BXJXN - STAFOAM AA 1802 COMP 1
- MSDS: BXJXN
- Manufacturer: EXPANDED RUBBER AND PLASTIC CORP
- Product Name: STAFOAM AA 1802 COMP 1
- National Stock Number: 9330-01-121-7101
Product Identification
Product ID:STAFOAM AA 1802 COMP 1
MSDS Date:04/12/1995
FSC:9330
NIIN:01-121-7101
Kit Part:Y
MSDS Number: BXJXN
Responsible Party
GARDENA, CA 90249-3008
US
Emergency Phone: 800-424-9300 CHEMTREC
Info Phone: 213-321-4260 OR 213-324-6692
Preparer: UNREADABLE
Cage: 25598
Contractor
Telephone: 310-321-4260
Cage: 25598
Ingredients
TOLUENEDIISOCYANATE (MIXED ISOMERS) (SARA 313) (CERCLA)
CAS: 26471-62-5
RTECS: NQ9490000
Fraction By Weight: <80%
ACGIH TLV: 0.005PPM/0.02STEL;95
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
POLYETHER POLYOL
Fraction By Weight: >10%.
TRICHLOROFLUOROMETHANE (CFC-11) (SARA 313) (CERCLA)
CAS: 75-69-4
RTECS: PB6125000
Fraction By Weight: >9%
OSHA PEL 1000 PPM
ACGIH TLV: C, 1000 PPM; 9495
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
BENZOYL CHLORIDE (SARA 313) (CERCLA)
CAS: 98-88-4
RTECS: DM6600000
Fraction By Weight: <0.1%
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: VAPOR INHALATION MAY CAUSE
SEVERE RESPIRATORY TRACT IRRITATION. LIQUID CONTACT CAN CAUSE
SEVERE SKIN & EYE BURNS. CHRONIC: PROLONGED EXPOSURE MAY CAUSE
PULMONARY EDEMA, CHRONIC LUNG IMPAIRMENT.
Explanation of Carcinogenicity:NTP LISTS TOLUENE DIISOCYANATE (TDI) AS
AN ANTICIPATED CARCINOGEN; IARC LISTS IT AS A 2B OR POSSIBLE HUMAN
CARCINOGEN.
Effects of Overexposure:INHALED-ASTHMA-LIKE SYMPTOMS, COUGHING,
WHEEZING, SNEEZING, SHORTNESS OF BREATH, DIFFICULT OR LABORED
BREATHING. SKIN-REDNESS, BURNS, PAIN. EYES-REDNESS, PAIN, BURNS,
TEARING. INGESTED-NO DATA GIVEN.
Medical Cond Aggravated by Exposure:RESPIRATORY, BRONCHIAL CONDITIONS.
SKIN SENSITIVITY.
First Aid
First Aid:EYES-FLUSH WITH LOTS OF WATER FOR 15 MINUTES, LIFTING LIDS.
GET MEDICAL ATTENTION. SKIN-WASH WITH SOAP & WATER. REMOVE
CONTAMINATED CLOTHES. INGESTED-IF CONSCIOUS, GIVE LOTS OF WATER. DO
NOT INDUCE VO MITING! GET MEDICAL ATTENTION. INHALED-MOVE TO FRESH
AIR. GIVE OXYGEN IF NEEDED. GET MEDICAL ATTENTION.
Fire Fighting
Flash Point Method:PMCC
Flash Point:260F,127C
Lower Limits:0.9
Upper Limits:9.5
Extinguishing Media:WATER FOG, CARBON DIOXIDE OR FOAM.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS & FULL
PROTECTIVE GEAR.OXIDES OF CARBON & NITROGEN,TDI VAPORS,HYDROGEN
CHLORIDE, HYDROGEN CYANIDE & HF WILL BE FORMED.
Unusual Fire/Explosion Hazard:WATER CONTAMINATED MATERIAL WILL GENERATE
CARBON DIOXIDE WHICH MAY CAUSE EXPLOSIVE RUPTURE OF CLOSED
CONTAINERS WHEN EXPOSED TO FIRE CONDITIONS.
Accidental Release
Spill Release Procedures:CLEAN-UP CREW MUST WEAR PROPER PROTECTIVE
CLOTHING/EQUIPMENT. ABSORB MATERIAL WITH SAWDUST OR SWEEPING
COMPOUND. DECONTAMINATE WITH MIXTURE OF 90% WATER, 8% AMMONIA & 2%
DETERGENT. SHOVEL INTO OPEN TO P DRUMS & REMOVE TO WELL-VENTILATED
RAREA.
Neutralizing Agent:90% WATER, 8% AMMONIA, 2% DETERGENT SOLUTION.
Handling
Handling and Storage Precautions:STORE IN TIGHTLY CLOSED CONTAINERS IN
A DRY, COOL PLACE AT 75F.
Other Precautions:THIS PRODUCT REACTS WITH WATER AND OTHER SUBSTANCES
GENERATING CARBON DIOXIDE GASES. WILL CAUSE SEALDED CONTAINERS TO
EXPANDE AND POSSIBLY RUPTURE. DO NOT RESEAL CONTAINERS IF
CONTAMINATION IS SUSPECT ED.
Exposure Controls
Respiratory Protection:IF ENGINEERING CONTROLS FAIL OR NON-ROUTINE USE
OR AN EMERGENCY OCCURS; WEAR AN MSHA/NIOSH APPROVED RESPIRATOR OR
AN AIR-SUPPLIED RESPIRATOR OR SCBA, AS REQUIRED. USE IN ACCORDANCE
WITH 29 CFR 1910.13 4 AND MANUFACTURER'S RECOMMENDATIONS.
Ventilation:USE ADEQUATE MECHANICAL VENTILATION OR LOCAL EXHAUST TO
MAINTAIN EXPOSURE BELOW TLV(S).
Protective Gloves:RUBBER OR PLASTIC (BUTYL, PVA, VITON).
Eye Protection:SAFETY GLASSES/CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:COVERALLS, BOOTS, RUBBER APRONS. DLA-HMIS:
EYE WASH STATION & SAFETY SHOWER AVAILABLE.
Work Hygienic Practices:WASH HANDS AFTER HANDLING AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health
KEY1=T3. DO NOT EAT, DRINK OR SMOKE IN WORK AREAS. KEEP CLOTHING AND
EQUIPMENT CLEAN AT ALL TIMES. BREATHING VAPOR OF HOT MATERIAL CAN
BE EXTREMELY DANGEROUS.
Chemical Properties
HCC:T3
Boiling Pt:B.P. Text:75.0F,23.9C
Vapor Density:6.0
Spec Gravity:1.2
Appearance and Odor:LIGHT YELLOW, MEDIUM VISCOSITY LIQUID; PUNGENT
ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
BASIC COMPOUNDS, CAUSTIC SODA, TERTIARY AMINES, WATER.
Stability Condition to Avoid:TEMPERATURES ABOVE 75F FOR EXTENDED
PERIODS OF TIME.
Hazardous Decomposition Products:ISOCYANATE VAPORS, OXIDES OF CARBON &
NITROGEN, HYDROGEN CYANIDE, HYDROGEN CHLORIDE, HYDROGEN FLUORIDE.
Conditions to Avoid Polymerization:WATER & OTHER PRODUCTS THAT REACT
WITH ISOCYANATES.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL ENVIRONMENTAL REGULATIONS. SARA 313-YES, TOLUENE
DIISOCYANATE, CAS# 26471-62-5, 64%. CERCLA-RQ=100 LBS (TDI). SARA
302-NO (TDI).
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.