH/MSHA APPRVD PROPERLY FITTIED ORG
VAP/PARTICULATE RESP. WHEN SANDING/ABRADING DRIED FILM, WEAR
NIOSH/MSHA APPRVD DUST/MIST RE SP FOR DUST WHICH MAY BE (ING 16)
Ventilation:LOC EXHAUST:PREFERRABLE. GENERAL:ACCEPTABLE.
Protective Gloves:CHEM RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORK GOGGS .
Other Protective Equipment:ANSI APPRVD EMER EYE BATH AND DELUGE SHOWER
.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MFR TRADE NAME/PART NO:TOUCH UP SPRAY COLORS. FIRE FIGHT PROC:TO PVNT
PRESS BUILD-UP & POSS AUTOIGNIT/EXPLO WHEN EXPOSED TO EXTREME HEAT.
EXPLO HAZ:EMER CNDTNS OVEREXP TO DECOMP PROD MAY CAUSE HLTH HA Z.
SYMP MAY NOT BE IMMED APPARENT. OBTAIN MED ATTN. OTHER PRECAUT:OR
EXPOSE TO TEMP ABOVE 120F. HEAT FROM (ING 9)

Chemical Properties

Boiling Pt:B.P. Text:<0F,<-18C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Evaporation Rate & Reference:FASTER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY FIRE:CARBON DIOXIDE, CARBON
MONOXIDE, OXIDES OF METALS IN INGREDIENTS.

Disposal

Waste Disposal Methods:WASTE MAY BE HAZ AS DEFINED UNDER RCRA 40 CFR
161. WASTE MUST BE TESTED FOR IGNITABILITY TO DETERM APPLIC EPA HAZ
WASTE NUMBERS. DO NOT INCIN. DEPRESSURIZE CNTNR. DISPOSE OF I/A/W
FED, ST, & LOCAL REG S REGARDING POLLUTION.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.